Venting Installation
Instructions
Continued
Vertical Termination Configurations Figures 29 through 32 show four different configu- rations for vertical termination. These minimum vertical rises are based on horizontal runs with a minimum of 1/4" upwards pitch per foot ad do not reflect constraints on a vertical system with 45° or greater offset.
Any offset pitch of 45° or less must be considered horizontal and sized within the maximum allow- able lengths listed in the following examples. All connections must be sealed with high temperature silicone sealant as specified in the second warning statement on page 11.
Venting with Two 90° Elbows
Vertical (V) Horizontal (H1) + | |
| Horizontal (H2) |
5' min. | 2' max. |
6' min. | 4' max. |
7' min. | 6' max. |
8' min. | 8' max. |
20' max. | 8' max. |
45° Starter Elbow
Venting with One 90° Elbow
Vertical (V) Horizontal (H)
5' min. | 2' max. |
6' min. | 4' max. |
7' min. | 6' max. |
8' min. | 8' max. |
20' max. | 8' max. |
45° Starter Elbow
Note: Install restrictor into inner collar of fireplace as shown.
Figure 30 - Vertical Rigid Venting
Configuration Using One 90° Elbow
Note: Install restrictor into inner collar of fireplace as shown.
Figure 29 - Vertical Rigid Venting
Configuration Using Two 90° Elbows
with Two Horizontal Runs
Note: Install restrictor into inner collar of fireplace as shown.
45° Starter
Elbow
Venting with Two 90° Elbows
Vertical (V1) | Horizontal (H) |
5' min. | 6' max. |
6' min. | 12' max. |
7' min. | 18' max. |
8' min. | 20' max. |
Figure 31 - Vertical Rigid Venting
Configuration Using Two 90° Elbows