Hatco IMPERIAL "S manual Stpc Stpcw

Page 15

SPECIFICATIONS

BOOSTER HEATER SIZING CHART (CONTINUED)

 

 

ELECTRIC

ELECTRIC

 

 

COMPACT BOOSTER

IMPERIAL BOOSTER

Dishwasher

Model Number

Temperature Rise

Temperature Rise

 

 

40°F (22°C)

70°F (39°C)

40°F (22°C)

70°F (39°C)

 

 

 

 

 

 

Stero

SCT-44-10-LW, SCT-44-LW, SCT-66S-LW, SCT-76S-LW,

 

 

 

 

 

SCT-76SC-LW, SCT-90S-LW

. . .C-12 . . . .

. . .C-24 . . .

. . .S-12 . . .

. . .S-24

 

SC-1-2-4-LW, SC-1-6-4-LW, SC-2-4-LW, SC-5-2-4-LW,

 

 

 

 

 

SC-5-6-4-LW, SC-6-4-LW

. . .C-24 . . . .

. . .C-45 . . .

. . .S-24 . . .

. . .S-45

 

SCT-64, SCT-86S, SCT-94S, SCT-94SC

. . .C-24 . . . .

. . .C-39 . . .

. . .S-24 . . .

. . .S-39

 

SCT-108S, SCT-108SC, SCT-76, SCT-94SM

. . .C-27 . . . .

. . .C-54 . . .

. . .S-27 . . .

. . .S-54

 

SC-6-4, SCT-44, SCT-44-10, SCT-66S, SCT-76S,

 

 

 

 

 

SCT-76SC, SCT-90S

. . .C-30 . . . .

. . .C-54 . . .

. . .S-30 . . .

. . .S-54

 

SCT-120S, SCT-120SC, SCT-120SM, SCT-150SM

. . .C-36 . . . .

. . .C-57 . . .

. . .S-36 . . .

. . .S-57

 

STW-110, SC-1-2-7-4, SC-1-6-3-4, SC-1-6-7-4, SC-2-7-4,

 

 

 

 

 

SC-5-2-7-4, SC-5-6-3-4, SC-5-6-7-4, SC-6-3-4, SC-6-7-4

. . .C-39 . . . .

. .(2)C-36 . .

. . .S-39 . . . . .(2)S-39

 

SC-1-2-4, SC-1-6-4, SC-2-4, SC-5-2-4, SC-5-6-4

. . .C-45 . . . .

. .(2)C-36 . .

. . .S-45 . . . . .(2)S-45

 

SCT-44-10-SC-1-3-4, SCT-44-10-3-4, SCT-44-SC-1-3-4,

 

 

 

 

 

SCT-44-SC-3-4, SCT-54-SC-1-3-4, SCT-54-SC-3-4,

 

 

 

 

 

SCT-76S-SC-3-4

. . .C-45 . . . .

. .(2)C-36 . .

. . .S-40 . . . . .(2)S-36

 

STPC (Four tank)

. . .C-24 . . . .

. . .C-39 . . .

. . .S-24 . . .

. . .S-39

 

STPCW (Four tank)

. . .C-24 . . . .

. . .C-45 . . .

. . .S-24 . . .

. . .S-40

 

STPC

. . .C-27 . . . .

. . .C-54 . . .

. . .S-27 . . .

. . .S-54

 

STPCW

. . .C-36 . . . .

. .(2)C-30 . .

. . .S-36 . . . . .(2)S-30

 

SCBT

. . .C-45 . . . .

. .(2)C-36 . .

. . .S-40 . . . . .(2)S-36

 

SF-1RA, SC20-1

. . .C-7

. . .C-12 . . . .

. . .S-7 . . . .

. . .S-12

 

SF-2RA, SF-2DRA, SD-2RA, SDRA, SDRA-PACK

. . .C-12 . . . .

. . .C-18 . . .

. . .S-12 . . .

. . .S-18

 

SCT-54, SCT-76SM

. . .C-36 . . . .

. . .C-57 . . .

. . .S-36 . . .

. . .S-57

 

SCT-76, SCT-80, SCT-94, SCT-108, SCT-120

. . .C-45 . . . .

. . .C-57 . . .

. . .S-45 . . .

. . .S-57

 

U-31-A, U-31-AC

. . . .---

. . . .--- . . . .

. . .S-18 . . .

. . .S-36

 

U-31-A2

. . .C-45 . . . .

. .(2)C-36 . .

. . .S-45 . . . . .(2)S-36

 

STBUW-14

. . .C-57 . . . .

. .(2)C-54 . .

. . .S-57 . . . . .(2)S-54

 

SC-2-3-4, SC-5-2-3-4

. . .C-30 . . . .

. .(2)C-27 . .

. . .S-30 . . . . .(2)S-27

 

SC20-2

. . .C-12 . . . .

. . .C-24 . . .

. . .S-12 . . .

. . .S-24

 

SC-2-8, SC-2-9, SC-1-2-8, SC-5-6-8, SC-6-8, SC-6-9,

 

 

 

 

 

SC-1-6-8, SC-5-6-9, SC-5-2-9, SC-1-6-9, SC-5-2-8

. . .C-18 . . . .

. . .C-36 . . .

. . .S-18 . . .

. . .S-36

*Hobart Model AM-12 with serial no. 12-067-357 or below and model AM-12C with serial no. 12-067-537 or below require slightly larger booster than listed.

Or C Models with serial no. 85-1041605 or greater use Opti-RinSe. Shaded area indicates older models prior to Opti-RinSe.

This selector chart is based on 40°F (22°C) and 70°F (39°C) temperature rises, 20 psi flow pressure, and minimum rinse cycle timer setting in NSF listing.

All booster heaters are rated at 100% of the capacity of the dishwashers as recommended by the National Sanitation Foundation. Where make-up water for wash tank is provided from final rinse supply, chart recommendations are based upon this additional demand (not over 2 GPM) as required by NSF.

All sizings shown are that of the dishwasher manufacturers. Hatco Corporation is not responsible for incorrect sizing applications.

13

Form No. EBOOSTERM-0406

Image 15
Contents Electric Booster Water Heaters Contents Important Owner InformationIntroduction Important Safety Information Important Safety Information Important Safety Information Compact Models C Series Model DescriptionsALL Models Imperial Models S SeriesCircuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kW SpecificationsFuse Size Wire Size Volts Phase Amp Draw Breaker or Copper N d u i tCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Boosters Rated AT 30F 16C Rise Sizing Chart for LOW-TEMP DishmachinesSpecifications Electric Compact Booster Imperial Booster Booster Heater Sizing ChartWM-5C FW4 Stpc Stpcw Capacity MINI-COMPACT MC Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Imperial S Series Capacity Compact C SeriesDimensions Imperial S Series Installation Dimensions MINI-COMPACT MC SeriesLocation Installing Legs Mounting Brackets with Hardware Temperature/Pressure GaugeTemperature Pressure Relief Valve Leg Pressure Reducing ValveFor Installing Pressure Pressure and Temperature Relief ValvesPlumbing Connections TEMPERATURE/PRESSURE GaugesPressure Reducing Valve Blended Phosphate Water Treatment System OptionalRefer to , 9, 10, 11 or InletPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet General ELECTRICAL-ALL Sizes and VoltagesOperation System START-UPShut Down General MaintenanceHigh Temperature Limit Safety Switch Thermostat AdjustmentBlended Phosphate Treatment System Optional Shock Absorber AccessoriesStainless Steel Adjustable Legs Floor Mounting HardwareTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Product Warranty Hatco Limited WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors