Hatco IMPERIAL "S manual Maintenance, General, Thermostat, High Temperature Limit Safety Switch

Page 29

MAINTENANCE

GENERAL

WARNING

To avoid any injury or damage to the booster heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance or adjustments.

THERMOSTAT

Thermostat Adjustment

The thermostat is factory calibrated to produce temperatures of 185°-190°F (85°-88°C). If adjustment or recalibration is required use the following procedure. (See Figures 18 and 19.)

NOTE: Low Temperature Dishmachines require the thermostat(s) to be adjusted to 140°-150°F (60°-66°C).

1.Remove the access cover.

To lower the temperature setpoint, turn the outer adjustment screw counterclockwise.

To raise the temperature setpoint, turn the outer adjustment screw clockwise.

NOTE: 1/6 turn of the outer screw equals 12°F (6.7°C).

If recalibration is necessary, with the outer screw at high stop turn inner adjustment screw clockwise to raise the set point.

NOTE: 1/6 turn of the inner screw equals 8°F (4.4°C).

HIGH TEMPERATURE LIMIT SAFETY SWITCH

All Hatco Electric Booster Water Heaters are equipped with a manually reset high temperature limit safety switch. If the temperature of the water in the heater exceeds 210°F (99°C) the safety switch will shut off the power. The switch must be manually reset by pushing the red button.

If the high temperature limit safety switch needs to be reset use the following procedure (See Figures 18 and 20.):

1.Remove access cover.

2.Push red reset button.

3.If tripping repeats, call an Authorized Service Agent.

Access Cover

Figure 18. Access Cover for Thermostat(s) and High

Temperature Limit Safety Switch

Outer Screw

Inner Screw

Figure 19. Thermostat Adjustment

Red Reset Button

Figure 20. High Temperature Limit Safety Switch

27

Form No. EBOOSTERM-0406

Image 29
Contents Electric Booster Water Heaters Introduction ContentsImportant Owner Information Important Safety Information Important Safety Information Important Safety Information ALL Models Model DescriptionsImperial Models S Series Compact Models C SeriesCircuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kW SpecificationsFuse Size Wire Size Volts Phase Amp Draw Breaker or Copper N d u i tCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Boosters Rated AT 30F 16C Rise Sizing Chart for LOW-TEMP DishmachinesSpecifications Electric Compact Booster Imperial Booster Booster Heater Sizing ChartWM-5C FW4 Stpc Stpcw Capacity Imperial S Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Compact C Series Capacity MINI-COMPACT MC SeriesDimensions Imperial S Series Location InstallationDimensions MINI-COMPACT MC Series Installing Legs Temperature Pressure Relief Valve Temperature/Pressure GaugeLeg Pressure Reducing Valve Mounting Brackets with HardwareFor Installing Pressure Pressure and Temperature Relief ValvesPressure Reducing Valve TEMPERATURE/PRESSURE GaugesBlended Phosphate Water Treatment System Optional Plumbing ConnectionsRefer to , 9, 10, 11 or InletPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet General ELECTRICAL-ALL Sizes and VoltagesShut Down OperationSystem START-UP High Temperature Limit Safety Switch MaintenanceThermostat Adjustment GeneralBlended Phosphate Treatment System Optional Stainless Steel Adjustable Legs AccessoriesFloor Mounting Hardware Shock AbsorberTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Product Warranty Hatco Limited WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors