Honeywell LYNXR-I manual Using Remote Phone Control Feature, Enter

Page 36
NOTE
(1) All voice announcements on the phone line will also be announced on the local speaker, unless the system has been placed in the mute mode.
(2) Entry/Exit beeps will be terminated if you enter the remote phone access mode.

USER FUNCTIONS

Remote Phone Control Feature

The LYNXR-Series is equipped with a remote interactive phone capability that permits access to the security system from any off-site touch-tone telephone using all user codes. If this feature has been programmed, the system will provide the appropriate voice messages and any system beeping sounds indicating the status of the security system over the phone line. (Refer to Summary of Audible Notification for further information.) The following functions can be performed from any remote touch- tone telephone:

• Disarm the system.

• Arm the system in STAY or AWAY mode.

• Activate or deactivate X10 devices.

• Bypass zones.

• Check system status.

The remote access session will be aborted if:

A report must be sent.

Any local or wireless key entry (e.g. 5827), except [*], is made.

User Code is not entered within eight (8) seconds of call pickup (during the “system…..system announcement).

No keys are depressed for a period of 15 seconds and while no announcement has been made by the system. Any remote key entry will, however extend this timeout back to 15 seconds.

It will not be possible to begin a remote access session if:

A report must be sent

The system is in any Test mode.

During real time clock setting.

During scheduling setup.

Panel is in shutdown mode (programmed by your installer).

Panel is in Macro learning mode.

Remote phone control feature has not been enabled by your installer.

NOTE: If a remote phone session is not granted by the system, for any of the reasons identified above, a modem tone will be generated before the end of the session.

Using Remote Phone Control Feature

Dial the controls’s phone number. If no answering machine is present, the control will pick up between 1 and 14 rings, depending on the number programmed by your installer and will periodically announce “SYSTEM ENTER CODE”. During a remote phone control session “PC” will be displayed on the control.

Enter:

Your user code

(within eight seconds)

The system status will be announced. Enter phone control commands as described on the next page:

If an answering machine is on the premises, you need to dial the premises and hang up on the first ring. Wait at least five (5) seconds (but no more than 22 seconds) and dial the premises phone number again. The control will pick up and periodically announce “SYSTEM”.

– 36 –

Image 36
Contents Ademco LYNXR-I Page Table of Contents Page System Overview AUX Alarms ZonesFire Protection Burglary ProtectionTwo-Way Voice Feature General OperationTo arm in Stay mode To restart exit delayTo arm in Away mode To arm with no DelayTo turn Test mode on To turn Test mode offTo remotely activate X10 devices To remotely activate X10 devices 7About the Master Keypad GeneralMaster Keypad Definitions Armed ReadySystem Overview About the Display and Indicators LED MeaningsChecking System Status General InformationPress the Status Key System Can Be ArmedArming in Stay Mode Arming In Away ModeRestarting Exit Delay While System Armed Arming the SystemArming the System With No Delay To arm with no Delay if Quick Arm is activeQuick Arming Entry/Exit Delays Exit DelayEntry Delay Exit Alarms Exit Alarm ActiveMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Bypassing Protection Zones Bypassing Individual ZonesForced Bypass Displaying Bypassed ZonesPanic Keys / Chime Mode Chime ModePanic Keys Paging Feature Automatic PagingCode Format Manual PagingFollow Me Announcement Feature Follow Me Reminder and System AnnouncementsSystem Announcements Reminder AnnouncementsTo program Follow Me reminder telephone number To delete Follow Me reminder telephone numberDevice Descriptions To deactivate X10 devices 7Device Description Message Recording/Playback/Volume Control Recording a MessageMessage Playback Deleting MessagesAdjusting the Volume To adjust message playback/system announcement volumeTo restore announcement sounding AUX Function Defining the AUX FunctionPerforming the AUX function Clock/Calendar HourMinute MonthDay YearScheduling User Interface = the value that was last stored in the memory Schedule numberXx bd Event Identifier Entries Entry Event CommentDay of Week Entries Entry DayRemote Phone Control Feature Using Remote Phone Control FeatureEnter Remote Phone Control Commands To remotely disarm system To remotely arm in Away modeTo remotely deactivate X10 devices 1-6 # + 7 + device no To remotely Bypass zonesSpeaker Phone Feature Using the Speaker Phone FeatureUser Functions Silencing a Fire Alarm General InformationCase of Fire Fire Alarm System Emergency Evacuation Security Codes To Add/Delete a User or Change a Users CodeChanging the Master User Code Add a user codeTesting the System to be conducted weekly Entering Test ModeExit Test Mode Trouble Messages Typical Trouble Condition DisplaysRoutine Care Low Battery Conditions in Wireless Sensors Changing the LYNXR-I System BatteryMaintaining your system Summary Of Audible Notification LED Meanings UL Notice This is a Grade a residential system Federal Communications Commission FCC Part 15 StatementIndustry Canada Federal Communications Commission FCC Part Ringer Equivalence Number NoticeEvent of Telephone Operational Problems Servicing Information Owners Insurance Premium Credit Request Notifies Insert B = Burglary, F = FireOwners Insurance Premium Credit Request Index Manual Paging Limitations of this Alarm System ONE Year Limited Warranty Page Page Page Page Page ‡K14115$Š