Kenmore 153.33115 Operating the Temperature Control System, Status Light Code Normal Flashes

Page 26

120°F

Gas Control/Temperature Knob Status Mark

Igniter

Temperatures shown are approximates and may vary.

IMPORTANT: Adjusting the thermostat past the 120°F bar on the temperature dial wilt increase the risk of scald injury. Hot water can produce first degree burns within:

110

(normal shower temp.)

 

116

(pain

threshold)

 

116

35 minutes

45 minutes

122

1 minute

5 minutes

131

5

seconds

25 seconds

140

2

seconds

5 seconds

149

1 second

2 seconds

154

instantaneous

1 second

(U.S. GovernmentMemorandum,C.P.S.C.,PeterL Armstrong,Sept. 15,1978)

FIGURE 28.

NOTE: During tow demand periods when hot water is not being used, a lower thermostat setting wilt reduce energy losses and may satisfy your normal hot water needs. If hot water use is expected to be more than normal, a higher thermostat setting may be required to meet the increased demand. When leaving your home for extended periods (vacations, etc.) turn the temperature dial to its lowest setting. This wilt maintain the water at tow temperatures with minimum energy losses and prevent the tank from freezing during cold weather.

Operating the Temperature Control System

List of status codes are shown

at top of gas control valve/thermostat.

C

FIGURE 29.

Water Temperature Adjustment

The water temperature setting can be adjusted from 55°F to 155°F. Turn the Gas Control/Temperature Knob to the desired setting/temperature.

NOTE: Some models are certified for 180°F outlet temperatures. See the Data Plate on the front of the water heater for the maximum outlet temperature.

NOTE: The temperatures indicated are approximates. The actual temperature of the heated water may vary.

Operating Modes and Settings

Standard Mode - The controller adjusts the water heater to maintain the temperature set by the user.

The Vacation Setting (VAC) sets the controller at approximately 55°F. This setting is recommended when the water heater is not in use for a long period of time. This effectively turns the controller temperature setting down to a temperature that prevents the water in the water heater from freezing while still conserving energy.

Status Light Code

Normal Flashes:

0 Flashes Indicates Control Off/Pilot Out.

1 Flash Indicates Normal Operation.

A Solid Red Light indicates the gas control valve/thermostat is shutting down.

Diagnostic Flashes: If the water heater is not working look for the following diagnostic flashes after lighting the pilot. For more details see the "Status Light and Diagnostic Code Troubleshooting Chart."

2 Flashes Indicates Thermopite Voltage Low

4 Flashes Indicates Overheat Failure

5 Flashes Indicates Sensor Failure

7 Flashes Indicates Electronic Control Failure

8 Flashes See "Status Light and Diagnostic Code

Troubleshooting Chart."

