Desa TSTPA-A, (V)DVF36 Operating Fireplace, Cleaning and Replacing Glass Door, Hinge Screws

Page 28

OPERATING GUIDELINES

AND MAINTENANCE

INSTRUCTIONS

Continued

Cleaning and Replacing Glass Door

Note: Before proceeding, make sure unit is com- pletely cool.

1.Remove top and bottom louvers and screen assembly. Undo 4 latches and open glass door. The procedure is the same for the end lover panel but the entire frame must be removed as one assembly.

2.To clean glass door, DO NOT remove glass from frame. Use any glass cleaner to clean glass. Do not use abrasive cleaners as this may damage glass.

3.If replacement is necessary, the entire assem- bly (frame and glass) must be replaced. If glass is broken, wear gloves and tape remaining fragments onto the frame. Remove 5 screws located on end of firebox while holding frame assembly to prevent it from falling and caus- ing injury (see Figure 57). Mount new frame at hinge with 5 new screws. Close and latch door. This will seat the gasket. If replacing end glass panel, remove 16 screws around frame

(see Figure 58) To insure proper fit, when installing new glass panels make sure seam in gasket is placed in the down position.

4.Replace screen assembly and top and bottom louvers.

Hinge

Screws

Figure 57 - Removing Glass Door

Glass

Assembly

Frame

Assembly

Retainer Screws

Louver Assembly

Figure 58 - End Panel Replacement

Operating Fireplace

Millivolt

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

28

www.desatech.com

56131-F

Image 28
Contents Peninsula Models VDVF36 Peninsula Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Right Side Front ViewPre-Installation Preparation Location and space requirementsClearances Mantel ClearancesFraming Rough Opening for Installing General Venting Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Precautions Venting Installation InstructionsInstallation Planning Installation for horizontal termination Installing Vent System in a ChaseSnorkel 90º Minimum 12 Minimum 45º SnorkelMale Slots Female Locking Lugs Rigid Vent Pipe Vent Cap Wood ScrewConnecting Vent Cap with Horizontal Vent Pipe Venting with Two 90 Elbows Installation for vertical TerminationHorizontal Venting Flat Ceiling Installation Lowest Listed Discharge Vent Cap Opening Minimum GasClearance Min. Height from RoofCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVertical V Horizontal H 1 + Min Max 20 max Starter ElbowVenting with One 90 Elbow Vertical V Horizontal H Min Max 20 max Starter ElbowHigh altitude installation Parts list for Desa venting kits and componentsVertical Venting Desa 5/8 Pipe & Vent Kits Number Description01492 Dura Vent 5/8 Pipe & Vent Kits Number DescriptionScrews Wall Switch Installation InstallationElectrical Hookup for optional blower accessory Optional Wireless hand-held Remote Control Installation For Optional Fan Kit From Blower AssemblyRed White To ThermopoileGAS Line HOOK-UP Gas Supply Testing Installing Log SetOpen Close Left Back Front RightPilot/Electrode Assembly Adjustment Burner Flame AdjustmentDecorative Facing Burner RemovalOperating Guidlines Maintenance Instructions Louver AssemblyGlass Door Hearth Pan LogsCleaning and Replacing Glass Door For Your Safety Read Before LightingGlass Assembly Frame Retainer Screws Louver Assembly Operating FireplacePosition Indicator Flame Adjustment Knob Lighting InstructionsTo Turn OFF GAS To Appliance Gas Control KnobSpecifications Service HintsTechnical Service Parts Under WarrantyTroubleshooting Parts Not Under WarrantyProblem Possible Cause Remedy Millivolt systemTroubleshooting Electronic ignition systemWiring Diagrams GAS ValveSkytech Remote Control KIT Pilot AssemblyReceiver and HAND-HELD Replacement Parts Accessories High Voltage CableKeep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace