G. Fixed Glass Assembly
Removing Fixed Glass Assembly
WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.
•DO NOT strike, slam or scratch glass.
•DO NOT operate fireplace with glass removed, cracked, broken or scratched.
•Replace as a complete assembly.
Removing Fixed Glass Assembly
•Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 14.5).
Replacing Fixed Glass Assembly
•Replace the glass door on the appliance. Pull out and latch the four glass assembly latches into the groove on the glass frame.
LATCHES (BOTH BOTTOM
AND TOP)
GLASS
ASSEMBLY
Figure 14.5 Fixed Glass Assembly
H. Install the Mesh
The screen mesh is a protective barrier and must be at- tached to the appliance front/door.
I. Install Trim and/or Surround
•Install optional trim kits and/or surrounds using the instructions included with the accessory.
•Use
J. Install Hood
Hood is included with this appliance and required in all installations.
K. Air Shutter Setting
Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.6.
•Loosen the wing nut.
•Push the air handle in to close the air shutter.
•Pull the air handle out to open the air shutter.
•Tighten the wing nut.
NOTICE: If sooting occurs, provide more air by opening the air shutter.
SHUTTER ADJUSTMENT |
Figure 14.6 Air Shutter |
Air Shutter Settings
Models | NG | LP |
Fully Closed | 3/16 in. | |
Fully Closed | 3/16 in. | |
| 3/16 in. | 3/8 in. |
36 | Heat & Glo • |