Step 4

Step 4

Positioning,

Leveling, and

Securing the

Fireplace

1.Place the fireplace into position.

2.Level the fireplace from side to side and from front to back.

3.Shim the fireplace with non-combus- tible material, such as sheet metal, as necessary.

4.Secure the fireplace to the framing by nailing or screwing

Step 5

The Gas Control

Systems

The diagram below shows how to properly position, level, and secure the fireplace.

Figure 27. Proper Positioning, Leveling, and

Securing of a Fireplace

WARNING

THIS UNIT IS NOT FOR USE WITH

SOLID FUEL.

Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI). Model 6000XLT has Standing Pilot Ignition only. Model 6000ARCH has DSI only.

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING

110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System

This system includes a 24V control valve, electronic module, transformer, and spark ignitor/flame sensor.

WARNING

110-120 VAC MUST BE WIRED TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.

WARNING

DIRECT VENT PROPANE MODELS WITH DSI CONTROL SYSTEMS CANNOT BE USED IN CANADA.

28

Image 31
Contents 8000 DVTFL Underwriters Laboratories ListedInstallers Guide Heat-N-GloFireplaceTHIS UNIT IS NOT FOR USE WITH SOLID FUEL SAFETY AND WARNING INFORMATIONPROHIBITED Table of Contents High Altitude Installations Approvals and Codesand Codes Installation CodesANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD Pre-installationPreparationIntroducing the Heat-N-Glo Gas Fireplaces Getting StartedFigure 1. Diagram of 8000DVTFL Page Figure 3. Diagram of SL-42DVT Step Locating the Fireplace Installing the FireplaceClearance Requirements CONSTRUCTION BEGINS Step Framing the FireplaceVERIFY FRAMING METHODS AND WALL COVERING DETAILS, BEFORE FRAMINGA. Vent System Approvals Step Installing the Vent SystemDV-12D DV-90DDV-45D DV-48D DV-36D4-inchinner pipe/6 5/8-inchouter pipe VERTICAL VENTING V FT 40 MAX. 12.4 M Figure 9. Vertical VentingNOTE MODEL 6000 ARCH ATTACHED TO THE UNIT, THE Model 6000XLT & 8000DVTFLFOR SL-42DVT NOTE: IF A 90 ELBOW IS FIRSTH1 V H VENTING WITH TWO 2 90 ELBOWSFigure 11. Venting with two 90 elbows NOTE MODEL 6000 ARCHH V1 V VENTING WITH TWO 2 90 ELBOWSFigure 12. Venting with two 90 elbows NOTE: MODEL 6000 ARCHFigure 13. Venting with three 90 elbows VENTING WITH THREE 3 90 ELBOWSNOTE: MODEL 6000 ARCH Figure 14. Venting with three 90 elbows VENTING WITH THREE 3 90 ELBOWSB. Installing Vent Components ENSURE THAT THE FIBERGLASS •Place the pipe supports around the vent pipe 3. Install Support BracketsTo install support brackets for horizontal runs Figure 17. Adding Venting ComponentsModel DVK-01TRDand SLK-01TRDdo not need Figure 18. Installing Support Brackets4. Install Firestops For Horizontal Runs - Firestops are REQUIREDFigure 19. Hole and Vent Pipe Figure 22. Ceiling Firestop Ceiling Side Figure 21. Hole and New Framing MembersFigure 23. Attic Firestop C. Vent TerminationFigure 24. Round and Trapezoid Termination Caps TERMINATION CAPS VINYL SIDING, IT IS NECESSARY TO INSTALLIF EXTERIOR WALLS ARE FINISHED WITH THE VINYL PROTECTOR KIT TO THE TOP OFon the outside of the building MAJOR U.S. BUILDING CODESRoof Pitch Fireplace Step Positioning Leveling, and Securing theStep The Gas Control Systems DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS Step The Gas Supply LineFigure 28. Gas Controls Systems 13 mm hook-upat the unitNatural Gas Step Gas Pressure RequirementsFigure 29. Gas Supply Line PressureFor Standing Pilot Ignition Wiring Step Wiring the FireplaceERRORS CAN CAUSE IMPROPER AND Electrical wiring must be installed by a licensedLABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRINGStep Finishing Hearth Extensions Step Installing Trim Logs, and Ember MaterialSave the log instructions with this manual Positioning the LogsPlacing the Ember Material Figure 36. Placement of the Ember Material Figure 35. Glass Assembly1.Lift the trim door up and out of the unit Double-checkfor faulty components Lighting the Fireplace After the InstallationStep Before Lighting the Fireplace Step Review safety warnings and cautionsYOUR FIREPLACE Fireplace MaintenanceMaintaining and Servicing Your Fireplace TURN OFF THE GAS BEFORE SERVICINGFigure 38. Pilot/Ignitor Flame Patterns Figure 37. Burner Flame PatternsPART DESCRIPTION Replacement Parts and AccessoriesStanding Pilot Only PARTPART DESCRIPTION DSI Ignition Only8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT PARTBoth Standing Pilot and DSI Ignition PART AccessoriesBoth Standing Pilot and DSI Ignition Cont ACCESSORY