Heat & Glo LifeStyle SL-950TV-IPI-E Install the Mesh, Install Trim and/or Surround, Install Hood

Page 36

G. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 14.5).

Replacing Fixed Glass Assembly

Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame.

LATCHES (BOTH BOTTOM

AND TOP)

GLASS

ASSEMBLY

Figure 14.5 Fixed Glass Assembly

H. Install the Mesh

The screen mesh is a protective barrier and must be at- tached to the appliance front/door.

I. Install Trim and/or Surround

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model).

J. Install Hood

Hood is included with this appliance and required in all installations.

K. Air Shutter Setting

Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.6.

Loosen the wing nut.

Push the air handle in to close the air shutter.

Pull the air handle out to open the air shutter.

Tighten the wing nut.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

SHUTTER ADJUSTMENT

Figure 14.6 Air Shutter

Air Shutter Settings

Models

NG

LP

SL-550TV-IPI-E

Fully Closed

3/16 in.

SL-750TV-IPI-E

Fully Closed

3/16 in.

SL-950TV-IPI-E

3/16 in.

3/8 in.

36

Heat & Glo • SL-550 / 750 / 950TV-IPI-E2119-900 Rev. J • 12/09

Image 36
Contents SL-550TV-IPI-E SL-750TV-IPI-E SL-950TV-IPI-E What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingReference Materials Limited Lifetime Warranty Limited Lifetime Warranty Listing and Code Approvals Appliance CertificationTempered Glass Specifications BTU SpecificationsHigh Altitude Installations Non-Combustible Materials SpecificationCombustible Materials Specification Electrical CodesGas Fireplace Safety Operating Instructions User GuideYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Decorative Doors and FrontsLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsEither cobrahead or SIT Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Combustible MantelsTermination Locations Vent Termination Minimum ClearancesVent Information and Diagrams Vent GuidelinesVent System Configuration Vent Clearances and Framing Pipe Clearances to CombustiblesWall and Ceiling Penetration Framing Vertical Penetration FramingInstalling Outside Air Kit Damper Assem- bly Appliance PreparationGas and Electrical Connections Securing and Leveling the ApplianceInstalling Vent Pipe Assembly of Vent SectionsInstall Attic Insulation Shield Securing Vent SectionsGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Optional Accessories RequirementsElectrical Information Code CSA C22.1Ignition Module 3 VAC Transformer PLUG-IN Junction Box Installation Wall Switch Installation for Fan OptionalDimensions of Combustibles FinishingNoncombustible Facing Diagram Facing MaterialAppliance Setup Install the Log Assembly PIN Hole Install the Mesh Install Trim and/or SurroundInstall Hood Air Shutter SettingTroubleshooting Symptom Possible Cause Corrective ActionIntellifire Ignition System Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsService Parts List At DepotSL-750TV-IPI-E SL-750TV-IPI-E SL-950TV-IPI-E SL-950TV-IPI-E StockedIPI Valve Assembly SL-550 / 750 / 950TV-IPI-EContact Information