EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
*See Item D in the Text Below.
Exterior Wall | Center Line |
|
| Inside |
|
| |
| of Termination |
|
|
|
| ||
*18” |
|
|
| Corner Detail |
|
| |
|
|
|
|
|
|
| |
Horizontal |
|
|
|
| G |
|
|
Termination |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
18” | Ventilated Soffit |
|
| V |
|
| |
|
| A |
|
|
| ||
Inside Corner |
|
|
|
|
| ||
|
|
|
| = 9” in U.S. | |||
|
|
|
|
| A | ||
Detail D |
|
|
| = 12” in Canada | |||
|
|
|
|
|
| ||
|
|
|
|
|
|
| 3 ft. |
B |
|
| C | B |
|
| X |
|
|
|
|
| A | ||
L |
| V |
|
|
| A | |
|
| V | Operable |
|
| ||
| Fixed |
|
|
| |||
|
| Closed |
|
| Window |
| 3 ft. |
F | V | Window |
|
|
|
| |
|
|
|
|
|
| ||
|
| C | B |
| J |
| |
V |
|
|
|
| |||
| C | C | B | B |
|
| |
|
|
|
| ||||
| A |
|
|
|
|
|
|
X = Air Supply Inlet |
| V = Vent Terminal | = Area where Terminal is not Permitted |
|
H
D | E |
|
|
M
V
I
V
6
| Canadian Installation* | US Installation** |
|
|
|
A = Clearance above grade, veranda, porch, | 12 inches (30cm)* | 12 inches (30cm)** |
deck, or balcony. |
|
|
|
|
|
B = Clearance to window or door that may be | 6 in (15cm) for appliances | 6 in (15cm) for appliances |
opened. | < 10,000 Btuh (3kW), 12 in (30cm) | < 10,000 Btuh (3kW), 9 in (23cm) |
| for appliances > 10,000 Btuh (3kW) and | for appliances > 10,000 Btuh (3kW) and |
| < 100,000 Btuh (30kW), 36 inches (91cm) | < 50,000 Btuh (15kW), 12 inches (30cm) |
| for appliances > 100,000 Btuh (30kW)* | for appliances > 50,000 Btuh (15kW)** |
C = Clearance to permanently closed window | 12" (305mm) recommended to prevent | 9" (229mm) recommended to prevent |
| window condensation | window condensation |
|
|
|
D = Vertical clearance to ventilated soffit | 18" (458mm) | 18" (458mm) |
located above the terminal within a horizontal |
|
|
distance of 18 inches (458mm) from the center |
|
|
line of the terminal |
|
|
E = Clearance to unventilated soffit | 12" (305mm) | 12" (305mm) |
|
|
|
F = Clearance to outside corner | 5" (12.7cm) minimum | 5" (12.7cm) minimum |
|
|
|
G = Clearance to inside corner | 6" (15.2cm) minimum | 6" (15.2cm) minimum |
H = Clearance to each inside of center line | 3 feet (91cm) within a height of 15 feet | 3 feet (91cm) within a height of 15 feet |
extended above meter/regulator assembly | above the meter/regulator assembly* | above the meter/regulator assembly** |
I = Clearance to service regulator vent outlet | 3 feet (91cm)* | 3 feet (91cm)** |
|
|
|
J = Clearance to nonmechanical air supply inlet | 6 in (15cm) for appliances | 6 in (15cm) for appliances |
to building or the combustion air inlet to any | < 10,000 Btuh (3kW), 12 in (30cm) | < 10,000 Btuh (3kW), 9 in (23cm) |
other appliance | for appliances > 10,000 Btuh (3kW) and | for appliances > 10,000 Btuh (3kW) and |
| < 100,000 Btuh (30kW), 36 inches (91cm) | < 50,000 Btuh (15kW), 12 inches (30cm) |
| for appliances > 100,000 Btuh (30kW)* | for appliances > 50,000 Btuh (15kW)** |
K = Clearance to a mechanical air supply inlet | 6 feet (1.83m)* | 3 feet (91cm) above if within 10 feet (3m) |
|
| horizontally** |
L = Clearance above paved sidewalk or paved | 7 feet (2.13m)‡ | 7 feet (2.13m)‡ |
diveway located on public property |
|
|
M = Clearance under veranda, porch, deck or | 12 inches (30cm)*‡ | 12 inches (30cm)‡ |
balcony |
|
|
*In accordance with the current
**In accordance with the curent ANSI SZ223.1/NFPA 54 National Fuel Gas Codes.
‡A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
*‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:
Figure 8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.