Kenmore Official Water Heater Manual: Model Numbers and Repair Parts

Page 42

KENMORE 12 YEAR GAS WATER HEATER

153.331140

40

Gallon

(Natural)

153.331150

50 Gallon

(Natural)

Key No. Part Description

1 Anode Rod

2Anode Rod (Secondary)

3Base-Ring Filter

4Burner Head

5Burner Orifice

6 Draft Hood

7Drain Valve

8 Gas Control Valve/Thermostat

9 Inlet Tube w/Gasket

10 Inner Door Gasket *

11 Instruction Manual *

12 Manifold Door Assembly - Con- tains: Manifold Tube, Gasket, Door, Pilot Tube, Thermopile, Manifold Component Block, Thermal Switch, Burner Head

Burner Onfice and PilotAssembly.

13Nipple w/Heat Trap

14Outer Door

15Pilot Assembly w/Tubing and Fittings

16r & P Relief Valve

17Thermopile

18Manifold Component Block w/Clip

Not Shown.

f--._

/2_ ¸i_

Model

Numbers

153.331140

153.331150

9003721

9001829

9003934

9003934

9006616

9006660

9006136

9006136

9006698

9006698

9006647

9006647

9000058

9000058

9007885

9007885

9003473

9006653

9006141

9006141

320391-000

320391-000

9007899

9007908

9003719

9003719

9006648

9006648

9007876

9007876

9000728

9000728

9007872

9007872

9006449

9006449

Now that you have purchased your gas water heater, should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY-HOME ® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit.

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:

MODEL NUMBER

SERIAL NUMBER

TYPE GAS - NATURAL OR PROPANE (L.R)

PART DESCRIPTION

THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST.

42

Image 42
Contents 153.331140 40 Gallon 153.331150 50 Gallon Sears Brands Management CorporationModel No 320391-000Read and follow water heater warnings and instructions Important DefinitionsFire Hazard Improper installation and use may result in property damageFire or Explosion Hazard Explosion HazardVent Connectors 19-20 InstallationVent Pipe System Draft Hood Installation 12-15LightingInstructions OperatingtheTemperatureControlSystemService StartUpConditionsYear Limited Warranty on Water Heater Excessive Weight Hazard Important Information About This Water HeaterModel Materials Needed Vent Pipe Inner Door Control/Temperature KnobTemperatures shown are approximates and may vary Status Mark LightInstallation Checklist Removing the Old Water Heater Manual GASCarbon Monoxide Poisoning Hazard Location RequirementsSite Location Fire or Explosion HazardBreathing Hazard Carbon Monoxide Gas Insulation BlanketsProperty Damage Hazard All water heaters eventually leakGas Piping Filling the Water HeaterGas Requirements Property Damage HazardLP Gas Only Gas Pressure TestingGas Pressure Explosion HazardAll Air from Inside the Building Carbon Monoxide WarningUnconfined Space Confined SpaceAll Air from Outdoors Louvers and GrillesVent Pipe Size Draft Hood InstallationVent Connectors Vent Pipe SystemChimney as it may restrict the space between it Chimney ConnectionVertical Exhaust Gas Vent Opposite wall of the chimney FigurePiping Installation Isectn 19 MGLLminimum Temperature and Pressure Relief Valve Closed System/Thermal ExpansionIf the Status Light Does Not Blink Lighting InstructionsLighting the Pilot If the Pilot Does Not LightPhone. Follow the gas supptiersinstructions STOP!It is imyou readall safety lightingthe pilotRefertothe UghtingInstructionsinthe Installation IgniterGASCONTROLBurner Flames Water Temperature RegulationChecking the Draft Emergency Shut DownOperating the Temperature Control System Status Light Code Normal FlashesCarbon Monoxide and Fire Hazard Vent System InspectionBurner Inspection Fiue gases may escape if ,vent pipe is not connectedDraining and Flushing HousekeepingAnode Rod Inspection Fire and Explosion HazardService Removing the Manifold/Burner Assembly Replacement PartsExternal Inspection & Cleaning Base-Ring Filter Removing the Burner from the Manifold Burner AssemblyCleaning the Combustion Chamber and Flame-arrestor Burneran otherReplacing the Manifold/Burner Assembly Explosion HazardPiezoelectric Igniter System Removing and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatStart Up Conditions Thermal Ex ansion Tank SpecificationsExpansion Tank Sizing Chart Strange SoundsCondensation Safety Shut-off and Thermal SwitchOperational Conditions AIR In Hot Water FaucetsBefore installing, operating or servicing this water heater Problem Excessive Waterpressure Use Pressure Reducing Valve Water heater flue or vent systemBlocked Thermostat Not functioning properly Replace Down Pilot light was recently extinguished Thermopile is cooling Normal OperationTemperature Sensor Thermistor Is defective Gas Control Valve failure=N01 800-4694663Section Pilot light Repeatedly Goes out 153.331140 Gallon 153.331150 GallonModel Page MY-HOME