Bosch Appliances 9 6 BLCC110U manual History Log, Set Date & Time, Sk001 Schedule 1 Name

Page 26

Solution 64 User Guide

System > Commands >

History Log

MENU 7-0-2

This menu allows you to review the last 256 history events (from most recent to least recent).

Each event will display:

Line 1 - Displays Event Number

-Date / Time

-Destination 1 and/or 2 report status (S= Sent, P = Pending, F = Fail, A = Abort and L = Log Only).

Line 2 - Displays the source of the event (eg. zone name and zone number or user name and user number)

Line 3 - Displays the event description.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [0] + [2].

The keypad will display the most recent event stored in the history log.

E001 Mon,01Oct 03:41 S1L2

Manual Test Report

Press  OK or MENU

2.Use the [] and [] keys scroll between history events.

3.Press [OK] or [MENU] to exit.

System > Clock >

Set Date & Time

MENU 7-1-0

This menu allows you to program/adjust the date and time in the Solution 64 control panel.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [1] + [0].

The keypad will display the current date and time.

Set Date And Time

01-Jan-2004 04:37am

Press ◄► OK to SAVE

2.Use the [] and [] keys to program the month, day, year, hour and minute. Use [] and [] keys to scroll cursor left and right to between the month, day, year, hour and minute.

3.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > Schedules >

Name

MENU 7-5-0

This menu allows you to program 16 characters of text for each schedule name.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [7] + [5] + [0].

A list of schedules will display on the keypad.

Sk001 Schedule 1 Name

Sk002 Schedule 2 Name

Sk003 Schedule 3 Name

Press  OK or MENU

2.Use the [] and [] keys to select the schedule name that you want to change, then press [OK] to select. Alternatively, you can enter the schedule number, then press [OK].

The keypad will display the following:

Name S001

Schedule 1 Name

PRESS ◄► OK to SAVE

3.To program the schedule name, use the [] and [] keys to scroll the cursor left and right across the user name text. Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > Schedules >

Time

MENU 7-5-1

This menu allows you to program both the start time and stop time of each schedule.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [7] + [6] + [2].

A list of schedules will display on the keypad.

Sk001 Schedule 1 Name

Sk002 Schedule 2 Name

Sk003 Schedule 3 Name

Press  OK or MENU

2.Use the [] and [] keys to select the schedule that you want to change, then press [OK] to select. Alternatively, you can enter the schedule number, then press [OK].

The keypad will display the following:

Sk001 Schedule 1 Name

Start Time: 00:00

Stop Time: 00:00

Press 0-9 OK to SAVE

26

Bosch Security Systems

09/06

BLCC110U

Image 26
Contents Solution Copyright Notice Trademarks Telepermit NoteContents Example Access Areas Inputs OutputsProgram Menu Tree Comms Devices SystemUser’s Guide FeaturesNtroduc tion For 2 sec Reporting AlarmsAbout the Keypad Keypad KeysExit delay door is faulted, an alarm occurs AlarmDon’t exit before the delay time expires and an To indicate you have exited Menu modeTurning An Area All On Silencing AlarmsBasic System Operation Enter New PIN for System ProgrammingChange Own PIN Press OK or MenuDelete PIN Change Other PINAdd PIN Token Status Add TokenDelete Token Add KeyfobArea Assignment Delete KeyfobUser Name Area Status Timer GroupAccess Assignment A001 Main OfficeTurn All Areas On Area 1 NameTurn Area On/Off Turn All Areas OffZone Status Chime On/OffArea Name A001 Reception Area Z001 Zone 1 Name  Bypass ZonesSet Chime Zones Z002 Zone 2 Name Z003 Zone 3 Name Press  OK or MenuSet Part 2 Zones Smoke Sensor ResetSmoke detector reset Progress. Please wait Zone NameOutput Status Walk Test All ZonesWalk Test a Single Zone Output 1 Name O001 Is Off and Ready Press OK or Menu Turn Output On/OffOutput Name Output 1 Name O001 Is on and Ready Press OK or MenuStrobe Test External Siren TestInternal Siren Test A002 Area 2 NameCheck Web Email Call/Answer RASCall Forward On/Off Email System LogCustomer Call Forward On NumberCall Forward Off Number LAN Status VolumeSend Test Report ContrastSystem Trouble Keypad 001 Backlight Press OK to SavePanel Status Z001 Zone 1 NameTrouble Condition Description Name History LogSet Date & Time TimeKeypad Hi/Lo Temp DayStart / Stop Day If the battery has passed the test, the keypad will display Battery TestBattery test in progress Please wait Battery test Passed Press OK to continueInstallation Details Ndex AreasSmoke Detectors