Honeywell VISTA-15P, VISTA-20P Accept First Word, Second 3-Digit Index No, Accept Second Word

Page 51

Menu Mode Programming

ZN 01 BAC K

Accept First Word

6 = save word and go to next word in this descriptor; 8 = save word and go to next zone Press [6] to accept the selected word and continue to the next word, or press [8] if this is the only word you are using for the descriptor.

ZN 01 BAC K

DOO R

Second 3-Digit Index No.

see index for entries; [] to continue

Enter the 3-digit number for the next word. In our example, the word is DOOR, whose number is “057.” Enter # 0 5 7.

ZN 01 BAC K DO OR

Accept Second Word

6 = save word and go to last word in this descriptor; 8 = save word and go to next zone

Press [6] to accept the selected word and continue to the next word, or press [8] if these are the only words you are using for the descriptor.

When descriptor is finished, press [8] to save all words in memory.

ZN 01 B ACK DO OR

Summary Screen

[] to continue

The flashing cursor will disappear, indicating that the word(s) are stored in memory for that zone, as shown in the summary display at the left.

To enter a descriptor for the next zone, press [] plus the desired zone number. The summary display appears. Repeat the previous steps to enter the descriptor for the zone.

Adding Custom Words (will not be annunciated by 4285/4286 Phone Module)

You can add up to 10 installer-defined words to the built-in vocabulary, which can then be used when programming zone descriptors. Each of the 10 words can actually consist of a word string of one or more words, but no more than ten characters can be used for each word or word string.

When adding custom words, the keypad keys perform the following functions:

[4]Moves cursor one space to the left.

[6]Moves cursor one space to the right.

[8]Saves the new word in the system's memory.

1.Select Custom Word mode (enter 1) when the prompt “CUSTOM WORD ?” is displayed.

2.Enter the number (01–10†) of the custom word or word string to be created, corresponding to index numbers 245 - 254 respectively (for example, if you are creating the first custom word or word-string, enter 01, for the second, enter 02, etc.). A cursor will now appear at the beginning of the second line.

or 11, 12, 13 for partition 1, partition 2 and common lobby descriptors respectively. See Assigning Partition Descriptors paragraph below.

NOTE: Custom words 8, 9, and 10 are “reminder words” that are programmed using Scheduling Mode.

3.Refer to the Character List of letters, numbers, and symbols on a following page.

Press [#], followed by the two-digit entry for the first letter you would like to display (e.g., # 65 for “A”). The cursor will then move to the right, in position for the next character.

To delete a character, simply enter the SPACE character (#32).

4.Repeat Step 3 to create the desired word(s). Note that the “4” key can be used to move the cursor to the left, if necessary. Remember, no word or word-string can exceed 10 characters.

5.Press the [8] key to save the custom word(s) and return to the “CUSTOM WORD ?” display.

Repeat Steps 2–5 for other custom words to be entered. To change a custom word, just overwrite it. If no more are to be entered now, press [0] to return to the Descriptor entry. The custom word(s) will be automatically added to the built-in vocabulary.

Assigning Partition/Custom Message Descriptors

VISTA-15P: You can create a custom message display that appears on alpha keypads instead of “System Ready.” To assign a custom message, use word number 11 as described below.

VISTA-20P: You can assign a partition descriptor (up to 16 characters) for each partition plus the common lobby. The system displays the appropriate partition’s word instead of “DISARMED READY TO ARM.” Use the same procedure as for adding custom words (described above), but use these word numbers in step 2:

11 = partition 1 ___________________________________________

12= partition 2 ___________________________________________ (VISTA-20P only)

13= common lobby ________________________________________ (VISTA-20P only)

