MAINTENANCE

BLENDED PHOSPHATE TREATMENT SYSTEM (OPTIONAL)

The Blended Phosphate Water Treatment System reduces mineral scale by introducing a measured amount of polyphosphate into the water. Cartridges supplied have a usage rating of 100,000 gallons (378,541 liters) of water. When the cartridge is depleted use the following procedure for replacement:

1.Shut off electrical power to the heater.

2.Shut off water supply and open drain valve to remove water in piping.

3.Loosen canister using wrench attached.

4.Remove canister and discard depleted cartridge.

5.Using a clean damp cloth, wipe interior of canister clean.

NOTE: Make sure O-ring seal is properly placed in canister.

6. Reverse procedure to reinstall.

WARNING

If service is required on this unit, contact your Authorized Hatco Service Agent, or contact the Hatco Service Department at 800-558-0607 or 414-671-6350; fax 800-690-2966 or International fax 414-671-3976.

WARNING

This product has no “user” serviceable parts. To avoid damage to the unit or injury to personnel, use only Authorized Hatco Service Agents and Genuine Hatco Replacement Parts when service is required.

WARNING

Genuine Hatco Replacement Parts are specified to operate safely in the environments in which they are used. Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment. It is essential to use Hatco Replacement Parts when repairing Hatco equipment. Failure to use Hatco Replacement Parts may subject operators of the equipment to hazardous electrical voltage, resulting in electrical shock or burn.

Form No. EBOOSTERM-0406

28

Image 30
Contents Electric Booster Water Heaters Contents Important Owner InformationIntroduction Important Safety Information Important Safety Information Important Safety Information Imperial Models S Series Model DescriptionsALL Models Compact Models C SeriesSpecifications Circuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kWVolts Phase Amp Draw Breaker or Copper N d u i t Fuse Size Wire SizeCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Sizing Chart for LOW-TEMP Dishmachines Boosters Rated AT 30F 16C RiseSpecifications Booster Heater Sizing Chart Electric Compact Booster Imperial BoosterWM-5C FW4 Stpc Stpcw Capacity Compact C Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Imperial S Series Capacity MINI-COMPACT MC SeriesDimensions Imperial S Series Installation Dimensions MINI-COMPACT MC SeriesLocation Installing Legs Leg Pressure Reducing Valve Temperature/Pressure GaugeTemperature Pressure Relief Valve Mounting Brackets with HardwarePressure and Temperature Relief Valves For Installing PressureBlended Phosphate Water Treatment System Optional TEMPERATURE/PRESSURE GaugesPressure Reducing Valve Plumbing ConnectionsInlet Refer to , 9, 10, 11 orPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet ELECTRICAL-ALL Sizes and Voltages GeneralOperation System START-UPShut Down Thermostat Adjustment MaintenanceHigh Temperature Limit Safety Switch GeneralBlended Phosphate Treatment System Optional Floor Mounting Hardware AccessoriesStainless Steel Adjustable Legs Shock AbsorberTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Hatco Limited Warranty Product WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors