Heat & Glo LifeStyle SL-42 DVT manual Both Standing Pilot and DSI Ignition Cont, Accessories, Part

Page 46
Both Standing Pilot and DSI Ignition (Cont.)

43

Both Standing Pilot and DSI Ignition (Cont.)

PART

PART DESCRIPTION

PART NUMBER

 

Trim Door

 

 

- 8000DVTFL

DF–8000

 

- 6000 MODELS (MESH)

DF-6000

 

- 6000 MODELS (NO MESH)

DF-36

 

- SL-42DVT

DF-8000-BK

 

Log Set Assembly

 

 

- 8000DVTFL

LOGS-8FL

 

- 6000DVTFL

LOGS-6FL

 

- 6000XLT

LOGS-CAMP

 

- SL-42DVT

LOGS-SL42

 

Bottom Right Refractory

SRV486-370

 

SL-42DVT

 

 

 

Bottom Left Refractory

SRV486-371

 

SL-42DVT

 

 

 

Grate Assembly SL-42DVT

SRV486-360A

Accessories

 

 

 

ACCESSORY

PART DESCRIPTION

PART NUMBER

 

Fan Kit

GFK-160A

 

 

 

GFK-270

 

 

Remote Control Kit

RCH-09A

 

 

 

RC-SMART

 

 

SMART-STAT

 

 

RC-MLT

 

 

Wall Switch Kit

 

 

 

- Off White

WSK-21

 

 

- White

WSK-21-W

 

 

Trim Door Mesh (SL-42DVT)

MESH-42

 

 

 

Nat. Gas

LPG

 

Refractory (SL-42DVT)

MET-REF-42

Image 46
Contents Heat-N-GloFireplace Underwriters Laboratories ListedInstallers Guide 8000 DVTFLTHIS UNIT IS NOT FOR USE WITH SOLID FUEL SAFETY AND WARNING INFORMATIONPROHIBITED Table of Contents Installation Codes Approvals and Codesand Codes High Altitude InstallationsGetting Started Pre-installationPreparationIntroducing the Heat-N-Glo Gas Fireplaces ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARDFigure 1. Diagram of 8000DVTFL Page Figure 3. Diagram of SL-42DVT Step Locating the Fireplace Installing the FireplaceClearance Requirements COVERING DETAILS, BEFORE FRAMING Step Framing the FireplaceVERIFY FRAMING METHODS AND WALL CONSTRUCTION BEGINSStep Installing the Vent System A. Vent System ApprovalsDV-48D DV-36D DV-90DDV-45D DV-12D4-inchinner pipe/6 5/8-inchouter pipe VERTICAL VENTING V FT 40 MAX. 12.4 M Figure 9. Vertical VentingNOTE MODEL 6000 ARCH NOTE: IF A 90 ELBOW IS FIRST Model 6000XLT & 8000DVTFLFOR SL-42DVT ATTACHED TO THE UNIT, THENOTE MODEL 6000 ARCH VENTING WITH TWO 2 90 ELBOWSFigure 11. Venting with two 90 elbows H1 V HNOTE: MODEL 6000 ARCH VENTING WITH TWO 2 90 ELBOWSFigure 12. Venting with two 90 elbows H V1 VFigure 13. Venting with three 90 elbows VENTING WITH THREE 3 90 ELBOWSNOTE: MODEL 6000 ARCH VENTING WITH THREE 3 90 ELBOWS Figure 14. Venting with three 90 elbowsB. Installing Vent Components ENSURE THAT THE FIBERGLASS Figure 17. Adding Venting Components 3. Install Support BracketsTo install support brackets for horizontal runs •Place the pipe supports around the vent pipeFor Horizontal Runs - Firestops are REQUIRED Figure 18. Installing Support Brackets4. Install Firestops Model DVK-01TRDand SLK-01TRDdo not needFigure 19. Hole and Vent Pipe Figure 21. Hole and New Framing Members Figure 22. Ceiling Firestop Ceiling SideC. Vent Termination Figure 23. Attic FirestopFigure 24. Round and Trapezoid Termination Caps THE VINYL PROTECTOR KIT TO THE TOP OF VINYL SIDING, IT IS NECESSARY TO INSTALLIF EXTERIOR WALLS ARE FINISHED WITH TERMINATION CAPSMAJOR U.S. BUILDING CODES on the outside of the buildingRoof Pitch Fireplace Step Positioning Leveling, and Securing theStep The Gas Control Systems 13 mm hook-upat the unit Step The Gas Supply LineFigure 28. Gas Controls Systems DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKSPressure Step Gas Pressure RequirementsFigure 29. Gas Supply Line Natural GasStep Wiring the Fireplace For Standing Pilot Ignition WiringWHEN SERVICING CONTROLS. WIRING Electrical wiring must be installed by a licensedLABEL ALL WIRES PRIOR TO DISCONNECTION ERRORS CAN CAUSE IMPROPER ANDStep Finishing Step Installing Trim Logs, and Ember Material Hearth ExtensionsSave the log instructions with this manual Positioning the LogsPlacing the Ember Material Figure 36. Placement of the Ember Material Figure 35. Glass Assembly1.Lift the trim door up and out of the unit Review safety warnings and cautions Lighting the Fireplace After the InstallationStep Before Lighting the Fireplace Step Double-checkfor faulty componentsTURN OFF THE GAS BEFORE SERVICING Fireplace MaintenanceMaintaining and Servicing Your Fireplace YOUR FIREPLACEFigure 37. Burner Flame Patterns Figure 38. Pilot/Ignitor Flame PatternsPART Replacement Parts and AccessoriesStanding Pilot Only PART DESCRIPTIONPART DSI Ignition Only8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT PART DESCRIPTIONBoth Standing Pilot and DSI Ignition ACCESSORY AccessoriesBoth Standing Pilot and DSI Ignition Cont PART