Once a custom word is entered in any of these word locations (11-13),

5-15

Image 51
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Capabilities and Functions Features and Installation HighlightsImportant Installation Highlights Installer Please Read Compatible DevicesDevice Installing the Control Cabinet and PC Board Mounting and Wiring the ControlAuxiliary Device Current Draw Worksheet Wire Run Chart AC Power, Battery, and Ground ConnectionsSupervised output Connecting the Keypads and Other Addressable DevicesSounder Bell Connections Basic ConnectionsSize MA or less 100 mA 300 mA 500 mA 600 mA Table of Device AddressesKeypad Notes Long Range Radio ConnectionsHardwire Zones and Zone Expansion Zones Smoke Detector NotesReceiver Connections Installing the RF Receiver and Wireless Transmitter ZonesCompatible Receivers RF Receiver No. of ZonesModule Installing a 5800TMInstalling Transmitter Battery LifeKeyswitch Connections Installing a Keyswitch4204/4229 Relay Modules Powerline Carrier DevicesWith the control as shown below On-Board TriggersPhone Line 4285/4286 Phone Module Phone Module ProblemsBank Audio Alarm Verification Connections AAV, listen-InProgramming Overview About ProgrammingMechanics of Programming Zone Type Definitions Auxiliary Alarm Alarm by NightHr Silent Alarm AlarmResponse Type No AlarmKeyswitch ConfigurableZone Sounds & Timing ∗31-∗39 System Setup Fields ∗20 ∗29Data Field Programming About Data Field ProgrammingDialer Programming ∗40 ∗50 Zone Programming Menu Mode Burglary Dialer DelayDynamic Signaling Delay Dynamic Signaling PrioritySystem Status Report Codes Miscellaneous System Fields Phone Line Monitor Enable Misc. Fault Delay TimeProgram Mode Lockout Options Event Log EnablesPager Programming Fields Pager 1 Report Options 172Pager Delay Option for AlarmsClean Me Option Pager 1 CharactersZone Type 90 Report Codes Configurable Zone Type FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Touch Screen Keypad AUI EnableInstallation and Setup Guide About Zone Programming ∗56 and ∗58 Menu Modes Menu Mode ProgrammingZone Programming Procedure Zones and PartitionsZone Type ZT Hardwire TypeZone Number Summary ScreenEnroll Summary Input Device typeSerial number Entry and Loop Number Entry Loop Number ChangeCompleting Zone Programming ∗58 Expert Programming Mode ProceduresConfirm Zone ProgrammingSerial number To Delete a Serial NumberPartition Wireless Key Programming TemplatesTemplate Number Template DisplayNot Confirmed Wireless Key Predefined Default TemplatesWireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterOutput Identification About Output Device Programming *79/*80 Menu ModeMenu Mode Output Device Mapping Programming Output DevicesOutput Type Relay PositionModule Addresses Menu Mode Defining Output Functions Output Function NoActivated By = Stay Closed Output Action01-08 = zone list ∗ to continue = off = Change Device State = Close for 2 secondsZone List Programming About Zone Lists *81 Menu ModePartition Numbe About Function Keys *57 Menu ModeProgramming Function Keys Function KeyProgramming Zone Descriptors Menu Mode ∗82 About Descriptor Programming *82 Menu ModeAssigning Partition/Custom Message Descriptors Accept First WordSecond 3-Digit Index No Accept Second WordFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsProgramming Installer and User Schedules Schedule NumberStart Time Repeat Option = repeat every third week 4 = repeat every fourth weekRandomize For events 01 Digit System Communication and OperationPanel Communication with Central Station Report Code FormatsCode for Type +1/4+1 Report Standard Expanded WhereAdemco Contact ID Some event codes may not apply to certain control panelsCode Definition Level User No Functions Keyfob must be enrolled in system first see Wireless KeySystem Security Codes Attributes ValuesFunction Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone ∗ /1 ∗ /# Setting the Real-Time ClockAlpha Display Fixed Disp Meaning Various System Trouble DisplaysInstallation and Setup Guide System Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsCommunication Specifications & AccessoriesSecurity Control ElectricalDetector Type Wire Smoke DetectorSeries Transmitter Input Loop Identification Compatible 5800 Series Transmitters TableModel Product Input Type Description 5827 Wireless Keypad Can be used to turn the burglary protection on and offTo be transmitted Industrie Canada Regulatory Agency StatementsUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations of this Alarm System Limitations and Warranty10-8 Index 10-10 Summary of Connections K5305-1V5 10/04 Rev. a Limited Warranty