Heat & Glo LifeStyle 6000 XLT manual Step Gas Pressure Requirements, Gas Supply Line, Natural Gas

Page 33
Step 7

The gas line should be installed by a qualified service technician.

Step 7

Gas Pressure

Requirements

At the gas line access hole, use insulation to re- pack the space around the gas pipe.

Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal be- tween the pipe and the outer casing.

Figure 29. Gas Supply Line

Pressure requirements for Heat-N-Glo gas fireplaces are shown in the table below.

Pressure

Natural Gas

Propane

 

 

 

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

 

 

 

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

 

 

 

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

 

 

 

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is provided on the outlet side of the gas control for a test gauge connection to measure the manifold pressure. To measure inlet pressure, provisions must be made to attach a test gauge to a one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping immediately upstream of the gas supply connection to the fireplace.

The fireplace and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of one-half (1/2) psig (3.5 kPa).

The fireplace must be isolated from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than one- half (1/2) psig (3.5 kPa).

30

Image 33
Contents Installers Guide Underwriters Laboratories ListedHeat-N-GloFireplace 8000 DVTFLSAFETY AND WARNING INFORMATION THIS UNIT IS NOT FOR USE WITH SOLID FUELPROHIBITED Table of Contents and Codes Approvals and CodesInstallation Codes High Altitude InstallationsIntroducing the Heat-N-Glo Gas Fireplaces Pre-installationPreparationGetting Started ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARDFigure 1. Diagram of 8000DVTFL Page Figure 3. Diagram of SL-42DVT Installing the Fireplace Step Locating the FireplaceClearance Requirements VERIFY FRAMING METHODS AND WALL Step Framing the FireplaceCOVERING DETAILS, BEFORE FRAMING CONSTRUCTION BEGINSA. Vent System Approvals Step Installing the Vent SystemDV-45D DV-90DDV-48D DV-36D DV-12D4-inchinner pipe/6 5/8-inchouter pipe Figure 9. Vertical Venting VERTICAL VENTING V FT 40 MAX. 12.4 MNOTE MODEL 6000 ARCH FOR SL-42DVT Model 6000XLT & 8000DVTFLNOTE: IF A 90 ELBOW IS FIRST ATTACHED TO THE UNIT, THEFigure 11. Venting with two 90 elbows VENTING WITH TWO 2 90 ELBOWSNOTE MODEL 6000 ARCH H1 V HFigure 12. Venting with two 90 elbows VENTING WITH TWO 2 90 ELBOWSNOTE: MODEL 6000 ARCH H V1 VVENTING WITH THREE 3 90 ELBOWS Figure 13. Venting with three 90 elbowsNOTE: MODEL 6000 ARCH Figure 14. Venting with three 90 elbows VENTING WITH THREE 3 90 ELBOWSB. Installing Vent Components ENSURE THAT THE FIBERGLASS To install support brackets for horizontal runs 3. Install Support BracketsFigure 17. Adding Venting Components •Place the pipe supports around the vent pipe4. Install Firestops Figure 18. Installing Support BracketsFor Horizontal Runs - Firestops are REQUIRED Model DVK-01TRDand SLK-01TRDdo not needFigure 19. Hole and Vent Pipe Figure 22. Ceiling Firestop Ceiling Side Figure 21. Hole and New Framing MembersFigure 23. Attic Firestop C. Vent TerminationFigure 24. Round and Trapezoid Termination Caps IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS NECESSARY TO INSTALLTHE VINYL PROTECTOR KIT TO THE TOP OF TERMINATION CAPSon the outside of the building MAJOR U.S. BUILDING CODESRoof Pitch Step Positioning Leveling, and Securing the FireplaceStep The Gas Control Systems Figure 28. Gas Controls Systems Step The Gas Supply Line13 mm hook-upat the unit DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKSFigure 29. Gas Supply Line Step Gas Pressure RequirementsPressure Natural GasFor Standing Pilot Ignition Wiring Step Wiring the FireplaceLABEL ALL WIRES PRIOR TO DISCONNECTION Electrical wiring must be installed by a licensedWHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER ANDStep Finishing Hearth Extensions Step Installing Trim Logs, and Ember MaterialPositioning the Logs Save the log instructions with this manualPlacing the Ember Material Figure 35. Glass Assembly Figure 36. Placement of the Ember Material1.Lift the trim door up and out of the unit Step Before Lighting the Fireplace Step Lighting the Fireplace After the InstallationReview safety warnings and cautions Double-checkfor faulty componentsMaintaining and Servicing Your Fireplace Fireplace MaintenanceTURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACEFigure 38. Pilot/Ignitor Flame Patterns Figure 37. Burner Flame PatternsStanding Pilot Only Replacement Parts and AccessoriesPART PART DESCRIPTION8000DVTFL, 6000DVTFL, 6000ARCH, SL-42DVT DSI Ignition OnlyPART PART DESCRIPTIONBoth Standing Pilot and DSI Ignition Both Standing Pilot and DSI Ignition Cont AccessoriesACCESSORY PART