Solution 64 User Guide

System > System Testing >

Walk Test All Zones

MENU 7-9-0

This menu allows you to test all zones within an area at the same time.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [9] + [0].

The keypad will display a list of areas that are available to walk test zones.

2.Use the [] and [] keys to select the area that you want to do walk test, then press [OK] to select. Alternatively, you can enter the area number, then press [OK].

The keypad will scroll all zones that you can test.

To test Z001 open then close Zone 1 Name

Press OK or MENU

To test Z002 open then close Zone 1 Name

Press OK or MENU

3.Open and close each zone that needs to be tested. A zone that has been successfully tested will no longer scroll on the keypad display.

When all zones have been tested, the keypad will display:

Selected zones have been

Tested OK

Press OK or MENU

4.Press [OK] to save and exit, or press [MENU] to exit without saving.

System > System Testing >

Battery Test

MENU 7-9-1

This menu allows you to manually test the systems back up battery. The Solution 64 will automatically test the battery once per day and every time the system is armed.

The battery test can take up to two minutes to complete and the keypad will display the voltage of the battery during the test.

Enter programming mode (PIN + MENU) then,

1.Press [MENU] + [7] + [9] + [2].

The keypad will display the battery voltage whilst under test:

Battery test in progress.

Please wait..

Voltage = 13.4V

To Go Back Press OK

If the battery has passed the test, the keypad will display:

Battery test Passed.

Press OK to continue

If the battery has failed the test, the keypad will display:

Battery test Failed.

Please Call for Service.

Press OK to continue

2.Press [OK] to exit.

28

Bosch Security Systems

09/06

BLCC110U

Image 28
Contents Solution Copyright Notice Trademarks Telepermit NoteContents Access Areas Inputs Outputs Program Menu TreeExample Comms Devices SystemNtroduc tion FeaturesUser’s Guide Reporting Alarms About the KeypadFor 2 sec Keypad KeysAlarm Don’t exit before the delay time expires and anExit delay door is faulted, an alarm occurs To indicate you have exited Menu modeBasic System Operation Silencing AlarmsTurning An Area All On System Programming Change Own PINEnter New PIN for Press OK or MenuAdd PIN Change Other PINDelete PIN Add Token Delete TokenToken Status Add KeyfobUser Name Delete KeyfobArea Assignment Timer Group Access AssignmentArea Status A001 Main OfficeArea 1 Name Turn Area On/OffTurn All Areas On Turn All Areas OffChime On/Off Area NameZone Status A001 Reception Area Bypass Zones Set Chime ZonesZ001 Zone 1 Name  Z002 Zone 2 Name Z003 Zone 3 Name Press  OK or MenuSmoke Sensor Reset Smoke detector reset Progress. Please waitSet Part 2 Zones Zone NameWalk Test a Single Zone Walk Test All ZonesOutput Status Turn Output On/Off Output NameOutput 1 Name O001 Is Off and Ready Press OK or Menu Output 1 Name O001 Is on and Ready Press OK or MenuExternal Siren Test Internal Siren TestStrobe Test A002 Area 2 NameCall/Answer RAS Call Forward On/OffCheck Web Email Email System LogCall Forward Off Number Call Forward On NumberCustomer Volume Send Test ReportLAN Status ContrastKeypad 001 Backlight Press OK to Save Panel StatusSystem Trouble Z001 Zone 1 NameTrouble Condition Description History Log Set Date & TimeName TimeStart / Stop Day DayKeypad Hi/Lo Temp Battery Test Battery test in progress Please waitIf the battery has passed the test, the keypad will display Battery test Passed Press OK to continueInstallation Details Ndex AreasSmoke Detectors