Kenmore 153.33114 manual Location Requirements, Site Location, Carbon Monoxide Poisoning Hazard

Page 13

Location Requirements

I Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Doing so can result in carbon monoxide poisoning and death.

The FVIR System is designed to reduce the risk of flammable vapor-related fires. The patented system protects your family by trapping the burning vapors within the water heater combustion chamber through the special flame-arrestor. The burning vapors literally "burn themselves out" without escaping back into the room. In the event of a flammable vapor incident, the FVIR System disables the water heater by shutting off the gas supply to the water heater's burner and pilot, preventing re-ignition of any remaining flammable vapors in the area. This will not prevent a possible fire/explosion if the igniter is depressed and flammable vapors have accumulated in the combustion chamber with the pilot light off. If you suspect a flammable vapor incident has occurred, do not use this appliance. Do not attempt to light this appliance, or depress the igniter button if you suspect flammable vapors have accumulated inside or outside the appliance. Immediately call a qualified technician to inspect the appliance. Water heaters subjected to a flammable vapors incident will show a discoloration on the flame-arrestor and require replacement of the entire water heater.

Rarnrnable Vapors

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

_Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other appliance. Storage of or use of gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

Do not use or store flammable products such as gasoline, solvents, or adhesives in the same room or area near the water heater. If such flammables must be used, all gas burning appliances in the vicinity must be shut off and their pilot lights extinguished. Open the doors and windows for ventilation while flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the

area of the water heater, leave the area immediately and call the fire department from a neighbor's home. Do not attempt to clean the spill until all ignition sources have been extinguished.

Fire or Explosion Hazard

Read instruction manual before installing, using or servicing water heater.

Improper use may result in fire or explosion.

Maintain required clearances to combustibles.

Keep combustibles such as boxes, magazines, clothes, etc. away from the water heater area.

Site Location

Select a location near the center of the water piping system. The water heater must be installed indoors and in a vertical

position on a level surface. DO NOT install in bathrooms, bedrooms, or any occupied room normally kept closed.

Locate the water heater as close to the chimney or gas vent as practical. Consider the vent system piping and combustion air supply requirements when selecting the water heater location. The venting system must be able to run from the water heater to termination with minimal length and elbows.

Locate the water heater near the existing gas piping. If installing a new gas line, locate the water heater to minimize the pipe length and elbows.

The water heater should be located in an area not subject to freezing temperatures. Water heaters located in unconditioned spaces (i.e., attics, basements, etc.) may require insulation of the water piping and drain piping to protect against freezing. The drain and controls must be easily accessible for operation and service. Maintain proper clearances as specified on the rating plate.

Do not locate the water heater near an air-moving device.

The operation of air-moving devices such as exhaust fans, ventilation systems, clothes dryers, fireplaces, etc., can affect the proper operation of the water heater. Special

attention must be given to conditions these devices may create. Flow reversal of flue gases may cause an increase of carbon monoxide inside of the dwelling (Figure 8).

If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to periodically clean the base-ring filter and flame-arrestor (see External Inspection & Cleaning of the Flame-arrestor).

This water heater is not for use in manufactured (mobile) homes or outdoor installation.

NOTE: This water heater must be installed according to all local and state codes or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223.1(NFPA 54)-current edition.

REVERSE FLOW

L OF GASES

FIGURE 8

13

Image 13
Contents Model No Sears Brands Management Corporation153.331140 40 Gallon 153.331150 50 Gallon 320391-000Important Definitions Read and follow water heater warnings and instructionsFire or Explosion Hazard Improper installation and use may result in property damageFire Hazard Explosion HazardVent Pipe System Draft Hood Installation InstallationVent Connectors 19-20 12-15Service OperatingtheTemperatureControlSystemLightingInstructions StartUpConditionsYear Limited Warranty on Water Heater Important Information About This Water Heater Excessive Weight HazardModel Materials Needed Temperatures shown are approximates and may vary Control/Temperature KnobVent Pipe Inner Door Status Mark LightInstallation Checklist Manual GAS Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Fire or Explosion HazardProperty Damage Hazard Insulation BlanketsBreathing Hazard Carbon Monoxide Gas All water heaters eventually leakGas Requirements Filling the Water HeaterGas Piping Property Damage HazardGas Pressure Gas Pressure TestingLP Gas Only Explosion HazardUnconfined Space Carbon Monoxide WarningAll Air from Inside the Building Confined SpaceLouvers and Grilles All Air from OutdoorsVent Connectors Draft Hood InstallationVent Pipe Size Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionChimney as it may restrict the space between it Opposite wall of the chimney FigureIsectn 19 MGL Piping InstallationLminimum Closed System/Thermal Expansion Temperature and Pressure Relief ValveLighting the Pilot Lighting InstructionsIf the Status Light Does Not Blink If the Pilot Does Not LightRefertothe UghtingInstructionsinthe Installation STOP!It is imyou readall safety lightingthe pilotPhone. Follow the gas supptiersinstructions IgniterGASCONTROLChecking the Draft Water Temperature RegulationBurner Flames Emergency Shut DownStatus Light Code Normal Flashes Operating the Temperature Control SystemBurner Inspection Vent System InspectionCarbon Monoxide and Fire Hazard Fiue gases may escape if ,vent pipe is not connectedAnode Rod Inspection HousekeepingDraining and Flushing Fire and Explosion HazardService External Inspection & Cleaning Base-Ring Filter Replacement PartsRemoving the Manifold/Burner Assembly Removing the Burner from the Manifold Burner AssemblyBurneran other Cleaning the Combustion Chamber and Flame-arrestorExplosion Hazard Replacing the Manifold/Burner AssemblyPiezoelectric Igniter System Removing the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatExpansion Tank Sizing Chart Thermal Ex ansion Tank SpecificationsStart Up Conditions Strange SoundsOperational Conditions Safety Shut-off and Thermal SwitchCondensation AIR In Hot Water FaucetsBefore installing, operating or servicing this water heater Problem Blocked Water heater flue or vent systemExcessive Waterpressure Use Pressure Reducing Valve Thermostat Not functioning properly ReplaceThermopile is cooling Pilot light was recently extinguishedDown Normal OperationGas Control Valve failure Temperature Sensor Thermistor Is defective800-4694663 =N01Section Pilot light Repeatedly Goes out 153.331150 Gallon 153.331140 GallonModel Page MY-HOME

153.33114, 153.33115 specifications

The Kenmore 153.33115 and 153.33114 are high-efficiency dehumidifiers designed to effectively manage moisture levels in residential spaces, providing comfort and safeguarding homes against the damaging effects of excess humidity. Both models embody Kenmore's commitment to quality, innovative technologies, and user-friendly features, making them ideal choices for maintaining optimal indoor air quality.

One of the standout features of the Kenmore 153.33115 and 153.33114 is their powerful dehumidification capability. With the capacity to remove up to 70 pints of moisture per day, these dehumidifiers efficiently tackle dampness in areas of up to 1,500 square feet. This makes them suitable for various spaces, including basements, laundry rooms, and even larger living areas, ensuring a healthy environment free from mold and mildew growth.

The models are equipped with an adjustable humidistat, which allows users to set their desired humidity levels easily. This feature not only enhances user control but also ensures energy efficiency by allowing the machines to operate only when necessary. Alongside energy efficiency, these dehumidifiers are designed to comply with Department of Energy guidelines, making them an eco-friendly choice.

Both models also feature a continuous drainage option, enabling hassle-free operation without the need for constant manual emptying of the water tank. When the water tank reaches capacity, an automatic shut-off function prevents overflow, ensuring peace of mind for users.

In terms of convenience, the Kenmore 153.33115 and 153.33114 have a user-friendly digital control panel with an easy-to-read LED display. This intuitive interface makes it simple to adjust settings, check humidity levels, and monitor overall performance. Additionally, the inclusion of wheels and a lightweight design enhances portability, allowing users to move the dehumidifiers where they are needed most.

Another notable aspect is the enhanced air filtration system. These dehumidifiers come with a removable, washable filter that effectively captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

In conclusion, the Kenmore 153.33115 and 153.33114 are exemplary dehumidifiers that combine efficient moisture removal, user-friendly features, and eco-conscious designs. With their robust performance, effective humidity control, and added convenience features, these models stand out as reliable solutions for maintaining a comfortable and healthy indoor environment.