Honeywell VISTA-15PSIA Configurable Zone Type Charts, Zone Conditions Represented Entries

Page 34

Installation and Setup Guide

Configurable Zone Type Charts

 

ENTRY 1

 

 

 

 

ENTRY 2

 

 

 

 

 

Response when system disarmed and zone is:

 

Auto

 

 

 

 

Intact EOL

 

 

Open

 

 

Shorted

 

Restore

 

Vent Zone

 

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0 = no

 

0 = no

 

1

= alarm

 

4

= alarm

 

1

= alarm

 

4 = yes

 

8 = yes

 

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

 

 

 

 

 

see note 5

 

see note 6

 

 

 

 

 

Entry 1 = EOL +

 

Open

 

Entry 2 = Short + auto restore + vent zone

 

ENTRY 3

 

 

 

 

ENTRY 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response when armed STAY and zone is:

 

Byp. when

 

Byp. when

 

 

 

Intact EOL

 

 

Open

 

 

Shorted

 

disarmed

 

armed

 

 

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0 = no

 

0 = no

 

1

= alarm

 

4

= alarm

 

1

= alarm

 

4 = yes

 

8 = yes

 

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

 

 

 

 

 

 

see note 5

 

see note 6

 

 

 

 

 

 

Entry 3 = EOL +

 

Open

 

Entry 4 = Short + byp. disarmed + byp. armed

 

ENTRY 5

 

 

 

 

ENTRY 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response when armed AWAY and zone is:

 

Dial Delay

 

Fault Delay

 

 

 

Intact EOL

 

 

Open

 

 

Shorted

 

(see field *50)

 

(see field *87)

 

 

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0 = no

 

0 = no

 

1

= alarm

 

4

= alarm

 

1

= alarm

 

4 = use delay

 

8 = use delay

 

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

see note 1

 

 

 

 

see note 5

 

see note 6

 

 

 

 

 

 

Entry 5 = EOL +

 

Open

 

Entry 6 = Short + dial delay + fault delay

 

ENTRY 7

 

 

 

ENTRY 8

 

 

 

 

 

 

Display Faults

 

Power Reset/

 

Use Entry

 

Use Exit

 

Respond as

 

 

 

 

Verification

 

Delay 1/2

 

Delay

 

Interior Type

 

 

0 = show alarms

 

0 = no

 

0 = no

 

0 = no

 

0 = no

 

 

when armed

 

4 = power reset

 

1 = delay 1

 

4 = use exit

 

8 = yes

 

 

& disarmed

 

after fault

 

2 = delay 2

 

delay

 

see note 2

 

 

1 = don’t show

 

(with code +

 

 

 

 

 

 

 

alarms when

 

OFF)

 

 

 

 

 

 

 

 

armed (show

 

12 = verification

 

 

 

 

 

 

 

 

alarms, trbles,

 

(see zone

 

 

 

 

 

 

 

 

faults when

 

type 16)

 

 

 

 

 

 

 

 

disarmed)

 

 

 

 

 

 

 

 

 

 

3 = never show

 

 

 

 

 

 

 

 

 

 

any alarms,

 

 

 

 

 

 

 

 

 

 

trbles, faults

 

 

 

 

 

 

 

 

 

 

Entry 7 = fault display + power

 

Entry 8 = entry delay 1/entry delay 2 + exit delay +

 

 

reset/verification

 

 

 

interior zone type

 

 

 

 

 

 

ENTRY 9

 

 

 

 

 

ENTRY 10

 

 

 

 

Alarm Sounds

 

Use Bell

 

Respond as

 

 

Trouble

 

Chime when Chime

 

 

 

 

 

Timeout

 

Fire Zone

 

 

Sounds

 

Mode On

 

 

0

= none

 

0 = no

 

0 = no

 

0

= none

 

0 = no

 

 

1

= steady

 

4 = yes

 

8 = yes

 

1

= periodic

 

4 = yes

 

 

 

keypad

 

 

 

 

 

 

beep

 

 

 

 

2

= steady bell

 

see fields *32,

 

see zone type

 

2

= trouble

 

 

 

 

 

and keypad

 

*33

 

09; see note 4

 

 

beeps

 

 

 

 

3

= pulsing bell

 

 

 

 

 

 

 

 

 

 

 

 

and keypad

 

 

 

 

 

 

 

 

 

 

 

Entry 9 = alarm

 

sounds + bell timeout + fire zone

 

Entry 10 = trouble sounds + chime

 

INTACT

OPEN

SHORTED

EOL

 

 

 

 

ZONE-003-V0

Zone Conditions Represented

in Entries 1-6

Configurable Zone Type Notes

1.Do not use the “fault delay” option with a configurable zone type if it is set for an entry or exit delay, otherwise unpredictable results may occur.

2.To create an interior type zone, select “respond as interior zone type” (entry 8, interior type = yes), and set zone response to “fault” in entries 3-4 to ensure fault displays; do not set as “normal,” “alarm,” or “trouble.”

3.Do not set fire zones to respond as

a“fault” (entries 1-6), otherwise

faults will not display unless the [∗] key is pressed.

4.4219/4229 modules must use EOLRs or unpredictable results may occur.

5.RF Zones: The “open” options in entries 1, 3, and 5 are not applicable for RF zones. Use the “intact EOL” option for normal RF zone conditions and “shorted” for off-normal RF zone conditions.

