SPECIFICATIONS
DIMENSIONS - MINI-COMPACT “MC” SERIES
INSTALLATION
LOCATION
For the most effective operation, install the booster heater as close as possible to the commercial dishwasher. The location must have a solid foundation along with being clean and dry. Adequate front clearance is required to allow for accessibility to the control compartment. Location must have adequate clearance to allow for inspection, testing or replacement of pressure/temperature relief valve.
WARNING
To avoid any injury or damage do not install the unit in an area where flammable liquids or combustible vapors are present.
WARNING
To avoid personal injury and to assure safe operation install the booster heater as close as possible to the commercial dishwasher. Employ recirculation if distance between booster and commercial dishwasher exceeds National Sanitation Foundation (NSF) specifications of five (5) linear feet (1524 mm).
WARNING
To avoid personal injury or damage to equipment, the booster heater must be installed by qualified, trained installers. Installation must conform to all local electrical and plumbing codes. Check with your local plumbing and electrical inspectors for proper procedures and codes.
CAUTION
Unit is not weatherproof. For safe and proper operation the unit must be located indoors where the ambient air temperature is constant and is a minimum of 70°F (21°C).