1 Listing and Code Approvals
A. Appliance Certification
MODELS: SL-550TV-IPI-E, SL-750TV-IPI-E, SL-950TV-IPI-E
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE:
STANDARD: ANSI
This product is listed to ANSI standards for “Vented Gas Fireplaces” and “Gas Fired Appliances for Use at High Altitudes”.
May be installed in a sleeping room when the provisions for combustion, ventilation and dilution air are met per the requirements of ANSI 223.1/NFPA 54 National Fuel Gas Code. In Canada, installation in a sleeping room requires installation with a thermostat certified for use with this prod- uct. Consult your local authorities having jurisdiction.
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI
This model (natural gas and propane) can be installed in a bedroom (in Canada) if a thermostat (Model
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.
B. Tempered Glass Specifications
Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as defined by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been tested and certified to the requirements of ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certification Council SGCC# 1595 and 1597. Architectur- al Testing, Inc. Reports
This statement is in compliance with CPSC 16 CFR Sec- tion 1201.5 “Certification and labeling requirements” which refers to 15 U.S. Code (USC) 2063 stating “…Such certificate shall accompany the product or shall otherwise be furnished to any distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please contact your dealer or distributor to order.
C. BTU Specifications
Model(s) | Maximum | Minimum | Orifice | ||
U.S. | Input BTU/h | Input BTU/h | Size | ||
(DMS) | |||||
US | 21,100 | 14,700 | 44 | ||
|
|
|
| ||
CAN | 18,990 | 13,230 | 45 | ||
| |||||
|
|
|
|
| |
US | 20,000 | 14,300 | 55 | ||
|
|
|
| ||
CAN | 18,000 | 12,870 | 56 | ||
| |||||
|
|
|
|
| |
US | 24,800 | 17,700 | 42 | ||
|
|
|
| ||
CAN | 22,320 | 15,930 | 43 | ||
| |||||
|
|
|
|
| |
US | 23,200 | 17,300 | 54 | ||
|
|
|
| ||
CAN | 20,880 | 15,570 | 55 | ||
| |||||
|
|
|
|
| |
US | 30,900 | 21,300 | 37 | ||
|
|
|
| ||
CAN | 27,810 | 19,170 | 38 | ||
| |||||
|
|
|
|
| |
US | 30,700 | 22,500 | 52 | ||
|
|
|
| ||
CAN | 27,630 | 20,250 | 53 | ||
| |||||
|
|
|
|
|