Kenmore 153.33114, 153.33115 manual Installation Checklist

Page 11

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Sears at 1-800-4-MY-HOME (1-800-469-4663).

Installation Checklist

Water Heater Location

Water heater location is important and can affect system performance. Please check the following:

[] Installation area free of corrosive elements and flammable materials.

[] Centrally located with the water piping system (For new installations). Located as close to the gas piping and vent pipe system as possible.

[] Located indoors and in a vertical position. Protected from freezing temperatures.

[] Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

[] Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

[] Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

[] Water heater not located near an air moving device.

[] Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)? If so, the base-ring filter located on the bottom of the water heater will need to be cleaned

periodically. Refer to the "Maintenance of your Water Heater" section of this manual for information on cleaning the base-ring filter.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air for the combustion of gas wilt result in the flame becoming "lazy", thereby allowing heat to build up in the combustion chamber. This excessive heat wilt cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

[] Are there openings for make-up air to enter and exit the room/area?

[] Are the openings of sufficient size? Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the "Installation Instructions" and "Combustion Air Supply and Ventilation" sections for specific requirements.

[] Make sure that fresh air is not taken from areas that contain negative pressure producing devices such as exhaust fans, dryers, fireplaces, etc.

[] Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air- Conditioning & Refrigeration (HVAC-R) authorized service provider.

[] Use a fresh air supply that is free of corrosive elements and flammable vapors.

[] Fresh airopenings must be sized correctly with consideration given to the blocking effect of louvers and grilles.

[] Ductwork must be the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood. Refer to the "Checking the Draft" section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following:

[] Draft hood properly installed.

[] Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

[] Vent connector made of approved material and sized correctly.

[] Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the

"National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition.

[] Flue baffle properly positioned in the flue tube.

[] Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the "Combustion Air Supply and Ventilation" section of this water heater manual for specific requirements.

[] Recheck for sufficient combustion air supply.

Water System Piping

[] Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

[] All piping properly installed and free of leaks.

[] Heater completely filled with water.

[] Closed system pressure build-up devices installed.

[] Mixing valve (when applicable) installed per manufacturer's instructions (See "Water Temperature Regulation" section).

Gas Supply and Piping

[] Gas type is the same as that listed on the water heater rating plate.

[] Gas line equipped with shut-off valve, union, and drip leg.

[] Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.R)] gases.

[] Adequate pipe size and approved pipe material.

[] An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. If such a solution is not available, use a mixture of dish washing soap and water (one part soap to 15 parts water) or children's soap bubble solution. Bubbles forming indicate a leak. Correct any leak found.

