SECURING THE PREMISES

Arming the System

Arming in Stay Mode

Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed.

To arm in STAY mode:

+ Your User code**

STAY

or press and hold

STAY

**

** See Quick Arming paragraph.

The keypad beeps three times and displays the armed STAY message. The red ARMED indicator lights and the system announces “armed STAY–exit now.”

When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur.

Restarting Exit Delay While System Armed

Ask your installer if this feature is active for your system. If active, you can restart the exit delay at any time after arming in STAY mode. This is useful if you wish to open the entry/exit door to let someone in after arming the system, and avoids having to disarm the system and then re-arm it again.

To restart exit delay while system is armed in STAY mode: Press

STAY

key

Arming In Away Mode

Use this mode when no one will be staying on the premises. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed.

To arm in AWAY mode:

+ Your User code **

AWAY

or press and hold

AWAY

**

** See Quick Arming paragraph.

The keypad beeps twice, or beeps continuously if exit warning has been programmed for your system, and displays the armed AWAY message. The red ARMED indicator lights and the system announces “armed AWAY–exit now.”

When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also re-enter through the entrance door, but you must disarm the system within the entry delay period or an alarm will occur.

– 16 –

Image 16
Contents Ademco LYNXR-I Page Table of Contents Page System Overview AUX Alarms ZonesFire Protection Burglary ProtectionTwo-Way Voice Feature General OperationTo arm in Stay mode To restart exit delayTo arm in Away mode To arm with no DelayTo turn Test mode on To turn Test mode offTo remotely activate X10 devices To remotely activate X10 devices 7About the Master Keypad GeneralMaster Keypad Definitions Armed ReadySystem Overview About the Display and Indicators LED MeaningsChecking System Status General InformationPress the Status Key System Can Be ArmedArming in Stay Mode Arming In Away ModeRestarting Exit Delay While System Armed Arming the SystemTo arm with no Delay if Quick Arm is active Arming the System With No DelayQuick Arming Entry/Exit Delays Exit DelayEntry Delay Exit Alarms Exit Alarm ActiveTo disarm the system and silence burglary alarms Memory of AlarmDisarming the System Bypassing Protection Zones Bypassing Individual ZonesForced Bypass Displaying Bypassed ZonesChime Mode Panic Keys / Chime ModePanic Keys Paging Feature Automatic PagingCode Format Manual PagingFollow Me Announcement Feature Follow Me Reminder and System AnnouncementsSystem Announcements Reminder AnnouncementsTo program Follow Me reminder telephone number To delete Follow Me reminder telephone numberTo deactivate X10 devices 7 Device DescriptionsDevice Description Message Recording/Playback/Volume Control Recording a MessageMessage Playback Deleting MessagesTo adjust message playback/system announcement volume Adjusting the VolumeTo restore announcement sounding Defining the AUX Function AUX FunctionPerforming the AUX function Clock/Calendar HourMinute MonthDay YearScheduling User Interface = the value that was last stored in the memory Schedule numberXx bd Event Identifier Entries Entry Event CommentDay of Week Entries Entry DayUsing Remote Phone Control Feature Remote Phone Control FeatureEnter Remote Phone Control Commands To remotely disarm system To remotely arm in Away modeTo remotely deactivate X10 devices 1-6 # + 7 + device no To remotely Bypass zonesSpeaker Phone Feature Using the Speaker Phone FeatureUser Functions General Information Silencing a Fire AlarmCase of Fire Fire Alarm System Emergency Evacuation Security Codes To Add/Delete a User or Change a Users CodeChanging the Master User Code Add a user codeEntering Test Mode Testing the System to be conducted weeklyExit Test Mode Typical Trouble Condition Displays Trouble MessagesRoutine Care Changing the LYNXR-I System Battery Low Battery Conditions in Wireless SensorsMaintaining your system Summary Of Audible Notification LED Meanings Federal Communications Commission FCC Part 15 Statement UL Notice This is a Grade a residential systemIndustry Canada Federal Communications Commission FCC Part Ringer Equivalence Number NoticeEvent of Telephone Operational Problems Servicing Information Owners Insurance Premium Credit Request Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Index Manual Paging Limitations of this Alarm System ONE Year Limited Warranty Page Page Page Page Page ‡K14115$Š