Superior DR-400CEN Table F, V Minimum, H Maximum, H+H1 Maximum, Top Vent - ONE 90 DEGREE ELBOW

Page 17
TABLE F

HORIZONTAL VENT FIGURES/TABLES (CONTINUED)

TABLE F

 

V = 0ne 90 degree elbow

H

H = 3 feet (0.914 m) Max.

 

V

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

*Wall Firestop/Spacer

(SV4.5HF)

*When using Secure Flex, use Wall Firestop/Spacer SV4.5HF.

Figure 36 - Top Vent - ONE 90 DEGREE ELBOW - ELBOW CONNECTION AT APPLIANCE

TABLE G

V Minimum

H Maximum

feet

(m)

feet

(m)

1

(0.305)

5

(1.52)

2

(0.61)

10

(3.1)

3

(0.914)

15

(4.65)

4

(1.22)

20

(6.2)

V + H = 40 feet (12.4 m) Max.

H = 20 feet (6.2 m) Max.

Refer to Table 3 on page 16 for an aid in venting component selection for a particular range of exterior wall thicknesses when using the square (SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

TABLE H

V Minimum

H Maximum

H+H1 Maximum

feet

(m)

feet

(m)

feet

(m)

 

 

 

 

 

 

1

(0.305)

2

(0.610)

5

(1.52)

 

 

 

 

 

 

2

(0.610)

4

(1.22)

10

(3.1)

 

 

 

 

 

 

3

(0.914)

6

(1.86)

15

(4.65)

 

 

 

 

 

 

4

(1.22)

8

(2.48)

20

(6.2)

 

 

 

 

 

 

V+H+H1 = 40 feet (12.4 m) Max.

H = 8 feet (2.48 m) Max.

H + H1 = 20 feet (6.2 m) Max.

Refer to Table 3 on page 16 for an aid in venting component selection for a particularrangeofexteriorwallthicknesseswhenusingthesquare(SV4.5HTS), small square (SV4.5HTSS) or the round (SV4.5HTR) termination .

Short Square Termination (SV4.5HTSS) shown;

Long Square Termination (SV4.5HTSSL) may also be used; Square Termination (SV4.5HTS) may also be used Round Termination (SV4.5HTR) may also be used.

*When using Secure Flex, use Wall Firestop/Spacer

SF4.5HF.

H

H1

H

*Wall

V

*Wall Firestop/Spacer

(SV4.5HF)

**Ceiling Firestop/Spacer

(SV4.5BF)

**When using Secure Flex, use Ceiling

Firestop/Spacer SF4.5BF.

Figure 37 - Top Vent - ONE 90 DEGREE ELBOW -

ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE

Firestop/Spacer

(SV4.5HF)

**Ceiling

H+H1 Maximum Firestop/Spacer

(SV4.5BF)

*When using Secure

 

*Wall

Flex, use Wall

 

Firestop/Spacer

V

Firestop/Spacer

SF4.5HF.

 

(SV4.5HF)

**When using Secure

Flex, use Ceiling Firestop/Spacer SF4.5BF.

Figure 38- Rear Vent - TWO 90 DEGREE ELBOWS

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

17

Image 17
Contents DIRECT VENT DT-400& DR-400 INSTALLATION INSTRUCTIONSMODELS Millivolt ElectronicPACKAGING TYPICAL INSTALLATIONINTRODUCTION GENERAL INFORMATIONMillivolt Models ÀCOTE DE LAPPAREILElectronic Models All ModelsLOCATION Typical LocationsAPPLIANCE AND VENT CLEARANCES Shelf Height inches mmDETAILED INSTALLATION STEPS TYPICAL INSTALLATION SEQUENCEVENT TERMINATION CLEARANCES Vertical Vent Termination ClearancesUS Installation Canadian Installation12 inches 30cm 12 inches 30cmAND ROUND HORIZONTAL TERMINATION SV4.5HTR framing depth dimension when the finish12¹⁄₈material drywall thickness is 1/2 in 13mmStep 3. INSTALL THE VENT SYSTEM FIREPLACE SPECIFICATIONSway. Install vent according to local codes listed for operation and installation withSelect Venting System - Horizontal or Vertical Vertical Straight InstallationVERTICAL TERMINATION SYSTEMS ROOF Vent / Appliance Collar Connection Vertical Offset InstallationC. Attach vent components to each other ConnectionPitch Framing Dimensions for Roof0/12 6/12VERTICAL VENT FIGURES/TABLES TABLE AH Maximum Figure 23 - Top Vent - STRAIGHTVERTICAL VENT FIGURES/TABLES TABLE DFigure 26 - Rear Vent - THREE ELBOWS Figure 27 - Top Vent - THREE ELBOWSTYPICAL HORIZONTAL VENT INSTALLATION F.Install firestop/spacer at ceilingHORIZONTAL OUTSIDE WALL TERMINATION SYSTEM A. Plan the vent runattach termination adapter Connecting/Recessing Long Square HorizontalSquare SV4.5HTS Short Square SV4.5HTSSHORIZONTAL VENT FIGURES/TABLES 3.Install the round termination SV4.5HTRVenting Components LONG SQUARE TERMINATIONV Minimum TABLE FH Maximum V MinimumTABLE J HORIZONTAL VENT FIGURES/TABLE CONTINUEDH + H1 Maximum termination Figure 39- Top Vent - TWO 90 DEGREE ELBOWSC. Route Flex Vent A. Install the Inner Flex PipeB. Install the Outer Flex Pipe B. Electronic Wiring See Figure Step 4. FIELD WIRINGA. SIT and Honeywell Millivolt Wiring Optional Gas Flex Line Connector Step 6. CONNECTING GAS LINEFBK-250Blower Kit See Figure Opening Control Compartment DoorStep 9. INSTALLING THE GLASS DOOR Step 7. INSTALLING LOGS AND GLOWING EMBERSAdjustment Sit and Honeywell Millivolt Gas ValveStep 11. HOOD INSTALLATION Step 10. BURNER ADJUSTMENTSBurner Adjustment FINISHING REQUIREMENTS Wall DetailsMANTEL CLEARANCES INSTALLATION ACCESSORIESInches mm COLD CLIMATE INSULATIONModel No. Description INSTALLATION ACCESSORIES ContinuedDescription GAS CONVERSION KITS AND .2 INSTALLATION CODEIn Canada Natural To Propane Gas Conversion Kit SIT SystemsPilot for SIT Millivolt Gas Valve Pilot Orifice Adjusting KnobPilot for Honeywell Millivolt Gas Valve Step 5. Millivolt Appliances Honeywell SystemsPilot PilotAssembly Orifice Ignitor Assembly Spring Adjusting ScrewAll Models Model No