Superior DR-400CMP Fireplace Specifications, Install The Vent System, directly to the outside

Page 8
FIREPLACE SPECIFICATIONS

8

FIREPLACE SPECIFICATIONS

 

 

 

 

 

 

FRAMING

 

21¹⁄₂

 

 

(Louvered Front Model Shown)

 

 

 

SPACERS

10³⁄₄

(546)

 

 

 

 

 

 

(Top and Sides

 

 

 

*CONCENTRIC FLUE

 

 

 

and Rear)

(273)

 

 

FLUE - 4¹⁄₂ (114)

 

 

 

 

 

 

 

 

COMBUSTION AIR - 7¹⁄₂ (190)

 

 

 

 

 

 

 

 

 

Inches (millimeters)

 

 

 

 

 

*DR models have only a rear vent

 

 

 

 

 

 

 

6¹³⁄₁₆

*DT models have only a top vent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(173)

 

 

 

 

 

Top View

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

33¹⁄₈

 

3 (76)

NOTE - Eyebrow

(330)

 

 

 

 

 

hood shown as positioned

 

¹⁄₂ (13)

 

 

 

(841)

 

 

in louvered front model.

 

 

 

 

 

 

 

ELECTRICAL INLET

 

 

 

1

 

 

 

 

2³⁄₄ x 2 (70 x 51)

 

 

 

 

 

 

 

COVER PLATE with

 

 

 

(25)

 

 

 

 

 

 

 

 

 

 

 

KNOCKOUT)

 

 

 

 

 

 

 

 

 

 

 

33¹⁄₈

 

 

17

30¹⁄₈

GAS INLET

 

1 (25)

 

 

27¹⁄₂

(432)

(765)

8¹¹⁄₃₂

 

**19⁵⁄₈

(841)

 

(Either Side

 

 

 

 

(212)

 

 

(699)

 

 

1⁵⁄₈

 

 

 

 

and bottom)

 

(498)

 

 

 

 

 

3 (76)

 

(42)

 

 

 

 

 

 

 

 

 

 

Front View

 

 

 

2³⁄₄ **Rear vent models only

 

 

Right Side View

(70)

 

Figure 11

 

 

 

 

 

 

 

 

Step 3. INSTALL THE VENT SYSTEM

DO NOT use any other manufacturer's

VENT RESTRICTOR INSTALLATION

General Information

 

 

 

vent components with these appli-

 

(TOP VENT)

 

 

 

ances. These fireplaces must be vented

In all venting applications using the top vent of

 

 

 

 

 

 

 

 

directly to the outside.

the appliance, a vent restrictor may be

These instructions should be used as a guide-

needed. Install the vent restrictor in the top

 

 

line and do not supersede local codes in any

The vent system

may not service multiple

 

vent of the appliance outlet.

way. Install vent according to local codes,

If needed, install the restrictor orientated as

appliances, and must never be connected to a

these instructions, the current National Fuel

shown, either from inside or outside the unit,

flue serving a solid fuel burning appliance. The

Gas Code (ANSI-Z223.1) in the USA or the

 

in the inner fireplace collar.

vent pipe is tested to be run inside an enclos-

 

 

 

current standards of CAN/CGA-B149.1 and -

RESTRICTOR

 

ing wall (such as a chase). There is no require-

 

B149.2 in Canada.

 

 

 

 

 

 

 

 

 

 

 

 

 

ment for inspection openings in the enclosing

 

 

 

 

 

 

 

 

 

 

These fireplaces are designed, tested and

wall at any of the joints in the vent pipe.

 

 

 

 

 

 

 

 

listed for operation and installation with,

Preparing the Appliance Top Vent Outlet in

INNER

 

and only with, Secure Vent

(SV 4.5)

 

All Venting Applications Using the Appliance

FIREPLACE

 

Direct Vent System Components, Secure

 

Top Vent Outlet

 

COLLAR

 

 

 

 

 

 

 

 

FlexFlexible Vent Components manu-

 

 

 

APPLIANCE TOP VENT OUTLET

factured by Security Chimneys Interna-

A vent restrictor

may be needed with this

Figure 12

 

tional. These approved vent system com-

appliance. Install the vent restrictor (provided)

 

 

 

 

ponents are labeled for identification.

in the appliance top flue outlet as shown in

 

 

 

 

 

 

 

Figure 12. It is held in place by friction, only.