6.a. Zone-Doubling/Double- Balanced: A short on either zone of a zone-doubled pair or on a double-balanced zone causes a tamper condition.

b.For double-balanced zones, this entry must be “0”.

c.For zone-doubled zones, both zones of the doubled pair must be assigned the same response to a short.

4-10

Image 34
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Features and Installation Highlights Capabilities and FunctionsCompatible Devices Important Installation Highlights Installer Please ReadDevice Mounting and Wiring the Control Installing the Control Cabinet and PC BoardAuxiliary Device Current Draw Worksheet AC Power, Battery, and Ground Connections Wire Run ChartBasic Connections Connecting the Keypads and Other Addressable DevicesSounder Bell Connections Supervised outputLong Range Radio Connections Table of Device AddressesKeypad Notes Size MA or less 100 mA 300 mA 500 mA 600 mAHardwire Zones and Zone Expansion Smoke Detector Notes ZonesRF Receiver No. of Zones Installing the RF Receiver and Wireless Transmitter ZonesCompatible Receivers Receiver ConnectionsTransmitter Battery Life Installing a 5800TMInstalling ModuleInstalling a Keyswitch Keyswitch ConnectionsPowerline Carrier Devices 4204/4229 Relay ModulesOn-Board Triggers With the control as shown belowPhone Module Problems Phone Line 4285/4286 Phone ModuleAudio Alarm Verification Connections AAV, listen-In BankAbout Programming Programming OverviewMechanics of Programming Zone Type Definitions Alarm Alarm by NightHr Silent Alarm Auxiliary AlarmConfigurable No AlarmKeyswitch Response TypeAbout Data Field Programming System Setup Fields ∗20 ∗29Data Field Programming Zone Sounds & Timing ∗31-∗39Dialer Programming ∗40 ∗50 Dynamic Signaling Priority Burglary Dialer DelayDynamic Signaling Delay Zone Programming Menu ModeSystem Status Report Codes Miscellaneous System Fields Event Log Enables Misc. Fault Delay TimeProgram Mode Lockout Options Phone Line Monitor EnablePager Programming Fields Pager 1 Characters 172Pager Delay Option for AlarmsClean Me Option Pager 1 Report OptionsConfigurable Zone Type Options Configurable Zone Type FieldsConfigurable Zone Type Zone Type 90 Report CodesConfigurable Zone Type Charts Zone Conditions Represented EntriesTouch Screen Keypad AUI Enable Keypad Programming FieldsInstallation and Setup Guide Zones and Partitions Menu Mode ProgrammingZone Programming Procedure About Zone Programming ∗56 and ∗58 Menu ModesSummary Screen Hardwire TypeZone Number Zone Type ZTLoop Number Change Input Device typeSerial number Entry and Loop Number Entry Enroll Summary∗58 Expert Programming Mode Procedures Completing Zone ProgrammingTo Delete a Serial Number Zone ProgrammingSerial number ConfirmTemplate Display Wireless Key Programming TemplatesTemplate Number Partition5804BD 2-Way Wireless Key Transmitter Wireless Key Predefined Default TemplatesWireless Key Transmitter Not ConfirmedProgramming Output Devices About Output Device Programming *79/*80 Menu ModeMenu Mode Output Device Mapping Output IdentificationRelay Position Output TypeModule Addresses Output Function No Menu Mode Defining Output FunctionsActivated By = off = Change Device State = Close for 2 seconds Output Action01-08 = zone list ∗ to continue = Stay ClosedAbout Zone Lists *81 Menu Mode Zone List ProgrammingFunction Key About Function Keys *57 Menu ModeProgramming Function Keys Partition NumbeAbout Descriptor Programming *82 Menu Mode Programming Zone Descriptors Menu Mode ∗82Accept Second Word Accept First WordSecond 3-Digit Index No Assigning Partition/Custom Message DescriptorsCharacter Ascii Chart For Adding Custom Words For Entering Zone DescriptorsSchedule Number Programming Installer and User SchedulesStart Time = repeat every third week 4 = repeat every fourth week Repeat OptionRandomize For events 01 Report Code Formats System Communication and OperationPanel Communication with Central Station DigitWhere Code for Type +1/4+1 Report Standard ExpandedSome event codes may not apply to certain control panels Ademco Contact IDCode Definition Attributes Values Keyfob must be enrolled in system first see Wireless KeySystem Security Codes Level User No FunctionsVoice Keypads Keypad CommandsKeypad Functions Function DescriptionSetting the Real-Time Clock Keys Displayed as Zone ∗ /1 ∗ /#Various System Trouble Displays Alpha Display Fixed Disp MeaningInstallation and Setup Guide Checking Transmitter Enrollment Sniffer Mode Testing the SystemAbout Test Procedures System TestDialer Communication Test and Periodic Test Reports Go/No Go Test ModeAutomatic Standby Battery Tests Automatic Periodic Test ReportElectrical Specifications & AccessoriesSecurity Control CommunicationWire Smoke Detector Detector TypeCompatible 5800 Series Transmitters Table Series Transmitter Input Loop IdentificationModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadTo be transmitted Regulatory Agency Statements Industrie CanadaUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations and Warranty Limitations of this Alarm System10-8 Index 10-10 Summary of Connections Limited Warranty K5305-1V5 10/04 Rev. a