11

Image 11
Contents 320391-000 Sears Brands Management CorporationModel No 153.331140 40 Gallon 153.331150 50 GallonImportant Definitions Read and follow water heater warnings and instructionsExplosion Hazard Improper installation and use may result in property damageFire or Explosion Hazard Fire Hazard12-15 InstallationVent Pipe System Draft Hood Installation Vent Connectors 19-20StartUpConditions OperatingtheTemperatureControlSystemService LightingInstructionsYear Limited Warranty on Water Heater Important Information About This Water Heater Excessive Weight HazardModel Materials Needed Status Mark Light Control/Temperature KnobTemperatures shown are approximates and may vary Vent Pipe Inner DoorInstallation Checklist Manual GAS Removing the Old Water HeaterFire or Explosion Hazard Location RequirementsSite Location Carbon Monoxide Poisoning HazardAll water heaters eventually leak Insulation BlanketsProperty Damage Hazard Breathing Hazard Carbon Monoxide GasProperty Damage Hazard Filling the Water HeaterGas Requirements Gas PipingExplosion Hazard Gas Pressure TestingGas Pressure LP Gas OnlyConfined Space Carbon Monoxide WarningUnconfined Space All Air from Inside the BuildingLouvers and Grilles All Air from OutdoorsVent Pipe System Draft Hood InstallationVent Connectors Vent Pipe SizeOpposite wall of the chimney Figure Chimney ConnectionVertical Exhaust Gas Vent Chimney as it may restrict the space between itLminimum Piping InstallationIsectn 19 MGL Closed System/Thermal Expansion Temperature and Pressure Relief ValveIf the Pilot Does Not Light Lighting InstructionsLighting the Pilot If the Status Light Does Not BlinkIgniterGASCONTROL STOP!It is imyou readall safety lightingthe pilotRefertothe UghtingInstructionsinthe Installation Phone. Follow the gas supptiersinstructionsEmergency Shut Down Water Temperature RegulationChecking the Draft Burner FlamesStatus Light Code Normal Flashes Operating the Temperature Control SystemFiue gases may escape if ,vent pipe is not connected Vent System InspectionBurner Inspection Carbon Monoxide and Fire HazardFire and Explosion Hazard HousekeepingAnode Rod Inspection Draining and FlushingService Removing the Burner from the Manifold Burner Assembly Replacement PartsExternal Inspection & Cleaning Base-Ring Filter Removing the Manifold/Burner AssemblyBurneran other Cleaning the Combustion Chamber and Flame-arrestorPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyExplosion Hazard Removing the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatStrange Sounds Thermal Ex ansion Tank SpecificationsExpansion Tank Sizing Chart Start Up ConditionsAIR In Hot Water Faucets Safety Shut-off and Thermal SwitchOperational Conditions CondensationBefore installing, operating or servicing this water heater Problem Thermostat Not functioning properly Replace Water heater flue or vent systemBlocked Excessive Waterpressure Use Pressure Reducing ValveNormal Operation Pilot light was recently extinguishedThermopile is cooling DownGas Control Valve failure Temperature Sensor Thermistor Is defectiveSection Pilot light Repeatedly Goes out =N01800-4694663 Model 153.331140 Gallon153.331150 Gallon Page MY-HOME

153.33114, 153.33115 specifications

The Kenmore 153.33115 and 153.33114 are high-efficiency dehumidifiers designed to effectively manage moisture levels in residential spaces, providing comfort and safeguarding homes against the damaging effects of excess humidity. Both models embody Kenmore's commitment to quality, innovative technologies, and user-friendly features, making them ideal choices for maintaining optimal indoor air quality.

One of the standout features of the Kenmore 153.33115 and 153.33114 is their powerful dehumidification capability. With the capacity to remove up to 70 pints of moisture per day, these dehumidifiers efficiently tackle dampness in areas of up to 1,500 square feet. This makes them suitable for various spaces, including basements, laundry rooms, and even larger living areas, ensuring a healthy environment free from mold and mildew growth.

The models are equipped with an adjustable humidistat, which allows users to set their desired humidity levels easily. This feature not only enhances user control but also ensures energy efficiency by allowing the machines to operate only when necessary. Alongside energy efficiency, these dehumidifiers are designed to comply with Department of Energy guidelines, making them an eco-friendly choice.

Both models also feature a continuous drainage option, enabling hassle-free operation without the need for constant manual emptying of the water tank. When the water tank reaches capacity, an automatic shut-off function prevents overflow, ensuring peace of mind for users.

In terms of convenience, the Kenmore 153.33115 and 153.33114 have a user-friendly digital control panel with an easy-to-read LED display. This intuitive interface makes it simple to adjust settings, check humidity levels, and monitor overall performance. Additionally, the inclusion of wheels and a lightweight design enhances portability, allowing users to move the dehumidifiers where they are needed most.

Another notable aspect is the enhanced air filtration system. These dehumidifiers come with a removable, washable filter that effectively captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

In conclusion, the Kenmore 153.33115 and 153.33114 are exemplary dehumidifiers that combine efficient moisture removal, user-friendly features, and eco-conscious designs. With their robust performance, effective humidity control, and added convenience features, these models stand out as reliable solutions for maintaining a comfortable and healthy indoor environment.