Desa TPNA-A(-HA) Pilot/Electrode Assembly Adjustment, Burner Flame Adjustment, Decorative Facing

Page 26

Installation

Continued

DECORATIVE FACING

Any noncombustible material may be used for facing (glass, tile, brick, etc.) as long as the proper clearances are observed (see Clearances, page 6). IMPORTANT: Louvered openings must not be ob- structed, and upper and lower panels must remain removable for servicing. Use only heat-resistant, noncombustible mortar or adhesive when securing facing material.

Note: Combustible material, such as wood, that has been fireproofed is not considered noncom- bustible.

Pilot/Electrode

Assembly Adjustment

The pilot assembly is factory preset for the proper flame height. Alteration to these settings may have occurred during shipping and handling. If this is the case, some minor adjustment may be necessary and should be done by a qualified technician. To access the pilot assembly, the glass door must be opened. The proper settings for the thermopile height should be at a distance of 3/8" to 1/2" from the pilot flame as shown in Figure 52.

The electrode is installed at the factory for proper positioning. However, alterations to the position may have occurred due to shipping and handling. These settings may need adjustment and must be done by a qualified technician. The correct position and height is as shown in Figure 53.

1/8"

 

(0.3cm)

3/8" - 1/2"

 

 

(.95cm-1.3cm)

Figure 52 - Correct Pilot Flame Pattern

3/4"

(19 mm)

1/2"

(12.7 mm)

Edge of Burner

Top of

Burner

 

Figure 53 - Correct Ignitor Location

(Side View)

Burner Flame

Adjustment

The air shutter, located at the base of the main burner (see Figure 54), has been factory preset to the proper air-to-gas ratio which results in an even, clean burning flame across the burner (see Figure 55). If readjustment is necessary, you can restore the proper air-to-gas ratio by loosening the air shutter screw and rotating the air shutter until the proper flame setting is achieved (the shutter's normal setting is fully open. Do not forget to retighten the air shutter screw.

 

Air

Air Shutter

Opening Adjustment Burner

Orifice

Screw

 

 

Venturi

 

 

Tube

Firebox Bottom

Burner Gas Line

 

Figure 54 - Air Shutter Adjustment

CORRECT

 

Long, Blue Flame with

 

 

 

 

Yellow Tips

INCORRECT

 

 

CLOSE

 

 

SHUTTER

Short, Sharp, Blowing Flame

 

INCORRECT

OPEN SHUTTER

Long, Uneven, Yellow Flame

Figure 55 - Burner Flame Patterns

Burner Removal

CAUTION: Before proceed- ing to open glass door or handle logs, make sure the entire unit is cool.

1.Remove top and bottom louvers and screen as- sembly. Undo 4 latches and open glass door.

2.Carefully remove the log set intact and set aside (see Figure 56, page 27).

3.Remove the 2 screws holding burner to hearth pan.

26

www.desatech.com

56131-F

Image 26
Contents Peninsula Models VDVF36 Peninsula Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Right Side Front ViewClearances Pre-Installation PreparationLocation and space requirements Mantel ClearancesFraming Rough Opening for Installing General Venting Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Planning Venting Installation InstructionsInstallation Precautions Snorkel 90º Minimum 12 Minimum 45º Installation for horizontal terminationInstalling Vent System in a Chase SnorkelMale Slots Female Locking Lugs Rigid Vent Pipe Vent Cap Wood ScrewConnecting Vent Cap with Horizontal Vent Pipe Horizontal Venting Installation for vertical TerminationVenting with Two 90 Elbows Clearance Flat Ceiling InstallationLowest Listed Discharge Vent Cap Opening Minimum Gas Min. Height from RoofCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVenting with One 90 Elbow Vertical V Horizontal H 1 +Min Max 20 max Starter Elbow Vertical V Horizontal H Min Max 20 max Starter ElbowVertical Venting High altitude installationParts list for Desa venting kits and components Desa 5/8 Pipe & Vent Kits Number DescriptionScrews Dura Vent 5/8 Pipe & Vent Kits Number Description01492 Electrical Hookup for optional blower accessory InstallationWall Switch Installation Red White Optional Wireless hand-held Remote Control InstallationFor Optional Fan Kit From Blower Assembly To ThermopoileGAS Line HOOK-UP Gas Supply Testing Installing Log SetOpen Close Left Back Front RightDecorative Facing Pilot/Electrode Assembly AdjustmentBurner Flame Adjustment Burner RemovalGlass Door Hearth Pan Operating Guidlines Maintenance InstructionsLouver Assembly LogsGlass Assembly Frame Retainer Screws Louver Assembly Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Position Indicator Flame Adjustment KnobLighting Instructions Gas Control KnobTechnical Service SpecificationsService Hints Parts Under WarrantyProblem Possible Cause Remedy TroubleshootingParts Not Under Warranty Millivolt systemTroubleshooting Electronic ignition systemWiring Diagrams GAS ValveReceiver and HAND-HELD Pilot AssemblySkytech Remote Control KIT Replacement Parts Accessories High Voltage CableLimited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty