LYNXR-I is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N

LYNXRCHKIT-HC) is installed.

Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association:

1.Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants.

2.Determine two means of escape from each room. One path of escape should lead to the door that permits normal exit from the building. The other should be an alternative escape, such as a window, should your path to that door be unpassable. Station an escape ladder at such windows if there is a long drop to the ground.

3.Sketch a floor plan of the building. Show windows, doors, stairs and rooftops that can be used to escape. Indicate escape routes for each room. Keep these routes free from obstruction and post copies of the escape routes in every room.

4.Assure that all bedroom doors are shut while you are asleep. This will prevent deadly smoke from entering while you escape.

5.Try the door. If the door is hot, check your alternate escape route. If the door is cool, open it cautiously. Be prepared to slam the door if smoke or heat rushes in.

6.When smoke is present, crawl on the ground. Do not walk upright, since smoke rises and may overcome you. Clearer air is near the floor.

7.Escape quickly; don't panic.

8.Establish a place outdoors, away from your house, where everyone can meet and then take steps to contact the authorities and account for those missing. Choose someone to assure that nobody returns to the house — many die going back.

 

CLOSET

BEDROOM

 

PORCH

BEDROOM

BATH

BEDROOM

 

2nd FLOOR

KITCHEN

BEDROOM

BACK DOOR

BEDROOM

BATH

1st FLOOR

BACK

FRONT

01000-023-V0

– 42 –

Image 42
Contents Ademco LYNXR-I Page Table of Contents Page System Overview AUX Fire Protection AlarmsZones Burglary ProtectionTwo-Way Voice Feature General OperationTo arm in Away mode To arm in Stay modeTo restart exit delay To arm with no DelayTo remotely activate X10 devices To turn Test mode onTo turn Test mode off To remotely activate X10 devices 7About the Master Keypad GeneralMaster Keypad Definitions Armed ReadySystem Overview About the Display and Indicators LED MeaningsPress the Status Key Checking System StatusGeneral Information System Can Be ArmedRestarting Exit Delay While System Armed Arming in Stay ModeArming In Away Mode Arming the SystemArming the System With No Delay To arm with no Delay if Quick Arm is activeQuick Arming Entry Delay Entry/Exit DelaysExit Delay Exit Alarms Exit Alarm ActiveMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Forced Bypass Bypassing Protection ZonesBypassing Individual Zones Displaying Bypassed ZonesPanic Keys / Chime Mode Chime ModePanic Keys Code Format Paging FeatureAutomatic Paging Manual PagingSystem Announcements Follow Me Announcement FeatureFollow Me Reminder and System Announcements Reminder AnnouncementsTo program Follow Me reminder telephone number To delete Follow Me reminder telephone numberDevice Descriptions To deactivate X10 devices 7Device Description Message Playback Message Recording/Playback/Volume ControlRecording a Message Deleting MessagesAdjusting the Volume To adjust message playback/system announcement volumeTo restore announcement sounding AUX Function Defining the AUX FunctionPerforming the AUX function Minute Clock/CalendarHour MonthDay YearScheduling User Interface = the value that was last stored in the memory Schedule numberXx bd Event Identifier Entries Entry Event CommentDay of Week Entries Entry DayRemote Phone Control Feature Using Remote Phone Control FeatureEnter To remotely deactivate X10 devices 1-6 # + 7 + device no Remote Phone Control Commands To remotely disarm systemTo remotely arm in Away mode To remotely Bypass zonesSpeaker Phone Feature Using the Speaker Phone FeatureUser Functions Silencing a Fire Alarm General InformationCase of Fire Fire Alarm System Emergency Evacuation Changing the Master User Code Security CodesTo Add/Delete a User or Change a Users Code Add a user codeTesting the System to be conducted weekly Entering Test ModeExit Test Mode Trouble Messages Typical Trouble Condition DisplaysRoutine Care Low Battery Conditions in Wireless Sensors Changing the LYNXR-I System BatteryMaintaining your system Summary Of Audible Notification LED Meanings UL Notice This is a Grade a residential system Federal Communications Commission FCC Part 15 StatementIndustry Canada Federal Communications Commission FCC Part Ringer Equivalence Number NoticeEvent of Telephone Operational Problems Servicing Information Owners Insurance Premium Credit Request Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Index Manual Paging Limitations of this Alarm System ONE Year Limited Warranty Page Page Page Page Page ‡K14115$Š