Bosch Appliances 9 6 BLCC110U manual Set Part 2 Zones, Smoke Sensor Reset, Zone Name

Page 17

Inputs > Commands >

Set Part 2 Zones

MENU 3-0-4

This menu allows you to program which zones are to be monitored when an area has been turned Part 2 On.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [4].

A list of areas will display on the keypad.

2.Use the [] and [] keys to select the area that you want to program zones for Part 2 On, then press [OK]. Alternatively, you can enter the area number that you want to program Part 2 On zones, then press [OK].

The keypad will list all zones that can be programmed for Part 2 On. A ‘’ displayed on the right side of the zone name indicates that the zone is already bypassed.

Z001 Zone 1 Name

Z002 Zone 2 Name

Z003 Zone 3 Name

Press  OK or MENU

3.Use the [] and [] keys to select the zone that you want to set for Part 2, then press [OK]. Alternatively, you can enter the zone number that you want to set for Part 2, then press [OK].

If the zone is not programmed for Part 2, the keypad will prompt:

Zone 1 Z001

Is not a PART2 Zone,

To Enable, Press ON.

To Go Back Press OK

If the zone is programmed for Part 2, the keypad will prompt:

Zone 1 Z001

Is a PART2 Zone,

To remove, Press OFF.

To Go Back Press OK

4.Press [ON] to monitor the zone when the area is turned Part 2 On, or press [OFF] so that you do not monitor the zone when the area is turned Part 2 On.

5.Press [OK] to save and exit, or press [MENU] to exit without saving.

 

Solution 64 User Guide

Inputs > Commands >

 

 

Smoke Sensor Reset

 

MENU 3-0-5

This menu allows you to reset smoke sensors.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [0] + [5].

A list of different areas will display on the keypad.

2.Use the [] and [] keys to select the area that you want to reset the smoke detectors, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will display the following:

Smoke detector reset in

Progress. Please wait

3.The keypad will automatically return to the menu when all smoke detectors in the area has been reset.

Inputs > Zone Properties >

Zone Name

MENU 3-1-0

This menu allows you to program up to 16 characters for the name of each zone.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [3] + [1] + [0].

A list of different zones will display on the keypad.

2.Use the [] and [] keys to select the zone name that you want to change, then press [OK] to select. Alternatively, you can enter the zone number, then press [OK].

The keypad will display the following:

Zone Name Z001

Zone 1 Name

Press ◄► OK to SAVE

3.Use the [] and [] keys to scroll the cursor left and right across the zone name text. Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Bosch Security Systems

 

09/06

 

BLCC110U

17

 

 

Image 17
Contents Solution Telepermit Note Copyright Notice TrademarksContents Program Menu Tree Access Areas Inputs OutputsExample Comms Devices SystemUser’s Guide FeaturesNtroduc tion About the Keypad Reporting AlarmsFor 2 sec Keypad KeysDon’t exit before the delay time expires and an AlarmExit delay door is faulted, an alarm occurs To indicate you have exited Menu modeTurning An Area All On Silencing AlarmsBasic System Operation Change Own PIN System ProgrammingEnter New PIN for Press OK or MenuDelete PIN Change Other PINAdd PIN Delete Token Add TokenToken Status Add KeyfobArea Assignment Delete KeyfobUser Name Access Assignment Timer GroupArea Status A001 Main OfficeTurn Area On/Off Area 1 NameTurn All Areas On Turn All Areas OffArea Name Chime On/OffZone Status A001 Reception Area Set Chime Zones Bypass ZonesZ001 Zone 1 Name  Z002 Zone 2 Name Z003 Zone 3 Name Press  OK or MenuSmoke detector reset Progress. Please wait Smoke Sensor ResetSet Part 2 Zones Zone NameOutput Status Walk Test All ZonesWalk Test a Single Zone Output Name Turn Output On/OffOutput 1 Name O001 Is Off and Ready Press OK or Menu Output 1 Name O001 Is on and Ready Press OK or MenuInternal Siren Test External Siren TestStrobe Test A002 Area 2 NameCall Forward On/Off Call/Answer RASCheck Web Email Email System LogCustomer Call Forward On NumberCall Forward Off Number Send Test Report VolumeLAN Status ContrastPanel Status Keypad 001 Backlight Press OK to SaveSystem Trouble Z001 Zone 1 NameTrouble Condition Description Set Date & Time History LogName TimeKeypad Hi/Lo Temp DayStart / Stop Day Battery test in progress Please wait Battery TestIf the battery has passed the test, the keypad will display Battery test Passed Press OK to continueInstallation Details Areas NdexSmoke Detectors