26

Image 26
Contents 153.331140 40 Gallon 153.331150 50 Gallon Sears Brands Management CorporationModel No 320391-000Read and follow water heater warnings and instructions Important DefinitionsFire Hazard Improper installation and use may result in property damageFire or Explosion Hazard Explosion HazardVent Connectors 19-20 InstallationVent Pipe System Draft Hood Installation 12-15LightingInstructions OperatingtheTemperatureControlSystemService StartUpConditionsYear Limited Warranty on Water Heater Excessive Weight Hazard Important Information About This Water HeaterModel Materials Needed Vent Pipe Inner Door Control/Temperature KnobTemperatures shown are approximates and may vary Status Mark LightInstallation Checklist Removing the Old Water Heater Manual GASCarbon Monoxide Poisoning Hazard Location RequirementsSite Location Fire or Explosion HazardBreathing Hazard Carbon Monoxide Gas Insulation BlanketsProperty Damage Hazard All water heaters eventually leakGas Piping Filling the Water HeaterGas Requirements Property Damage HazardLP Gas Only Gas Pressure TestingGas Pressure Explosion HazardAll Air from Inside the Building Carbon Monoxide WarningUnconfined Space Confined SpaceAll Air from Outdoors Louvers and GrillesVent Pipe Size Draft Hood InstallationVent Connectors Vent Pipe SystemChimney as it may restrict the space between it Chimney ConnectionVertical Exhaust Gas Vent Opposite wall of the chimney FigureLminimum Piping InstallationIsectn 19 MGL Temperature and Pressure Relief Valve Closed System/Thermal ExpansionIf the Status Light Does Not Blink Lighting InstructionsLighting the Pilot If the Pilot Does Not LightPhone. Follow the gas supptiersinstructions STOP!It is imyou readall safety lightingthe pilotRefertothe UghtingInstructionsinthe Installation IgniterGASCONTROLBurner Flames Water Temperature RegulationChecking the Draft Emergency Shut DownOperating the Temperature Control System Status Light Code Normal FlashesCarbon Monoxide and Fire Hazard Vent System InspectionBurner Inspection Fiue gases may escape if ,vent pipe is not connectedDraining and Flushing HousekeepingAnode Rod Inspection Fire and Explosion HazardService Removing the Manifold/Burner Assembly Replacement PartsExternal Inspection & Cleaning Base-Ring Filter Removing the Burner from the Manifold Burner AssemblyCleaning the Combustion Chamber and Flame-arrestor Burneran otherPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyExplosion Hazard Removing and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatStart Up Conditions Thermal Ex ansion Tank SpecificationsExpansion Tank Sizing Chart Strange SoundsCondensation Safety Shut-off and Thermal SwitchOperational Conditions AIR In Hot Water FaucetsBefore installing, operating or servicing this water heater Problem Excessive Waterpressure Use Pressure Reducing Valve Water heater flue or vent systemBlocked Thermostat Not functioning properly ReplaceDown Pilot light was recently extinguishedThermopile is cooling Normal OperationTemperature Sensor Thermistor Is defective Gas Control Valve failureSection Pilot light Repeatedly Goes out =N01800-4694663 Model 153.331140 Gallon153.331150 Gallon Page MY-HOME

153.33114, 153.33115 specifications

The Kenmore 153.33115 and 153.33114 are high-efficiency dehumidifiers designed to effectively manage moisture levels in residential spaces, providing comfort and safeguarding homes against the damaging effects of excess humidity. Both models embody Kenmore's commitment to quality, innovative technologies, and user-friendly features, making them ideal choices for maintaining optimal indoor air quality.

One of the standout features of the Kenmore 153.33115 and 153.33114 is their powerful dehumidification capability. With the capacity to remove up to 70 pints of moisture per day, these dehumidifiers efficiently tackle dampness in areas of up to 1,500 square feet. This makes them suitable for various spaces, including basements, laundry rooms, and even larger living areas, ensuring a healthy environment free from mold and mildew growth.

The models are equipped with an adjustable humidistat, which allows users to set their desired humidity levels easily. This feature not only enhances user control but also ensures energy efficiency by allowing the machines to operate only when necessary. Alongside energy efficiency, these dehumidifiers are designed to comply with Department of Energy guidelines, making them an eco-friendly choice.

Both models also feature a continuous drainage option, enabling hassle-free operation without the need for constant manual emptying of the water tank. When the water tank reaches capacity, an automatic shut-off function prevents overflow, ensuring peace of mind for users.

In terms of convenience, the Kenmore 153.33115 and 153.33114 have a user-friendly digital control panel with an easy-to-read LED display. This intuitive interface makes it simple to adjust settings, check humidity levels, and monitor overall performance. Additionally, the inclusion of wheels and a lightweight design enhances portability, allowing users to move the dehumidifiers where they are needed most.

Another notable aspect is the enhanced air filtration system. These dehumidifiers come with a removable, washable filter that effectively captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

In conclusion, the Kenmore 153.33115 and 153.33114 are exemplary dehumidifiers that combine efficient moisture removal, user-friendly features, and eco-conscious designs. With their robust performance, effective humidity control, and added convenience features, these models stand out as reliable solutions for maintaining a comfortable and healthy indoor environment.