Installation and Setup Guide
CABINET | A | B |
|
| CABINET |
|
| BOARD |
| RECEIVER CIRCUIT BOARD | SUPPORTING |
|
| SLOTS |
+ | + |
| CIRCUIT |
| BOARD |
| MOUNTING |
| CLIP |
CONTROL
CIRCUIT
BOARD
| DETAIL A |
MOUNTING | SIDE VIEW |
CLIP | OF BOARD - |
SUPPORTING SLOTS
INSTALLATION WITH RECEIVER CIRCUIT BOARD
WHITE | BLACK | RED |
MOUNTING | MOUNTING | MOUNTING |
CLIP | CLIP | CLIP |
NOTE
A COMBINATION OF THESE MOUNTING CLIPS HAS BEEN INCLUDED IN YOUR INSTALLATION KIT.
USE THE APPROPRIATE CLIPS FOR MOUNTING.
IF NO RF RECEIVER IS USED, MOUNT THE PC BOARD USING EITHER THE WHITE OR BLACK CLIPS, WHICHEVER ARE INCLUDED IN THE CONTROL PANEL'S HARDWARE KIT.
ANTENNA
(2)
SCREW
(2)
GROUNDING LUG
(2)
ANTENNA
MOUNT
(2 PLACES)
DETAIL B
ANTENNA AND GROUNDING
LUG INSTALLATION
Figure 3. Mounting the PC Board and RF Receiver
AUXILIARY DEVICE CURRENT DRAW WORKSHEET
| DEVICE | CURRENT | No. UNITS | TOTAL CURRENT |
6150 | 40mA/70mA** |
|
| |
6160 | Alpha Keypad | 40mA/150mA** |
|
|
6150V | 60mA/160mA** |
|
| |
6160V Alpha Display Voice Keypad | 60mA/190mA** |
|
| |
8132/8142 Series AUI (Symphony) | 150mA/400mA** |
|
| |
6270 | Touch Screen Keypad | 180mA/280mA** |
|
|
5881/5882 RF Receiver | 60mA |
|
| |
5883 | Transceiver | 80mA |
|
|
4219 Zone Expander | 30mA |
|
| |
4204 | Relay Unit | 15/180mA‡ |
|
|
4229 | Zone Expander/Relay Unit | 30/100mA‡ |
|
|
4285 Phone Module | 160mA |
|
| |
4286 Phone Module | 300mA |
|
| |
|
|
|
|
|
* |
|
|
|
|
(Current available from Aux. terminals = 600 | mA max.)† | TOTAL = |
|
*If using hardwire devices such as PIRs, refer to the specifications for that particular unit's current draw. ** Values are for standby/alarm; alarm for keypads means armed with backlighting on and sounder on
†In UL installations, maximum current draw from the Auxiliary Output and the Alarm Output combined must not exceed 600 mA (500 mA max from Aux. Output). ‡Values are for relays OFF/relays ON.
CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE
The California State Fire Marshal and UL have regulations which require that all residential fire alarm control panels must be provided with a backup battery which has sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition. This control panel can meet these requirements without using a supplementary power supply, provided that the panel’s auxiliary power and bell output currents are limited as indicated below.
OUTPUT LIMITATIONS AND CORRESPONDING REQUIRED BATTERIES
OUTPUT CURRENT LIMITATIONS | BATTERY INFORMATION | ||
Output Current Total | Maximum Auxiliary Current | Battery Capacity | Recommended Battery |
|
| To Use (Amp/Hrs) | (Yuasa Model No.) |
600mA maximum total of | 45mA | 4AH | |
auxiliary power plus bell | 160mA | 7AH | |
output currents | 200mA | 8AH | |
| 425mA | 14AH | |
| 500mA | 17.2AH |
‡ NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit