Kenmore 153.33115, 153.33114 manual Chimney Connection, Vertical Exhaust Gas Vent

Page 20

inspection, and replacement.

Vent connectors cannot pass through any ceiling, floor, firewall, or fire partition.

It is recommended (but not mandatory) that a minimum 12 inches of vertical vent pipe be installed on the draft hood prior to any elbow in the vent system.

IMPORTANT: Existing vent systems must be inspected for obstructions, corrosion, and proper installation.

Chimney Connection

IMPORTANT: Before connecting a vent to a chimney, make sure the chimney passageway is clear and free of obstructions. The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces. Also consult local and state codes for proper chimney sizing and application or, in the absence of local and state codes, the "National Fuel Gas Code", ANSI Z223. I(NFPA 54)-current edition.

The connector

must

be installed above the extreme

bottom

 

of the chimney

to

prevent potentially blocking

the flue

 

gases.

 

 

 

(Figures 20 and 21).

IMPORTANT: This gas vent must be terminated in a vertical position to facilitate the removal of the burnt gases.

An unused chimney flue or masonry enclosure may be used as a passageway for the installation of a gas vent (Figure 21 ).

Common (combined) venting is allowable with vertical type B vent systems and lined masonry chimneys as tong as proper draft for the water heater is established under all conditions of operation. IMPORTANT: DO NOT common vent this water heater with any power vented appliance.

Figures 19-21 are examples of vent pipe system installations and may or may not be typical for your specific application. Consult the "National Fuel Gas Code", NFPA 54, ANSI Z223.1- current edition and the guidelines set forth by prevailing local codes.

2 FT. MINIMUM ABOVE ANY OBJECT

3 FT. MINtMU!WITHIN 10 FT. HORIZONTALLY

The

connector

must

be firmly

attached

and sealed

to

 

prevent it from falling out.

 

 

 

To aid in removing the connector,

a thimble

or slip joint may

 

be used.

 

 

 

 

 

The

connector

must

not extend

beyond the inner edge

of

SUPPORT

*MAINTAIN

CLEARANCE

t

TYPE B DOUBLE

WALLVENTPIPE

the chimney as it may restrict the space between it and the

opposite wall of the chimney (Figure 19).

LISTED LINED

CHIMNEY

2 FT. MINIMUM ABOVE ANY OBJECT

WITHIN 10FT. HORIZONTALLY

3FT-MINIMUM I

SUPPORT

STRAP

MAINTAIN

CLEARANCE*

DO NOT EXTEND

t

OF CHIMNEY

CONNECTOR

CHIMNEY TERMINATION VENT SYSTEM

FIGURE 19.

Do not terminate the vent connector in a chimney that has not been certified for this purpose. Some local codes may prohibit the termination of vent connectors in a masonry chimney.

Vertical Exhaust Gas Vent

Vertical exhaust gas vents must be installed with U.L. listed type B vent pipe according to the vent manufacturer's instructions and the terms of its listing.

It must be connected to the water heater's draft hood by a listed vent connector or by directly originating at the draft hood opening.

Vertical gas vents must terminate with a listed cap or other roof assembly and be installed according to their manufacturer's instructions.

Gas vents must be supported to prevent damage, joint separation, and maintain clearances to combustible materials

**MAINTAIN

CLEARANCE

VERTICAL GAS VENT SYSTEM WITH

TYPE B DOUBLE WALL VENT PIPE.

FIGURE 20.

 

 

 

±

-i_LISTED

VENT CAP

 

 

 

 

MAINTAIN

MANUFACTURER'S

 

 

 

 

SPECIFIED

MINIMUM CLEARANCE

T

 

 

_MAINTAIN

 

 

 

 

 

 

 

 

 

SPECIFIED

 

 

 

 

 

CLEARANCE

 

SUPPORT

 

 

 

 

 

STRAP

 

 

 

 

*MAINTAIN

 

 

 

 

CLEARANCE

 

 

 

 

 

 

t

 

 

 

 

 

VENT

 

 

 

CONNECTOR

CONNECTOR

 

 

UNUSED

CHIMNEY

SLOPE

 

 

 

 

 

 

 

I_IN.

PBR

FT.

 

_,--'-FLUE

OR

MASONRY

 

 

 

 

MINIMUM

ENCLOSURE

VENTING THROUGH A CHIMNEY WITH

TYPE B DOUBLE WALL VENT PIPE.

FIGURE 21.

,Maintain vent pipe clearance requirements to local, state and/or the "National Fuel Gas Code",ANSI Z223.1(NFPA 54)-current edition.

**NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Buming Appliances states that these chimneys are intended to be installed in accordance with the installation ins_uctions provided with each chimney support assembly. Minimum air space clearance to

combustible materials should be maintained as marked on the chimney sections.

2O

Image 20
Contents Sears Brands Management Corporation Model No153.331140 40 Gallon 153.331150 50 Gallon 320391-000Read and follow water heater warnings and instructions Important DefinitionsImproper installation and use may result in property damage Fire or Explosion HazardFire Hazard Explosion HazardInstallation Vent Pipe System Draft Hood InstallationVent Connectors 19-20 12-15OperatingtheTemperatureControlSystem ServiceLightingInstructions StartUpConditionsYear Limited Warranty on Water Heater Excessive Weight Hazard Important Information About This Water HeaterModel Materials Needed Control/Temperature Knob Temperatures shown are approximates and may varyVent Pipe Inner Door Status Mark LightInstallation Checklist Removing the Old Water Heater Manual GASLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard Fire or Explosion HazardInsulation Blankets Property Damage HazardBreathing Hazard Carbon Monoxide Gas All water heaters eventually leakFilling the Water Heater Gas RequirementsGas Piping Property Damage HazardGas Pressure Testing Gas PressureLP Gas Only Explosion HazardCarbon Monoxide Warning Unconfined SpaceAll Air from Inside the Building Confined SpaceAll Air from Outdoors Louvers and GrillesDraft Hood Installation Vent ConnectorsVent Pipe Size Vent Pipe SystemChimney Connection Vertical Exhaust Gas VentChimney as it may restrict the space between it Opposite wall of the chimney FigureLminimum Piping InstallationIsectn 19 MGL Temperature and Pressure Relief Valve Closed System/Thermal ExpansionLighting Instructions Lighting the PilotIf the Status Light Does Not Blink If the Pilot Does Not LightSTOP!It is imyou readall safety lightingthe pilot Refertothe UghtingInstructionsinthe InstallationPhone. Follow the gas supptiersinstructions IgniterGASCONTROLWater Temperature Regulation Checking the DraftBurner Flames Emergency Shut DownOperating the Temperature Control System Status Light Code Normal FlashesVent System Inspection Burner InspectionCarbon Monoxide and Fire Hazard Fiue gases may escape if ,vent pipe is not connectedHousekeeping Anode Rod InspectionDraining and Flushing Fire and Explosion HazardService Replacement Parts External Inspection & Cleaning Base-Ring FilterRemoving the Manifold/Burner Assembly Removing the Burner from the Manifold Burner AssemblyCleaning the Combustion Chamber and Flame-arrestor Burneran otherPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyExplosion Hazard Removing and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatThermal Ex ansion Tank Specifications Expansion Tank Sizing ChartStart Up Conditions Strange SoundsSafety Shut-off and Thermal Switch Operational ConditionsCondensation AIR In Hot Water FaucetsBefore installing, operating or servicing this water heater Problem Water heater flue or vent system BlockedExcessive Waterpressure Use Pressure Reducing Valve Thermostat Not functioning properly ReplacePilot light was recently extinguished Thermopile is coolingDown Normal OperationTemperature Sensor Thermistor Is defective Gas Control Valve failureSection Pilot light Repeatedly Goes out =N01800-4694663 Model 153.331140 Gallon153.331150 Gallon Page MY-HOME

153.33114, 153.33115 specifications

The Kenmore 153.33115 and 153.33114 are high-efficiency dehumidifiers designed to effectively manage moisture levels in residential spaces, providing comfort and safeguarding homes against the damaging effects of excess humidity. Both models embody Kenmore's commitment to quality, innovative technologies, and user-friendly features, making them ideal choices for maintaining optimal indoor air quality.

One of the standout features of the Kenmore 153.33115 and 153.33114 is their powerful dehumidification capability. With the capacity to remove up to 70 pints of moisture per day, these dehumidifiers efficiently tackle dampness in areas of up to 1,500 square feet. This makes them suitable for various spaces, including basements, laundry rooms, and even larger living areas, ensuring a healthy environment free from mold and mildew growth.

The models are equipped with an adjustable humidistat, which allows users to set their desired humidity levels easily. This feature not only enhances user control but also ensures energy efficiency by allowing the machines to operate only when necessary. Alongside energy efficiency, these dehumidifiers are designed to comply with Department of Energy guidelines, making them an eco-friendly choice.

Both models also feature a continuous drainage option, enabling hassle-free operation without the need for constant manual emptying of the water tank. When the water tank reaches capacity, an automatic shut-off function prevents overflow, ensuring peace of mind for users.

In terms of convenience, the Kenmore 153.33115 and 153.33114 have a user-friendly digital control panel with an easy-to-read LED display. This intuitive interface makes it simple to adjust settings, check humidity levels, and monitor overall performance. Additionally, the inclusion of wheels and a lightweight design enhances portability, allowing users to move the dehumidifiers where they are needed most.

Another notable aspect is the enhanced air filtration system. These dehumidifiers come with a removable, washable filter that effectively captures dust, allergens, and other airborne particles, contributing to better indoor air quality.

In conclusion, the Kenmore 153.33115 and 153.33114 are exemplary dehumidifiers that combine efficient moisture removal, user-friendly features, and eco-conscious designs. With their robust performance, effective humidity control, and added convenience features, these models stand out as reliable solutions for maintaining a comfortable and healthy indoor environment.