Heat & Glo LifeStyle 6000 DVTFL DSI Ignition Only, 8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT, Part

Page 44
DSI Ignition Only

41

DSI Ignition Only

(8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT)

PART

PART DESCRIPTION

PART NUMBER

 

DSI Valve LP

SRV77–501

 

DSI Valve NG

SRV77–500

 

Transformer

SRV60–599

 

DSI Module

SRV420–592

 

Electrode

SRV77–591

 

Burner Tube

 

 

- 8000DVTFL

SRV410–303

 

- 6000DVTFL, 6000ARCH

SRV422–302

 

- SL-42DVT

SRV486-302

Image 44
Contents Underwriters Laboratories Listed Installers GuideHeat-N-GloFireplace 8000 DVTFLPROHIBITED SAFETY AND WARNING INFORMATIONTHIS UNIT IS NOT FOR USE WITH SOLID FUEL Table of Contents Approvals and Codes and CodesInstallation Codes High Altitude InstallationsPre-installationPreparation Introducing the Heat-N-Glo Gas FireplacesGetting Started ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARDFigure 1. Diagram of 8000DVTFL Page Figure 3. Diagram of SL-42DVT Clearance Requirements Installing the FireplaceStep Locating the Fireplace Step Framing the Fireplace VERIFY FRAMING METHODS AND WALLCOVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINSStep Installing the Vent System A. Vent System ApprovalsDV-90D DV-45DDV-48D DV-36D DV-12D4-inchinner pipe/6 5/8-inchouter pipe NOTE MODEL 6000 ARCH Figure 9. Vertical VentingVERTICAL VENTING V FT 40 MAX. 12.4 M Model 6000XLT & 8000DVTFL FOR SL-42DVTNOTE: IF A 90 ELBOW IS FIRST ATTACHED TO THE UNIT, THEVENTING WITH TWO 2 90 ELBOWS Figure 11. Venting with two 90 elbowsNOTE MODEL 6000 ARCH H1 V HVENTING WITH TWO 2 90 ELBOWS Figure 12. Venting with two 90 elbowsNOTE: MODEL 6000 ARCH H V1 VNOTE: MODEL 6000 ARCH VENTING WITH THREE 3 90 ELBOWSFigure 13. Venting with three 90 elbows VENTING WITH THREE 3 90 ELBOWS Figure 14. Venting with three 90 elbowsB. Installing Vent Components ENSURE THAT THE FIBERGLASS 3. Install Support Brackets To install support brackets for horizontal runsFigure 17. Adding Venting Components •Place the pipe supports around the vent pipeFigure 18. Installing Support Brackets 4. Install FirestopsFor Horizontal Runs - Firestops are REQUIRED Model DVK-01TRDand SLK-01TRDdo not needFigure 19. Hole and Vent Pipe Figure 21. Hole and New Framing Members Figure 22. Ceiling Firestop Ceiling SideC. Vent Termination Figure 23. Attic FirestopFigure 24. Round and Trapezoid Termination Caps VINYL SIDING, IT IS NECESSARY TO INSTALL IF EXTERIOR WALLS ARE FINISHED WITHTHE VINYL PROTECTOR KIT TO THE TOP OF TERMINATION CAPSMAJOR U.S. BUILDING CODES on the outside of the buildingRoof Pitch Step The Gas Control Systems Step Positioning Leveling, and Securing theFireplace Step The Gas Supply Line Figure 28. Gas Controls Systems13 mm hook-upat the unit DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKSStep Gas Pressure Requirements Figure 29. Gas Supply LinePressure Natural GasStep Wiring the Fireplace For Standing Pilot Ignition WiringElectrical wiring must be installed by a licensed LABEL ALL WIRES PRIOR TO DISCONNECTIONWHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER ANDStep Finishing Step Installing Trim Logs, and Ember Material Hearth ExtensionsPlacing the Ember Material Positioning the LogsSave the log instructions with this manual 1.Lift the trim door up and out of the unit Figure 35. Glass AssemblyFigure 36. Placement of the Ember Material Lighting the Fireplace After the Installation Step Before Lighting the Fireplace StepReview safety warnings and cautions Double-checkfor faulty componentsFireplace Maintenance Maintaining and Servicing Your FireplaceTURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACEFigure 37. Burner Flame Patterns Figure 38. Pilot/Ignitor Flame PatternsReplacement Parts and Accessories Standing Pilot OnlyPART PART DESCRIPTIONDSI Ignition Only 8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVTPART PART DESCRIPTIONBoth Standing Pilot and DSI Ignition Accessories Both Standing Pilot and DSI Ignition ContACCESSORY PART