Desa TPNEA-A, (V)DVF36, TSTPA-A, TSTEA-A, TSTPEA-A Troubleshooting, Electronic ignition system

Page 32

TROUBLESHOOTING

Continued

PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, 1. Defective ignitor there is no spark at pilot

2. Defective pilot or misaligned electrode at pilot

3. No or low gas pressure

1.Replace ignitor if wire is prop- erly connected and you have no spark

2.Using a match, light pilot. If pi- lot lights turn off pilot and push piezo again. If pilot lights, an improper gas/air mixture cause improper lighting and a longer purge period is recommended. If pilot will not light, check gap at electrode and pilot. Gap should be 1/8" for strong spark. If elec- trode is okay, replace pilot

3.LP only: Check fuel supply and contact local propane/LP supplier if low.

LP and Natural: Check for kinked or bent hoses. Consult pipe fitter or plumber.

Electronic ignition system

 

 

 

PROBLEM

POSSIBLE CAUSE

REMEDY

Ignitor will not spark or burner

1. No or low gas pressure

1.

LP only: Check fuel supply

 

will not light

 

 

 

and contact local propane/LP

 

 

 

 

supplier if low.

 

 

 

 

LP and Natural: Check for

 

 

 

 

kinked or bent hoses. Consult

 

2.

Air in gas line

2.

pipe fitter or plumber.

 

Repeat lighting procedure

 

 

 

 

several times to purge air from

 

 

 

 

lines. If unit will still not light,

 

 

 

 

contact a qualified service and

 

3.

Construction debris clogging

3.

repair technician

 

Remove debris and dirt, in-

 

 

main orifice

 

spect and clean other possible

 

4.

Control valve knob not

4.

obstructions

 

Replace control valve

 

5.

opening

5.

Contact a qualified technician

 

Kinked pilot line

 

6.

No power to unit or ignition

6.

to replace pilot line

 

Check that main power is on

 

 

module/power transformer is

 

and all wire connections are

 

 

bad

 

made correctly to ignition

 

 

 

 

module

 

Burner will not stay lit

1. Loose wiring on ignition

1.

Check ignition wire connec-

 

 

module

 

tion - see Wiring Diagrams,

 

2. Poor ground to ignition

2.

page 33

 

Check ground wire connection

 

 

module

3.

- see Wiring Diagrams, page 33

 

3. Main burner flame too low

Clean and adjust main burner;

 

 

to sense

 

check gas supply and inlet

 

 

 

 

pressure; replace ignition as-

 

 

 

 

sembly if necessary

32

www.desatech.com

56131-F

Image 32
Contents Peninsula Models VDVF36 Peninsula Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Right Side Front ViewPre-Installation Preparation Location and space requirementsClearances Mantel ClearancesFraming Rough Opening for Installing General Venting Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Planning Venting Installation InstructionsInstallation Precautions Installation for horizontal termination Installing Vent System in a ChaseSnorkel 90º Minimum 12 Minimum 45º SnorkelMale Slots Female Locking Lugs Rigid Vent Pipe Vent Cap Wood ScrewConnecting Vent Cap with Horizontal Vent Pipe Horizontal Venting Installation for vertical TerminationVenting with Two 90 Elbows Flat Ceiling Installation Lowest Listed Discharge Vent Cap Opening Minimum GasClearance Min. Height from RoofCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVertical V Horizontal H 1 + Min Max 20 max Starter ElbowVenting with One 90 Elbow Vertical V Horizontal H Min Max 20 max Starter ElbowHigh altitude installation Parts list for Desa venting kits and componentsVertical Venting Desa 5/8 Pipe & Vent Kits Number DescriptionScrews Dura Vent 5/8 Pipe & Vent Kits Number Description01492 Electrical Hookup for optional blower accessory InstallationWall Switch Installation Optional Wireless hand-held Remote Control Installation For Optional Fan Kit From Blower AssemblyRed White To ThermopoileGAS Line HOOK-UP Gas Supply Testing Installing Log SetOpen Close Left Back Front RightPilot/Electrode Assembly Adjustment Burner Flame AdjustmentDecorative Facing Burner RemovalOperating Guidlines Maintenance Instructions Louver AssemblyGlass Door Hearth Pan LogsCleaning and Replacing Glass Door For Your Safety Read Before LightingGlass Assembly Frame Retainer Screws Louver Assembly Operating FireplacePosition Indicator Flame Adjustment Knob Lighting InstructionsTo Turn OFF GAS To Appliance Gas Control KnobSpecifications Service HintsTechnical Service Parts Under WarrantyTroubleshooting Parts Not Under WarrantyProblem Possible Cause Remedy Millivolt systemTroubleshooting Electronic ignition systemWiring Diagrams GAS ValveReceiver and HAND-HELD Pilot AssemblySkytech Remote Control KIT Replacement Parts Accessories High Voltage CableLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty