3.Enter the new start and stop times in 24-hour format (00:00 to 23:59 hours).

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > Schedules >

Day

MENU 7-5-2

This menu programs which days of the week the timer execute function will operate. To toggle the day of the week on/off, press the corresponding number on the keypad (e.g. to turn Monday on, press [2] + [OK], to toggle Monday off, press [2] + [OK] ).

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [7] + [5] + [2].

A list of schedules will display on the keypad.

Sk001 Schedule 1 Name

Sk002 Schedule 2 Name

Sk003 Schedule 3 Name

Press  OK or MENU

2.Use the [] and [] keys to select the schedule that you want to change, then press [OK] to select. Alternatively, you can enter the schedule number, then press [OK].

The keypad will display the following:

Day Sk001

S M T W T F S Hol

Y Y Y Y Y Y Y N

Press 1-8 OK to SAVE

3.Press [1] to [8] to enable/disable the days of the week that the schedule will operate.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > Holidays >

Name

MENU 7-6-0

This menu allows you to program 16 characters for the holiday name.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [7] + [0] + [6].

A list of holiday names will display on the keypad.

2.Use the [] and [] keys to select the timer name that you want to change, then press [OK] to select. Alternatively, you can enter the timer number, then press [OK].

The keypad will display the following:

Name H001

Holiday 1 Name

PRESS ◄► OK to SAVE

3.To program the holiday name, use the [] and [] keys to scroll the cursor left and right across the user name text.

Solution 64 User Guide

Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > Holidays >

Start / Stop Day

MENU 7-6-1

This menu allows you to program the start date and the stop date of each holiday period.

Enter programming mode (PIN + MENU) then,

1.Enter [MENU] + [7] + [6] + [1].

A list of holiday names will display on the keypad.

2.Use the [] and [] keys to select the holiday that you want to change, then press [OK] to select. Alternatively, you can enter the holiday number, then press [OK].

The keypad will display the holiday start date:

Holiday Dates H001

Start Date

Stop Date

01 Jan

01 Jan

Press ◄► OK to SAVE

3.To program the holiday start date and stop date, use the [] and [] keys to scroll the cursor left and right between the holiday day and month. Use the [] and [] keys to scroll the day and month.

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > System Options >

Keypad Hi/Lo Temp

MENU 7-7-3

The keypad Hi/Lo temperature allows you to program the minimum (0 °C) and maximum (50 °C) temperatures the keypad will monitor (tolerance = +/- 2 °C).

If the temperature falls below the minimum temperature, the keypad will display ‘Low Temp ˚xx’. If the temperature increases above the maximum temperature, the keypad will display ‘High temp ˚xx’.

(xx = programmed temperature to be monitored). Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [7] + [3].

The keypad will display the current temperature settings.

Keypad Hi/Lo Temp

High Temp

Low Temp

00

00

Press ◄► OK to SAVE

2.Use the [] and [] keys to program the ‘High’ and ‘Low’ temperatures. To toggle between the ‘High’ and ‘Low’ temperature, use the [] and [] keys (Range = 0°C to 50°C).

3.Press [OK] to save and exit, or press [MENU] to exit without saving.

Bosch Security Systems

 

09/06

 

BLCC110U

27

 

 

Image 27
Contents Solution Telepermit Note Copyright Notice TrademarksContents Comms Devices System Access Areas Inputs OutputsProgram Menu Tree ExampleFeatures Ntroduc tionUser’s Guide Keypad Keys Reporting AlarmsAbout the Keypad For 2 secTo indicate you have exited Menu mode AlarmDon’t exit before the delay time expires and an Exit delay door is faulted, an alarm occursSilencing Alarms Basic System OperationTurning An Area All On Press OK or Menu System ProgrammingChange Own PIN Enter New PIN forChange Other PIN Add PINDelete PIN Add Keyfob Add TokenDelete Token Token StatusDelete Keyfob User NameArea Assignment A001 Main Office Timer GroupAccess Assignment Area StatusTurn All Areas Off Area 1 NameTurn Area On/Off Turn All Areas OnA001 Reception Area  Chime On/OffArea Name Zone StatusZ002 Zone 2 Name Z003 Zone 3 Name Press  OK or Menu Bypass ZonesSet Chime Zones Z001 Zone 1 Name Zone Name Smoke Sensor ResetSmoke detector reset Progress. Please wait Set Part 2 ZonesWalk Test All Zones Walk Test a Single ZoneOutput Status Output 1 Name O001 Is on and Ready Press OK or Menu Turn Output On/OffOutput Name Output 1 Name O001 Is Off and Ready Press OK or MenuA002 Area 2 Name External Siren TestInternal Siren Test Strobe TestEmail System Log Call/Answer RASCall Forward On/Off Check Web EmailCall Forward On Number Call Forward Off NumberCustomer Contrast VolumeSend Test Report LAN StatusZ001 Zone 1 Name Keypad 001 Backlight Press OK to SavePanel Status System TroubleTrouble Condition Description Time History LogSet Date & Time NameDay Start / Stop DayKeypad Hi/Lo Temp Battery test Passed Press OK to continue Battery TestBattery test in progress Please wait If the battery has passed the test, the keypad will displayInstallation Details Areas NdexSmoke Detectors