Bosch Appliances 9 6 BLCC110U manual Turn Output On/Off, Output Name

Page 19

Output 1 Name O001

Is Off and Ready

Press OK or MENU

The keypad will display the following when the output is off and missing:

Output 1 Name O001

Is Off and Ready

Connection Trouble

Press OK or MENU

The keypad will display the following when the output is ON and OK:

Output 1 Name O001

Is ON and Ready

Press OK or MENU

The keypad will display the following when the output is ON and missing:

Output 1 Name O001

Is ON and Ready

Connection Trouble

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Outputs > Commands >

Turn Output On/Off

MENU 4-0-1

This menu allows you to turn outputs that have been programmed by your security company on or off. These outputs can be programmed to control outside lighting, pool pumps, watering systems etc.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [4] + [0] + [1].

If a valid PIN is required, the keypad will prompt you to enter your PIN.

2.Use the [] and [] keys to select the output name that you want to change, then press [OK] to select. Alternatively, you can enter the output number, then press [OK].

3.To toggle the output on or off, use the [ON] and [OFF] keys.

The keypad will display the following when the output is off:

Solution 64 User Guide

Output 1 Name O001

Output is OFF,

To Turn ON,Press ON.

To Go Back Press OK

To turn the output on, press [ON].

The keypad will display the following when the output is on:

Output 1 O001

Output is ON,

To Turn OFF,Press OFF.

To Go Back Press OK

To turn the output off, press [OFF].

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Outputs > Properties >

Output Name

MENU 4-1-0

This menu allows you to program the name for each output. Each output name supports up to 16 characters.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [4] + [1] + [0].

A list of different outputs will display on the keypad.

2.Use the [] and [] keys to select the output name that you want to change, then press [OK] to select. Alternatively, you can enter the output number, then press [OK].

The keypad will display the following:

Output Name O001

Output 1

Press ◄► OK to SAVE

3.Use the [] and [] keys to scroll the cursor left and right across the output name text. Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

Bosch Security Systems

 

09/06

 

BLCC110U

19

 

 

Image 19
Contents Solution Telepermit Note Copyright Notice TrademarksContents Comms Devices System Access Areas Inputs OutputsProgram Menu Tree ExampleNtroduc tion FeaturesUser’s Guide Keypad Keys Reporting AlarmsAbout the Keypad For 2 secTo indicate you have exited Menu mode AlarmDon’t exit before the delay time expires and an Exit delay door is faulted, an alarm occursBasic System Operation Silencing AlarmsTurning An Area All On Press OK or Menu System ProgrammingChange Own PIN Enter New PIN forAdd PIN Change Other PINDelete PIN Add Keyfob Add TokenDelete Token Token StatusUser Name Delete KeyfobArea Assignment A001 Main Office Timer GroupAccess Assignment Area StatusTurn All Areas Off Area 1 NameTurn Area On/Off Turn All Areas OnA001 Reception Area  Chime On/OffArea Name Zone StatusZ002 Zone 2 Name Z003 Zone 3 Name Press  OK or Menu Bypass ZonesSet Chime Zones Z001 Zone 1 Name Zone Name Smoke Sensor ResetSmoke detector reset Progress. Please wait Set Part 2 ZonesWalk Test a Single Zone Walk Test All ZonesOutput Status Output 1 Name O001 Is on and Ready Press OK or Menu Turn Output On/OffOutput Name Output 1 Name O001 Is Off and Ready Press OK or MenuA002 Area 2 Name External Siren TestInternal Siren Test Strobe TestEmail System Log Call/Answer RASCall Forward On/Off Check Web EmailCall Forward Off Number Call Forward On NumberCustomer Contrast VolumeSend Test Report LAN StatusZ001 Zone 1 Name Keypad 001 Backlight Press OK to SavePanel Status System TroubleTrouble Condition Description Time History LogSet Date & Time NameStart / Stop Day DayKeypad Hi/Lo Temp Battery test Passed Press OK to continue Battery TestBattery test in progress Please wait If the battery has passed the test, the keypad will displayInstallation Details Areas NdexSmoke Detectors