Honeywell LYNXR-I manual Message Recording/Playback/Volume Control, Recording a Message

Page 26

USER FUNCTIONS

Message Recording/Playback/Volume Control

The LYNXR-I Message Center allows you to record, play and delete messages. The maximum message duration is 85 seconds.

NOTES: (1) The Record/playback functions can only be performed from the master keypad. It cannot be performed from any other wireless keypad (ex. 5827).

(2)If the system loses electrical power, all messages will be erased.

(3)Message Play/Record will not be available if a report must be sent.

(4)Individual messages cannot be played back or deleted.

Recording a Message

To record a message: FUNCTION

+

RECORD

The keypad displays “REC MESSAGE.” Begin speaking into the microphone.

The recording will automatically stop after 85 seconds, if a message has been recorded. The keypad will beep twice and “REC” will no longer be displayed. “MESSAGE” will still be displayed.

To stop recording before the end of 85 seconds: Press

OFF

The keypad beeps twice, the REC display turns off, but the MESSAGE display remains on.

Additional messages can be recorded, as long as there is recording time remaining, by repeating the above steps.

NOTE: If you are trying to record a new message and the message center is already full, the system will announce “END MESSAGE” and “REC MESSAGE” will not be displayed. If the message center is full all old messages must be deleted before new messages can be recorded. See Deleting Messages section.

Message Playback

The lighted word MESSAGE indicates that a new message is in memory. After playing the message, the MESSAGE display turns off. See NOTE below if using a wireless keypad.

To play back a message:

FUNCTION

+

PLAY

All recorded messages will be announced sequentially. A short beep will sound between messages.

To skip a message: Press []

Deleting Messages

To delete all messages: FUNCTION + DELETE

While the messages are being announced: Press FUNCTION

+

DELETE

A double beep will sound confirming that the messages have been deleted.

– 26 –

Image 26
Contents Ademco LYNXR-I Page Table of Contents Page System Overview AUX Fire Protection AlarmsZones Burglary ProtectionTwo-Way Voice Feature General OperationTo arm in Away mode To arm in Stay modeTo restart exit delay To arm with no DelayTo remotely activate X10 devices To turn Test mode onTo turn Test mode off To remotely activate X10 devices 7About the Master Keypad GeneralMaster Keypad Definitions Armed ReadySystem Overview About the Display and Indicators LED MeaningsPress the Status Key Checking System StatusGeneral Information System Can Be ArmedRestarting Exit Delay While System Armed Arming in Stay ModeArming In Away Mode Arming the SystemQuick Arming Arming the System With No DelayTo arm with no Delay if Quick Arm is active Entry Delay Entry/Exit DelaysExit Delay Exit Alarms Exit Alarm ActiveDisarming the System Memory of AlarmTo disarm the system and silence burglary alarms Forced Bypass Bypassing Protection ZonesBypassing Individual Zones Displaying Bypassed ZonesPanic Keys Panic Keys / Chime ModeChime Mode Code Format Paging FeatureAutomatic Paging Manual PagingSystem Announcements Follow Me Announcement FeatureFollow Me Reminder and System Announcements Reminder AnnouncementsTo program Follow Me reminder telephone number To delete Follow Me reminder telephone numberDevice Description Device DescriptionsTo deactivate X10 devices 7 Message Playback Message Recording/Playback/Volume ControlRecording a Message Deleting MessagesTo restore announcement sounding Adjusting the VolumeTo adjust message playback/system announcement volume Performing the AUX function AUX FunctionDefining the AUX Function Minute Clock/CalendarHour MonthDay YearScheduling User Interface = the value that was last stored in the memory Schedule numberXx bd Event Identifier Entries Entry Event CommentDay of Week Entries Entry DayEnter Remote Phone Control FeatureUsing Remote Phone Control Feature To remotely deactivate X10 devices 1-6 # + 7 + device no Remote Phone Control Commands To remotely disarm systemTo remotely arm in Away mode To remotely Bypass zonesSpeaker Phone Feature Using the Speaker Phone FeatureUser Functions Case of Fire Silencing a Fire AlarmGeneral Information Fire Alarm System Emergency Evacuation Changing the Master User Code Security CodesTo Add/Delete a User or Change a Users Code Add a user codeExit Test Mode Testing the System to be conducted weeklyEntering Test Mode Routine Care Trouble MessagesTypical Trouble Condition Displays Maintaining your system Low Battery Conditions in Wireless SensorsChanging the LYNXR-I System Battery Summary Of Audible Notification LED Meanings Industry Canada UL Notice This is a Grade a residential systemFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part Ringer Equivalence Number NoticeEvent of Telephone Operational Problems Servicing Information Owners Insurance Premium Credit Request Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Index Manual Paging Limitations of this Alarm System ONE Year Limited Warranty Page Page Page Page Page ‡K14115$Š