Hatco IMPERIAL "S manual Circuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW

Page 9

SPECIFICATIONS

CIRCUIT BREAKER & FUSED DISCONNECT SWITCH SIZES - 36 to 57 kW

 

kW

Volts*

Phase

 

Amp Draw

 

 

Breaker or

Copper

C o n d u i t

 

 

 

 

L1

 

L2

 

L3

 

Fuse Size

Wire Size

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

36

208

1

173

 

173

 

-

225

4/0

1-1/2" (38 mm)

 

 

208

3

100

 

100

 

100

125

1

1-1/4" (32 mm)

 

 

240

1

150

 

150

 

-

200

3/0

1-1/2" (38 mm)

 

 

240

3

86.7

 

86.7

 

86.7

125

1

1-1/4" (32 mm)

 

 

380

3

54.7

 

54.7

 

54.7

70

4

1" (25 mm)

 

 

480

3

43.3

 

43.3

 

43.3

60

6

3/4" (19 mm)

 

 

600

3

34.7

 

34.7

 

34.7

50

8

1/2" (13 mm)

 

39

208

1

187.5

 

187.5

 

-

250

250 kcmil

2" (51 mm)

 

 

208

3

108

 

108

 

108

150

1/0

1-1/4" (32 mm)

 

 

240

1

163.5

 

163.5

 

-

225

4/0

2" (51 mm)

 

 

240

3

94

 

94

 

94

125

1

1-1/4" (32 mm)

 

 

380

3

59.3

 

59.3

 

59.3

90

3

1" (25 mm)

 

 

480

3

47

 

47

 

47

60

6

3/4" (19 mm)

 

 

600

3

37.6

 

37.6

 

37.6

50

8

1/2" (13 mm)

40

380

3

61.6

 

61.6

 

61.6

90

3

1" (25 mm)

40.5

208

3

112.5

 

112.5

 

112.5

150

1/0

1-1/4" (32 mm)

 

 

240

3

97.5

 

97.5

 

97.5

125

1

1-1/4" (32 mm)

 

 

480

3

48.8

 

48.8

 

48.8

70

4

1" (25 mm)

 

 

600

3

39

 

39

 

39

50

8

3/4" (19 mm)

45

208

3

125

 

125

 

125

175

2/0

1-1/2" (38 mm)

 

 

240

1

188

 

188

 

-

250

250 kcmil

2" (51 mm)

 

 

240

3

108

 

108

 

108

150

1/0

1-1/4" (32 mm)

 

 

380

3

68.6

 

68.6

 

68.6

90

3

1" (25 mm)

 

 

480

3

54

 

54

 

54

70

4

1" (25 mm)

 

 

600

3

43.4

 

43.4

 

43.4

60

6

3/4" (19 mm)

54

208

3

150

 

150

 

150

200

3/0

2" (51 mm)

 

 

240

3

130

 

130

 

130

175

2/0

1-1/2" (38 mm)

 

 

380

3

82.0

 

82.0

 

82.0

125

1

1-1/4" (32 mm)

 

 

480

3

65

 

65

 

65

90

3

1" (25 mm)

 

 

600

3

52

 

52

 

52

70

4

1" (25 mm)

57

208

3

158.4

 

158.4

 

158.4

225

4/0

2" (51 mm)

 

 

240

3

137.3

 

137.3

 

137.3

200

3/0

2" (51 mm)

 

 

380

3

86.7

 

86.7

 

86.7

125

1

1-1/4" (32 mm)

 

 

480

3

68.6

 

68.6

 

68.6

90

3

1" (25 mm)

 

 

600

3

54.9

 

54.9

 

54.9

70

4

1" (25 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire size is based on THHN wire for branch circuit protection at .91 derate factor. Circuit breakers and fused disconnects are to be mounted remote and wired by contractor. Sizes are based on the 2002 NEC table 310-16. Conduit size based on conductors plus ground wire sizing per Table C1 from Appendix C.

Only 6, 7 & 9 kW models can be field converted to single or three phase (open delta on 3 phase). Larger branch circuit required than for balanced 3 phase of equal kW. Balanced 3 phase available, consult factory.

NOTE: 250 kcmil maximum wire size for terminal block.

7

Form No. EBOOSTERM-0406

Image 9
Contents Electric Booster Water Heaters Contents Important Owner InformationIntroduction Important Safety Information Important Safety Information Important Safety Information ALL Models Model DescriptionsImperial Models S Series Compact Models C SeriesCircuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kW SpecificationsFuse Size Wire Size Volts Phase Amp Draw Breaker or Copper N d u i tCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Boosters Rated AT 30F 16C Rise Sizing Chart for LOW-TEMP DishmachinesSpecifications Electric Compact Booster Imperial Booster Booster Heater Sizing ChartWM-5C FW4 Stpc Stpcw Capacity Imperial S Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Compact C Series Capacity MINI-COMPACT MC SeriesDimensions Imperial S Series Installation Dimensions MINI-COMPACT MC SeriesLocation Installing Legs Temperature Pressure Relief Valve Temperature/Pressure GaugeLeg Pressure Reducing Valve Mounting Brackets with HardwareFor Installing Pressure Pressure and Temperature Relief ValvesPressure Reducing Valve TEMPERATURE/PRESSURE GaugesBlended Phosphate Water Treatment System Optional Plumbing ConnectionsRefer to , 9, 10, 11 or InletPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet General ELECTRICAL-ALL Sizes and VoltagesOperation System START-UPShut Down High Temperature Limit Safety Switch MaintenanceThermostat Adjustment GeneralBlended Phosphate Treatment System Optional Stainless Steel Adjustable Legs AccessoriesFloor Mounting Hardware Shock AbsorberTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Product Warranty Hatco Limited WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors