Bosch Appliances 9 6 BLCC110U manual Copyright Notice Trademarks, Telepermit Note

Page 2

Solution 64 User Guide

Copyright Notice

Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd (“Bosch”). All rights are reserved.You may download a single copy of this publication. By downloading the publication you agree that you will: (i) only use the publication for your own reference; (ii) not commercially exploit or charge any person for the use of the publication; and (iii) not modify the publication in any way without the prior written permission of Bosch. Except as specified above or where authorised by the Copyright Act 1968 (Cth), no part of this publication may be reproduced, transmitted, modified or stored in any form or by any means, without the prior written permission of Bosch.

Trademarks

Throughout this document trademark names may have been used. Rather than put a trademark symbol in every occurrence of a trademark name, we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the trademark.

Notice of Liability

While every effort has been taken the accuracy of this document, neither Bosch Security Systems Pty Ltd nor any of its official representatives shall have any liability to any person or entity with respect to any liability, loss or damage caused or alleged to be caused directly or indirectly by the information contained in this book. Should you find any error on inconsistency, please notify us accordingly.

Bosch Security Systems Pty Ltd reserves the right to make changes to features and specifications at any time without prior notification in the interest of ongoing product development and improvement.

Telepermit Note

The grant of a Telepermit for a device in no way indicates Telecom acceptance of responsibility for the correct operation of that device under all operating conditions.

This equipment shall not be used in any manner that could constitute a nuisance to other Telecom customers.

Immediately disconnect this equipment should it become physically damaged, and arrange for its disposal or repair.

Thetransmitlevelfromthisdeviceissetasafixedlevelandbecause of this there may be circumstances where the performance is less than optimal. Before reporting such occurrences as faults, please check the line with a standard telepermitted telephone.

Warnings

1)This product must be installed by a qualified and licensed security installer.

2)This product may not perform as expected if installed incorrectly.

3)Some features of this product require a working telephone line to operate and telephone communication service provider charges may be applicable.

4)Australian standard AS 2201 require regular service by qualified and licensed security persons and regular user testing. Please consult your security alarm company for further details.

5)Incorrect programming of options can result in operation contrary to what may be desired.

6)Leave the mains adapter plugged in at all times.

7)Leave the telephone line plugged in at all times under normal conditions.

Notice to Owner

Thankyou for selecting the Solution 64 Security Control Panel for your security needs.Your system includes many advanced features and functions which will be programmed and configured by your security consultant during installation. Depending on the configuration, and your access level, you may have the ability to program certain features within the system to suit changes in your security needs. For example you may wish to change a User Name or PIN number when a staff member leaves.

This manual explains all aspects of system operation as well as detailling the various programming options available to you. We ask that you take the time to read this manual carefully and that you have your installer explain the basic system operation and configuration to you when the installation is complete.

2

Bosch Security Systems

09/06

BLCC110U

Image 2
Contents Solution Copyright Notice Trademarks Telepermit NoteContents Example Access Areas Inputs OutputsProgram Menu Tree Comms Devices SystemUser’s Guide FeaturesNtroduc tion For 2 sec Reporting AlarmsAbout the Keypad Keypad KeysExit delay door is faulted, an alarm occurs AlarmDon’t exit before the delay time expires and an To indicate you have exited Menu modeTurning An Area All On Silencing AlarmsBasic System Operation Enter New PIN for System ProgrammingChange Own PIN Press OK or MenuDelete PIN Change Other PINAdd PIN Token Status Add TokenDelete Token Add KeyfobArea Assignment Delete KeyfobUser Name Area Status Timer GroupAccess Assignment A001 Main OfficeTurn All Areas On Area 1 NameTurn Area On/Off Turn All Areas OffZone Status Chime On/OffArea Name A001 Reception Area Z001 Zone 1 Name  Bypass ZonesSet Chime Zones Z002 Zone 2 Name Z003 Zone 3 Name Press  OK or MenuSet Part 2 Zones Smoke Sensor ResetSmoke detector reset Progress. Please wait Zone NameOutput Status Walk Test All ZonesWalk Test a Single Zone Output 1 Name O001 Is Off and Ready Press OK or Menu Turn Output On/OffOutput Name Output 1 Name O001 Is on and Ready Press OK or MenuStrobe Test External Siren TestInternal Siren Test A002 Area 2 NameCheck Web Email Call/Answer RASCall Forward On/Off Email System LogCustomer Call Forward On NumberCall Forward Off Number LAN Status VolumeSend Test Report ContrastSystem Trouble Keypad 001 Backlight Press OK to SavePanel Status Z001 Zone 1 NameTrouble Condition Description Name History LogSet Date & Time TimeKeypad Hi/Lo Temp DayStart / Stop Day If the battery has passed the test, the keypad will display Battery TestBattery test in progress Please wait Battery test Passed Press OK to continueInstallation Details Ndex AreasSmoke Detectors