Heat & Glo LifeStyle SL-550TV-IPI-E, SL-950TV-IPI-E, SL-750TV-IPI-E Ues to spark, and main

Page 38

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

 

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

4. Pilot lights but contin-

sensing rod.

connections underneath pilot assembly are tight. Verify con-

ues to spark, and main

 

nections are not grounding out to metal chassis, pilot burn-

burner will not ignite.

 

er, pilot enclosure or screen if present, or any other metal

(If the pilot continues

 

object.

to spark after the

 

 

B. Poor flame rectification or contaminated

With fixed glass assembly in place, verify that flame is en-

pilot flame has been lit,

flame sensing rod.

gulfing flame sensing rod on left side of pilot hood. Flame

flame rectification has

 

sensing rod should glow shortly after ignition. Verify cor-

not occurred.)

 

 

rect pilot orifice is installed and gas inlet is set to pressure

 

 

 

 

specifications. Clean flame sensing rod with emery cloth to

 

 

remove any contaminants that may have accumulated on

 

 

flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

pliance. Verify that wire harness is firmly connected to the

 

 

module.

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the flame sensing rod

 

nated flame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

flame sensing rod to white sensor wire. Clean flame sensing

 

 

rod with emery cloth to remove any contaminants that may

 

 

have accumulated on flame sensing rod. Verify continuity

 

 

with a multimeter with ohms set at lowest range. Replace

 

 

pilot if any damage is detected.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position.

 

 

Remove ignitor wire “I” from module. Place ON/OFF rocker

 

 

switch or wall switch in ON position. If there is no spark at “I”

 

 

terminal module must be replaced. If there is a spark at “I”

 

 

terminal, module is fine.

 

 

 

38

Heat & Glo • SL-550 / 750 / 950TV-IPI-E2119-900 Rev. J • 12/09

Image 38
Contents SL-550TV-IPI-E SL-750TV-IPI-E SL-950TV-IPI-E What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideReference Materials Appliance SetupTroubleshooting Limited Lifetime Warranty Limited Lifetime Warranty Tempered Glass Specifications Listing and Code ApprovalsAppliance Certification BTU SpecificationsCombustible Materials Specification High Altitude InstallationsNon-Combustible Materials Specification Electrical CodesYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors and FrontsLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsEither cobrahead or SIT Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Negative Pressure Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Combustible MantelsTermination Locations Vent Termination Minimum ClearancesVent System Configuration Vent Information and DiagramsVent Guidelines Wall and Ceiling Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Vertical Penetration FramingGas and Electrical Connections Installing Outside Air Kit Damper Assem- blyAppliance Preparation Securing and Leveling the ApplianceInstall Attic Insulation Shield Installing Vent PipeAssembly of Vent Sections Securing Vent SectionsGas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Information Wiring RequirementsOptional Accessories Requirements Code CSA C22.1Ignition Module 3 VAC Transformer PLUG-IN Junction Box Installation Wall Switch Installation for Fan OptionalDimensions of Combustibles FinishingNoncombustible Facing Diagram Facing MaterialAppliance Setup Install the Log Assembly PIN Hole Install Hood Install the MeshInstall Trim and/or Surround Air Shutter SettingIntellifire Ignition System TroubleshootingSymptom Possible Cause Corrective Action Ues to spark, and main Appliance Dimension Diagram Reference MaterialsLog Set Assembly Service PartsService Parts List At DepotSL-750TV-IPI-E SL-750TV-IPI-E SL-950TV-IPI-E SL-950TV-IPI-E StockedIPI Valve Assembly SL-550 / 750 / 950TV-IPI-EContact Information