Desa TSTPEA-A, (V)DVF36 Specifications, Service Hints, Technical Service, Parts Under Warranty

Page 30

OPERATING FIREPLACE

Continued

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information beginning on page 29, column 1, before proceeding.

2.Set thermostat to lowest setting (if appli- cable).

3.Turn off wall switch.

4.Open control access panel or louver.

5.Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step.

6.The electrode is located by the main burner.

7.Turn main burner wall switch to the ON position for ignition. There will be a spark at the electrode.

8.Replace control access panel or louver once there is a flame at the burner.

If burner will not stay lit after several tries, flip wall switch to OFF and call your service technician or gas supplier.

Specifications

Models (V)DVF36TPNA-(A), (V)DVF36TPNPEA-(A), (V)DVF36TSTA-(A)

AND (V)DVF36TSTEA-(A)

• Input Rating: 35,000/23,300 Btu/Hr

• Fuel: Natural Gas

• Manifold Pressure: 3.5" W.C.

• Minimum Supply Pressure: 4.5 W.C. **

• Maximum Supply Pressure: 10.5" W.C.

• Orifice Size (0-4500 ft.): #34 DMS

Models (V)DVF36TPNPA-(A), (V)DVF36TPNPEA-(A), (V)DVF36TSTP-(A)

AND (V)DVF36TSTPEA-(A)

• Input Rating: 31,000/20,000 Btu/Hr

• Fuel: Propane/LP Gas

• Manifold Pressure: 10.0" W.C.

• Minimum Supply Pressure: 11.0 W.C. **

• Maximum Supply Pressure: 13.0" W.C.

• Orifice Size (0-4500 ft.): #51 DMS **For purpose of input adjustment.

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA’s

From Gas

 

 

Supply

 

 

 

 

L

 

 

O

 

E

A

Inlet

Outlet

Pressure

 

Pressure

I H

O

 

PIL T

To

 

 

Main

 

Burner

Flame

Adjustment

Knob

Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers ready.

You can also visit DESA’s Technical Services web site at www.desatech.com.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Figure 61 - Electronic Control Valve

Figure 62 - Electrode

TO TURN OFF GAS

TO APPLIANCE

1.Turn off all electrical power to appliance if service is to be performed.

2.Remove control access panel or louver.

3.Close gas valve.

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement part(s) call DESA’s Technical Service Department at 1-866-672-6040 for referral information.

When calling DESA, have ready

• your name • your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the factory.

30

www.desatech.com

56131-F

Image 30
Contents Peninsula Models VDVF36 Peninsula Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Right Side Front ViewClearances Pre-Installation PreparationLocation and space requirements Mantel ClearancesFraming Rough Opening for Installing General Venting Vent Termination ClearancesMinimum Clearances for Vent Terminations Venting Installation Instructions Installation PrecautionsInstallation Planning Snorkel 90º Minimum 12 Minimum 45º Installation for horizontal terminationInstalling Vent System in a Chase SnorkelMale Slots Female Locking Lugs Rigid Vent Pipe Vent Cap Wood ScrewConnecting Vent Cap with Horizontal Vent Pipe Installation for vertical Termination Venting with Two 90 ElbowsHorizontal Venting Clearance Flat Ceiling InstallationLowest Listed Discharge Vent Cap Opening Minimum Gas Min. Height from RoofCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVenting with One 90 Elbow Vertical V Horizontal H 1 +Min Max 20 max Starter Elbow Vertical V Horizontal H Min Max 20 max Starter ElbowVertical Venting High altitude installationParts list for Desa venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionDura Vent 5/8 Pipe & Vent Kits Number Description 01492Screws Installation Wall Switch InstallationElectrical Hookup for optional blower accessory Red White Optional Wireless hand-held Remote Control InstallationFor Optional Fan Kit From Blower Assembly To ThermopoileGAS Line HOOK-UP Gas Supply Testing Installing Log SetOpen Close Left Back Front RightDecorative Facing Pilot/Electrode Assembly AdjustmentBurner Flame Adjustment Burner RemovalGlass Door Hearth Pan Operating Guidlines Maintenance InstructionsLouver Assembly LogsGlass Assembly Frame Retainer Screws Louver Assembly Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Position Indicator Flame Adjustment KnobLighting Instructions Gas Control KnobTechnical Service SpecificationsService Hints Parts Under WarrantyProblem Possible Cause Remedy TroubleshootingParts Not Under Warranty Millivolt systemTroubleshooting Electronic ignition systemWiring Diagrams GAS ValvePilot Assembly Skytech Remote Control KITReceiver and HAND-HELD Replacement Parts Accessories High Voltage CableWarranty Information Keep this WarrantyLimited Warranty DIRECT-VENT Fireplace