Desa TSTEA-A Venting Installation Instructions, Installation Precautions, Installation Planning

Page 11

Venting Installation

Instructions

WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.

WARNING: Seal all connec- tions with high temperature silicone every time a vent con- nection is made. Before joining elbows or pipes, apply a bead of high temperature silicone sealant to the male end of the elbow or pipe. High temperature silicone must also be used to re- seal any connections after main- tenance to venting system.

NOTICE:Failuretofollowthesein- structions will void the warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance.

Installation Precautions

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.

Only a qualified service person should install venting system. The installer must follow these safety rules:

Wear gloves and safety glasses for protection

Use extreme caution when using ladders or when on roof tops

Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:

Installation of any damaged venting component

Unauthorized modification of the venting system

Installation of any component part not manu- factured or approved by DESA

Installation other than as instructed by these instructions

WARNING: This gas fireplace and vent assembly must be venteddirectlytotheoutside.The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appli- ance. Each gas appliance must use a separate vent system. Do not use common vent systems.

WARNING: Horizontal sec- tions of this vent system require a minimum clearance of 2" from the top of the pipe and 1" mini- mum to the sides and bottom. Vertical sections of this system require a minimum of 1" clear- ance to combustible materials on all sides of the pipe.

INSTALLATION PLANNING

There are two basic types of direct-vent installation:

Horizontal Termination

Vertical Termination

It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.

For Horizontal Termination: Select the amount of vertical rise desired. The horizontal run of venting must have 1/4" rise for every 12" of run towards the termination.

WARNING: Never run the vent downward as this may cause excessive temperatures which could cause a fire.

You may use one or two 90° elbows in this vent configuration. See Horizontal Termination Con- figurations on page 15.

56131-F

www.desatech.com

11

Image 11
Contents Peninsula Model Shown Peninsula Models VDVF36Safety Information Table of ContentsSafety Information High traffic areas Right Side Front View DimensionsMantel Clearances Pre-Installation PreparationLocation and space requirements ClearancesFraming Rough Opening for Installing Vent Termination Clearances General VentingMinimum Clearances for Vent Terminations Installation Planning Venting Installation InstructionsInstallation Precautions Snorkel Installation for horizontal terminationInstalling Vent System in a Chase Snorkel 90º Minimum 12 Minimum 45ºVent Cap Wood Screw Male Slots Female Locking Lugs Rigid Vent PipeConnecting Vent Cap with Horizontal Vent Pipe Horizontal Venting Installation for vertical TerminationVenting with Two 90 Elbows Min. Height from Roof Flat Ceiling InstallationLowest Listed Discharge Vent Cap Opening Minimum Gas ClearanceCathedral Ceiling Support Box Installation Cathedral Ceiling InstallationVertical V Horizontal H Min Max 20 max Starter Elbow Vertical V Horizontal H 1 +Min Max 20 max Starter Elbow Venting with One 90 ElbowDesa 5/8 Pipe & Vent Kits Number Description High altitude installationParts list for Desa venting kits and components Vertical VentingScrews Dura Vent 5/8 Pipe & Vent Kits Number Description01492 Electrical Hookup for optional blower accessory InstallationWall Switch Installation To Thermopoile Optional Wireless hand-held Remote Control InstallationFor Optional Fan Kit From Blower Assembly Red WhiteGAS Line HOOK-UP Installing Log Set Gas Supply TestingLeft Back Front Right Open CloseBurner Removal Pilot/Electrode Assembly AdjustmentBurner Flame Adjustment Decorative FacingLogs Operating Guidlines Maintenance InstructionsLouver Assembly Glass Door Hearth PanOperating Fireplace Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Glass Assembly Frame Retainer Screws Louver AssemblyGas Control Knob Position Indicator Flame Adjustment KnobLighting Instructions To Turn OFF GAS To ApplianceParts Under Warranty SpecificationsService Hints Technical ServiceMillivolt system TroubleshootingParts Not Under Warranty Problem Possible Cause RemedyElectronic ignition system TroubleshootingGAS Valve Wiring DiagramsReceiver and HAND-HELD Pilot AssemblySkytech Remote Control KIT High Voltage Cable Replacement Parts AccessoriesLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty