Hatco IMPERIAL "S manual Installing Legs

Page 19

INSTALLATION

ALL MODELS

Booster Heaters are shipped with most components pre-assembled. Care should be taken when unpacking shipping carton to avoid damage to unit and components enclosed. Components are shipped with the heater unit. (See Figure 7.)

1.Remove unit from box.

2.Remove information packet. To prevent delay in obtaining warranty coverage, fill out and mail in the warranty card to Hatco.

3.Remove tape and protective packaging from all surfaces of unit.

4.If your unit is equipped with legs, carefully lay unit on its side and install the four legs as shown in Figure 4.

CAUTION

Do not lay unit on the side with the control panel or damage to unit could occur.

NOTE: If unit is not level, use an adjustable open- end wrench to adjust the foot of each leg until unit is level. Each leg is adjustable from 6" (152 mm) to 7" (178 mm).

5.On Compact Series, when installing unit with mounting brackets, space slide rails as shown in Figure 5 and weld rails to bottom of dishtable.

WARNING

To avoid personal injury or damage to the equipment make sure the dishtable is strong enough to support the weight of the booster heater and water when installing with slide mounting brackets.

WARNING

To avoid personal injury or damage to the equipment, follow standard welding procedures when attaching sliderails to bottom of dishtable.

6.Using Hatco slide brackets as a template, drill 1/8" (3 mm) holes into the sides of the heater jacket.

7.Attach slide brackets to sides of heater with 3/4 x 8 sheet metal screws supplied. (See Figure 5.)

8.Slide heater onto slide rails under dishtable. (See Figure 6.)

Figure 4. Installing Legs

Weld slide rail to bottom of dish table

Fasten slide brackets to booster heater sides

Figure 5. Hanging Support

Figure 6. Compact Series Heater Mounted to Dishtable

17

Form No. EBOOSTERM-0406

Image 19
Contents Electric Booster Water Heaters Important Owner Information ContentsIntroduction Important Safety Information Important Safety Information Important Safety Information Compact Models C Series Model DescriptionsALL Models Imperial Models S SeriesCircuit Breaker & Fused Disconnect Switch Sizes 4 to 12 kW SpecificationsFuse Size Wire Size Volts Phase Amp Draw Breaker or Copper N d u i tCircuit Breaker & Fused Disconnect Switch Sizes 36 to 57 kW Boosters Rated AT 30F 16C Rise Sizing Chart for LOW-TEMP DishmachinesSpecifications Electric Compact Booster Imperial Booster Booster Heater Sizing ChartWM-5C FW4 Stpc Stpcw Capacity MINI-COMPACT MC Series Model 40F 22C Rise 70F 39C Rise Shipping WeightCapacity Imperial S Series Capacity Compact C SeriesDimensions Imperial S Series Dimensions MINI-COMPACT MC Series InstallationLocation Installing Legs Mounting Brackets with Hardware Temperature/Pressure GaugeTemperature Pressure Relief Valve Leg Pressure Reducing ValveFor Installing Pressure Pressure and Temperature Relief ValvesPlumbing Connections TEMPERATURE/PRESSURE GaugesPressure Reducing Valve Blended Phosphate Water Treatment System OptionalRefer to , 9, 10, 11 or InletPlumbing Connections Imperial S Series Form No. EBOOSTERM-0406 Outlet General ELECTRICAL-ALL Sizes and VoltagesSystem START-UP OperationShut Down General MaintenanceHigh Temperature Limit Safety Switch Thermostat AdjustmentBlended Phosphate Treatment System Optional Shock Absorber AccessoriesStainless Steel Adjustable Legs Floor Mounting HardwareTroubleshooting Symptom Probable Cause Corrective Action Troubleshooting Troubleshooting Product Warranty Hatco Limited WarrantyForm No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Form No. EBOOSTERM-0406 Hatco Authorized Parts Distributors