This display window shows that for Monday’s occupied heating period, the start time is 8:00 AM, 70° is the programmed temperature, and the fan is set to PRG FAN (continuous fan operation); this ex- ample reflects factory preprogramming, where 70° is the HEAT O temperature.
3.To change the displayed start time to your selected start time for Monday’s occupied
heating period, press TIMEFWD or BACKTIME until your
selected time appears. The time will change in 15 minute increments.
4.If the temperature displayed is not the HEAT O temperature you want for Monday’s occupied heating period, press
or (if you continue to press
or , the display will alternate
between the HEAT O and HEAT U tem- peratures you previously selected).
NOTE
Damper operation is linked to the occupied or unoccupied temperature selections, not to the occupied or unoccupied time periods. The damper will be open only during periods with occupied temperatures. Therefore, we sug- gest that you program occupied temperatures during occupied periods and unoccupied tem- peratures during unoccupied periods.
5.If you want the fan to run continuously during Monday’s occupied heating period,
press | FAN | until PRG FAN is displayed. |
SWITCH |
25