Summary Of Audible Notification
*UPPER CASE indicates announcements after pressing STATUS once. Lower case indicates announcements after pressing STATUS twice.
SOUND | CAUSE | DISPLAY | ANNOUNCEMENT* |
INTERRUPTED | FIRE ALARM | FIRE ALARM is displayed; zone | fire alarm + zone voice |
Speaker and |
| number in alarm displayed. | descriptor |
external piezo and |
|
| (Voice descriptor is |
bell |
|
| interlaced with the siren and |
|
|
| sounds every 45 seconds) |
CONTINUOUS | BURGLARY/AUDIBLE | ALARM is displayed; zone number | alarm + zone voice |
Speaker and | EMERGENCY ALARM | in alarm displayed. | descriptor |
external piezo and |
|
| (Voice descriptor is |
bell |
|
| interlaced with the siren and |
|
|
| sounds every 45 seconds) |
ONE SHORT BEEP | a. SYSTEM DISARM | a. Green LED on steady | a. |
(not repeated) | b. SYSTEM ARMING | b. The number of the open protection | ARM |
Speaker and | ATTEMPT WITH AN | zone is displayed after pressing | b. |
external piezo | OPEN ZONE. | STATUS. | TO ARM |
| c. BYPASS VERIFY | c. Numbers of the bypassed | c. zones bypassed |
|
| protection zones are displayed |
|
|
| (One beep is heard for each zone |
|
|
| displayed). |
|
ONE SHORT BEEP | a. SYSTEM IS IN TEST | a. Opened zone identifications will | a. No announcement |
(once every 45 | MODE | appear. |
|
secs) Speaker and | b. LOW BATTERY AT A | b. LOW BAT displayed with zone | b. low battery + zone voice |
external piezo | TRANSMITTER | number of transmitter. | descriptor |
| c. SYSTEM LOW | c. LOW BAT displayed with no zone | c. system low battery |
| BATTERY | no. |
|
| d. FAIL TO | d. FC displayed with no zone no. | d. check system |
| COMMUNICATE |
|
|
TWO SHORT | ARM AWAY OR MAXIMUM | AWAY or AWAY + INSTANT is | ARMED AWAY [INSTANT] – |
BEEPS |
| displayed. Red ARMED indicator is | EXIT NOW |
Speaker and ext. |
| lit. |
|
piezo |
|
|
|
THREE SHORT | a. ARM STAY OR INSTANT | a. STAY or STAY + INSTANT is | a. ARMED STAY [INSTANT] |
BEEPS |
| displayed. Red ARMED indicator is | – EXIT NOW |
Speaker and | b. ZONE OPENED WHILE | lit. |
|
external piezo | SYSTEM IS IN CHIME | b. CHIME displayed, number of open | b. zone voice descriptor |
| MODE. | protection zone will be displayed if |
|
|
| the Status key is pressed. |
|
RAPID BEEPING | a. TROUBLE | a. FAULT displayed. Number of | a. fault + zone voice |
Speaker and |
| troubled protection zone is | descriptor |
external piezo | b. MEMORY OF ALARM | displayed. |
|
|
| b. FIRE ALARM or ALARM is | b. fire alarm or alarm + zone |
|
| displayed; zone number in alarm is | voice descriptor |
|
| displayed. |
|
SLOW BEEPING | a. ENTRY DELAY | a. Exceeding the delay time without | a. DISARM SYSTEM NOW |
Speaker and | WARNING | disarming causes alarm. |
|
external piezo |
| b. AWAY or AWAY + INSTANT is | b. ARMED [AWAY] |
| b. EXIT DELAY WARNING | displayed | [INSTANT] – EXIT NOW |
|
|
|
|
– 47 –