 

 

 

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 8
Contents INSTALLATION INSTRUCTIONS DIRECT VENT DT-400& DR-400MODELS Millivolt ElectronicTYPICAL INSTALLATION PACKAGINGINTRODUCTION GENERAL INFORMATIONÀCOTE DE LAPPAREIL Millivolt ModelsElectronic Models All ModelsTypical Locations LOCATIONAPPLIANCE AND VENT CLEARANCES Shelf Height inches mmTYPICAL INSTALLATION SEQUENCE DETAILED INSTALLATION STEPSVENT TERMINATION CLEARANCES Vertical Vent Termination ClearancesCanadian Installation US Installation12 inches 30cm 12 inches 30cmframing depth dimension when the finish AND ROUND HORIZONTAL TERMINATION SV4.5HTR12¹⁄₈material drywall thickness is 1/2 in 13mmFIREPLACE SPECIFICATIONS Step 3. INSTALL THE VENT SYSTEMway. Install vent according to local codes listed for operation and installation withSelect Venting System - Horizontal or Vertical Vertical Straight InstallationVERTICAL TERMINATION SYSTEMS ROOF Vertical Offset Installation Vent / Appliance Collar ConnectionC. Attach vent components to each other ConnectionFraming Dimensions for Roof Pitch0/12 6/12TABLE A VERTICAL VENT FIGURES/TABLESH Maximum Figure 23 - Top Vent - STRAIGHTTABLE D VERTICAL VENT FIGURES/TABLESFigure 26 - Rear Vent - THREE ELBOWS Figure 27 - Top Vent - THREE ELBOWSF.Install firestop/spacer at ceiling TYPICAL HORIZONTAL VENT INSTALLATIONHORIZONTAL OUTSIDE WALL TERMINATION SYSTEM A. Plan the vent runConnecting/Recessing Long Square Horizontal attach termination adapterSquare SV4.5HTS Short Square SV4.5HTSS3.Install the round termination SV4.5HTR HORIZONTAL VENT FIGURES/TABLESVenting Components LONG SQUARE TERMINATIONTABLE F V MinimumH Maximum V MinimumHORIZONTAL VENT FIGURES/TABLE CONTINUED TABLE JH + H1 Maximum termination Figure 39- Top Vent - TWO 90 DEGREE ELBOWSC. Route Flex Vent A. Install the Inner Flex PipeB. Install the Outer Flex Pipe B. Electronic Wiring See Figure Step 4. FIELD WIRINGA. SIT and Honeywell Millivolt Wiring Step 6. CONNECTING GAS LINE Optional Gas Flex Line ConnectorFBK-250Blower Kit See Figure Opening Control Compartment DoorStep 7. INSTALLING LOGS AND GLOWING EMBERS Step 9. INSTALLING THE GLASS DOORAdjustment Sit and Honeywell Millivolt Gas ValveStep 10. BURNER ADJUSTMENTS Step 11. HOOD INSTALLATIONBurner Adjustment FINISHING REQUIREMENTS Wall DetailsINSTALLATION ACCESSORIES MANTEL CLEARANCESInches mm COLD CLIMATE INSULATIONModel No. Description INSTALLATION ACCESSORIES ContinuedDescription AND .2 INSTALLATION CODE GAS CONVERSION KITSIn Canada Natural To Propane Gas Conversion Kit SIT SystemsAdjusting Knob Pilot for SIT Millivolt Gas Valve Pilot OrificePilot for Honeywell Millivolt Gas Valve Step 5. Millivolt Appliances Honeywell SystemsSpring Adjusting Screw Pilot PilotAssembly Orifice Ignitor AssemblyAll Models Model No