Bosch Appliances 9 6 BLCC110U manual System Programming, Change Own PIN, Enter New PIN for

Page 9

Remote Arming - Quick Arm

If you forget to arm your system it may be possible for you to remotely arm it using a touch tone telephone if the remote arm option has been enabled by your installer.

To arm the system call the number which the panel is connected to and when the panel answer you will here 3 beeps in accending frequency if the panel is in the disarmed condition. Press [0] +

[#]to arm. You will hear 3 beeps in decending order when the panel arms.

All areas on the system will be armed regardless of there condition when using the DTMF quick arm function.

Duress or Silent alarms

A Duress or Silent Panic alarm can be easily triggered via the keypad if you are being forced to operate the system against your will.

To trigger a duress, enter your normal user PIN followed by the last 2 digits of your user PIN followed by the ON or OFF key. See the following examples.

1)If your PIN is 2580, to send a duress report when the area is off, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OK] or [ON].

2)If your PIN is 2580, to send a duress report when the area is on, Enter, [2] + [5] + [8] + [0] + [8] + [0] + [OFF].

System Programming

Some of the examples shown in the following section i assume that you are already in programming mode. Note To enter programming mode simply enter your PIN

and press the MENU key on the keypad.

Access > PIN Codes >

Change Own PIN

MENU 1-1-0

This menu lets you change your own PIN. It is recommended that you write down your old PIN and the new one before you begin. The new PIN must have the same number of digits as your old PIN unless your installer has enabled the variable length PIN option. Once the change is complete you should destroy the written copy.

At factory default, each PIN is fixed to 4 digits in length. The default PIN for User 1 (Master user) is 2580. Only the security installer can change the PIN length.

Enter programming mode (PIN + MENU) then,

1.Ensure that the system (or area) is turned off.

2.Enter your PIN, and then press [MENU] + [1] + [1] + [0].The keypad will prompt you to enter a new PIN.

Enter New PIN for

DEBBIE SMITH U002

Press OK or MENU

3.Enter your new PIN, and then press [OK]. If an error tone

Solution 64 User Guide

sounds, try a different PIN. The keypad will now prompt you to enter your new PIN again.

Confirm New PIN for

DEBBIE SMITH U002

Press OK or MENU

4.Enter your new PIN again.

5.Press [OK] to save and exit, or press [MENU] to exit without saving Your PIN has now been changed.

Programming Text Using The Keypad

When programming text via the keypad, various keys on the keypad operate differently.

A group of characters is assigned to each of the numeric keys on the keypad. Pressing the same numeric key again will toggle to the next character assigned to the key (eg. Press the [2] key will display the ‘A’ character, press the [2] key again will toggle to the ‘B’character, press the [2] key again will toggle to the‘C’character etc).

Once the correct character is display use the arrow keys to move to the next letter of the word you are entering.

The key assignments are identical to those found on most fixed and mobile phones.

When programming text, each numeric key represents a different group of characters.

Pressing the same numeric key repeatedly will step you through the available characters assigned to the key. The text key layout is the same as most phones. Refer to the table below for detailed character information.

Refer to the table below for more information.

Key

Characters Assigned To Each Numeric Key

 

1

.

,

?

!

-

&

`

1

 

2

A

B

C

a

b

c

2

 

 

3

D

E

F

d

e

f

3

 

 

4

G

H

I

g

h

i

4

 

 

5

J

K

L

j

k

l

5

 

 

6

M

N

O

m

n

o

6

 

 

7

P

Q

R

S

p

q

r

s

7

8

T

U

V

t

u

v

8

 

 

9

W

X

Y

Z

w

x

y

z

9

0

SPACE

0

 

 

 

 

 

 

 

Scroll Up through entire character list

Scroll Down through entire character list Move to left one character position

Move to right one character position

OFF Clear from cursor postiion to end of line

Table 4: Text Keypad Character Set

Once the desired character is displayed press the right [] arrow key to move to the next character position.To save programming changes, press [OK], or press [MENU] to exit without saving.

The

following

additional

 

special characters

are available

by

scrolling

using the

up and down

arrow keys.

+ - @ # $ “ & % *

: ( ) / < > =

 

Bosch Security Systems

 

09/06

 

BLCC110U

9

 

 

Image 9
Contents Solution Telepermit Note Copyright Notice TrademarksContents Program Menu Tree Access Areas Inputs OutputsExample Comms Devices SystemFeatures Ntroduc tionUser’s Guide About the Keypad Reporting AlarmsFor 2 sec Keypad KeysDon’t exit before the delay time expires and an AlarmExit delay door is faulted, an alarm occurs To indicate you have exited Menu modeSilencing Alarms Basic System OperationTurning An Area All On Change Own PIN System ProgrammingEnter New PIN for Press OK or MenuChange Other PIN Add PINDelete PIN Delete Token Add TokenToken Status Add KeyfobDelete Keyfob User NameArea Assignment Access Assignment Timer GroupArea Status A001 Main OfficeTurn Area On/Off Area 1 NameTurn All Areas On Turn All Areas OffArea Name Chime On/OffZone Status A001 Reception Area Set Chime Zones Bypass ZonesZ001 Zone 1 Name  Z002 Zone 2 Name Z003 Zone 3 Name Press  OK or MenuSmoke detector reset Progress. Please wait Smoke Sensor ResetSet Part 2 Zones Zone NameWalk Test All Zones Walk Test a Single ZoneOutput Status Output Name Turn Output On/OffOutput 1 Name O001 Is Off and Ready Press OK or Menu Output 1 Name O001 Is on and Ready Press OK or MenuInternal Siren Test External Siren TestStrobe Test A002 Area 2 NameCall Forward On/Off Call/Answer RASCheck Web Email Email System LogCall Forward On Number Call Forward Off NumberCustomer Send Test Report VolumeLAN Status ContrastPanel Status Keypad 001 Backlight Press OK to SaveSystem Trouble Z001 Zone 1 NameTrouble Condition Description Set Date & Time History LogName TimeDay Start / Stop DayKeypad Hi/Lo Temp Battery test in progress Please wait Battery TestIf the battery has passed the test, the keypad will display Battery test Passed Press OK to continueInstallation Details Areas NdexSmoke Detectors