Kenmore 153.33114, 153.33115 LightingInstructions, OperatingtheTemperatureControlSystem, Service

Page 5

OPERATINGYOURWATERHEATER

23-26

LightingInstructions

23-24

CheckingtheDraft

25

BurnerFlames

25

EmergencyShutDown

25

WaterTemperatureRegulation

25-26

OperatingtheTemperatureControlSystem

26

SERVICEANDADJUSTMENT

27-29

VentSystemInspection

27

BurnerInspection

27

BurnerCleaning

27

Housekeeping

28

AnodeRodInspection

28

Temperature-PressureReliefValveOperation

28

DrainingandFlushing

28-29

Service

29

MAINTENANCEOFYOURWATERHEATER

30-33

ReplacementParts

30

ExternalInspection& Cleaningof theBase-RingFilter

30

RemovingtheManifold/BurnerAssembly

30

RemovingtheBurnerfromtheManifold/BurnerAssembly

30

ReplacingtheThermopile

30-31

ReplacingthePilot/PilotTubeAssembly

31

CleaningtheCombustionChamberandFlame-arrestor

31

ReplacingtheManifold/BurnerAssembly

32

PiezoelectricIgniterSystem

32

TestingtheIgniterSystem

32

RemovingandReplacingtheGasControlValve/Thermostat

33

FVlRSystemOperationalChecklist

33

TROUBLESHOOTINGGUIDE

34-36

StartUpConditions

34-35

OperationalConditions

35-36

TROUBLESHOOTINGCHART

37-38

STATUSLIGHTAND DIAGNOSTICTROUBLESHOOTINGCHART

39-40

PILOTLIGHTTROUBLESHOOTINGFLOWCHART

41

PARTSORDERLIST

42-43

NOTES

44-47

Image 5
Contents Model No Sears Brands Management Corporation153.331140 40 Gallon 153.331150 50 Gallon 320391-000Important Definitions Read and follow water heater warnings and instructionsFire or Explosion Hazard Improper installation and use may result in property damageFire Hazard Explosion HazardVent Pipe System Draft Hood Installation InstallationVent Connectors 19-20 12-15Service OperatingtheTemperatureControlSystemLightingInstructions StartUpConditionsYear Limited Warranty on Water Heater Important Information About This Water Heater Excessive Weight HazardModel Materials Needed Temperatures shown are approximates and may vary Control/Temperature KnobVent Pipe Inner Door Status Mark LightInstallation Checklist Manual GAS Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Fire or Explosion HazardProperty Damage Hazard Insulation BlanketsBreathing Hazard Carbon Monoxide Gas All water heaters eventually leakGas Requirements Filling the Water HeaterGas Piping Property Damage HazardGas Pressure Gas Pressure TestingLP Gas Only Explosion HazardUnconfined Space Carbon Monoxide WarningAll Air from Inside the Building Confined SpaceLouvers and Grilles All Air from OutdoorsVent Connectors Draft Hood InstallationVent Pipe Size Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionChimney as it may restrict the space between it Opposite wall of the chimney FigureLminimum Piping InstallationIsectn 19 MGL Closed System/Thermal Expansion Temperature and Pressure Relief ValveLighting the Pilot Lighting InstructionsIf the Status Light Does Not Blink If the Pilot Does Not LightRefertothe UghtingInstructionsinthe Installation STOP!It is imyou readall safety lightingthe pilotPhone. Follow the gas supptiersinstructions IgniterGASCONTROLChecking the Draft Water Temperature RegulationBurner Flames Emergency Shut DownStatus Light Code Normal Flashes Operating the Temperature Control SystemBurner Inspection Vent System InspectionCarbon Monoxide and Fire Hazard Fiue gases may escape if ,vent pipe is not connectedAnode Rod Inspection HousekeepingDraining and Flushing Fire and Explosion HazardService External Inspection & Cleaning Base-Ring Filter Replacement PartsRemoving the Manifold/Burner Assembly Removing the Burner from the Manifold Burner AssemblyBurneran other Cleaning the Combustion Chamber and Flame-arrestorPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyExplosion Hazard Removing the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatExpansion Tank Sizing Chart Thermal Ex ansion Tank SpecificationsStart Up Conditions Strange SoundsOperational Conditions Safety Shut-off and Thermal SwitchCondensation AIR In Hot Water FaucetsBefore installing, operating or servicing this water heater Problem Blocked Water heater flue or vent systemExcessive Waterpressure Use Pressure Reducing Valve Thermostat Not functioning properly ReplaceThermopile is cooling Pilot light was recently extinguishedDown Normal OperationGas Control Valve failure Temperature Sensor Thermistor Is defectiveSection Pilot light Repeatedly Goes out =N01800-4694663 Model 153.331140 Gallon153.331150 Gallon Page MY-HOME

153.33114, 153.33115 specifications

The Kenmore 153.33115 and 153.33114 are high-efficiency dehumidifiers designed to effectively manage moisture levels in residential spaces, providing comfort and safeguarding homes against the damaging effects of excess humidity. Both models embody Kenmore's commitment to quality, innovative technologies, and user-friendly features, making them ideal choices for maintaining optimal indoor air quality.

One of the standout features of the Kenmore 153.33115 and 153.33114 is their powerful dehumidification capability. With the capacity to remove up to 70 pints of moisture per day, these dehumidifiers efficiently tackle dampness in areas of up to 1,500 square feet. This makes them suitable for various spaces, including basements, laundry rooms, and even larger living areas, ensuring a healthy environment free from mold and mildew growth.

The models are equipped with an adjustable humidistat, which allows users to set their desired humidity levels easily. This feature not only enhances user control but also ensures energy efficiency by allowing the machines to operate only when necessary. Alongside energy efficiency, these dehumidifiers are designed to comply with Department of Energy guidelines, making them an eco-friendly choice.

Both models also feature a continuous drainage option, enabling hassle-free operation without the need for constant manual emptying of the water tank. When the water tank reaches capacity, an automatic shut-off function prevents overflow, ensuring peace of mind for users.

In terms of convenience, the Kenmore 153.33115 and 153.33114 have a user-friendly digital control panel with an easy-to-read LED display. This intuitive interface makes it simple to adjust settings, check humidity levels, and monitor overall performance. Additionally, the inclusion of wheels and a lightweight design enhances portability, allowing users to move the dehumidifiers where they are needed most.

Another notable aspect is the enhanced air filtration system. These dehumidifiers come with a removable, washable filter that effectively captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

In conclusion, the Kenmore 153.33115 and 153.33114 are exemplary dehumidifiers that combine efficient moisture removal, user-friendly features, and eco-conscious designs. With their robust performance, effective humidity control, and added convenience features, these models stand out as reliable solutions for maintaining a comfortable and healthy indoor environment.