Desa TPNPEA-A Optional Wireless hand-held Remote Control Installation, Red White, To Thermopoile

Page 22

Installation

Continued

You may test the blower for operation by turning the control knob clockwise just until it clicks on which is the full on position. Adjust the fan speed to the lowest setting (this should be no more than 1/4 of a turn clockwise).

For Optional

Fan Kit

From Blower

Assembly

Figure 37 - Connecting Blower

Accessory to Power Supply

OPTIONAL Wireless hand-held REMOTE CONTROL Installation

Note: If using an optional wireless hand-held remote control, the wall switch is no longer operational.

NOTICE: Only use alkaline bat- teries (not included).

Installing HRC100 Model Remote Control (Millivolt Models Only)

1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 21).

2.Disconnect wall switch wires from termi- nals marked TH and TPTH (see Figure 35, page 21).

3.Slide 9-volt battery into clip on back of remote receiver and connect battery terminals to bat- tery. Mount receiver onto bracket with clips provided (see Figure 38).

Plastic Mounting Clips

9-Volt Battery

Gas Receiver Clip

Valve Terminal

Wires

 

 

LOT

 

ON

 

16AI

 

OT

 

7

TH

L

 

I

 

 

 

P

 

 

 

FFO

L

HI

TP

 

O

E

A

 

TPTH

 

 

Red

White

FRONT

To Thermopoile

 

Figure 38 - Installing Remote Receiver

(HRC100)

4.Connect white wire to control valve terminal TH and red wire to TPTH. Move remote select switch to REMOTE position.

5.Replace louvered access panel by following reverse steps on page 21.

6.Remove battery cover on back of hand-held remote (see Figure 39). Remove and discard sensor tag.

7.Attach terminal wires to 9-volt batter. Place battery into housing.

8.Replace battery cover onto hand-held remote.

9.Set selector switch on receiver to OFF posi- tion if you will be away from the unit for an extended period of time.

Battery

Remote Control Unit

Cover

Sensor

 

 

Tag

Terminal

Wires

Battery

Housing

9-Volt Battery

Figure 39 - Installing Battery in Hand-

Held Remote Control Unit (HRC100)

Installing Skytech/WRC Model Remote Control (Electronic Models Only)

1.Remove lower louver access panel in fire- place (see step 1 of Wall Switch Installation, page 21).

2.If a wall switch was installed, it must be removed from ignition control circuit for remote to work properly. Remove wire nuts from switch connection at ignition control module. Using wire nut, connect transformer (blue) wire to remaining wire connected to control terminal marked P.SW (see Figure 34, page 21).

3.The receiver does not require a battery. To in- stall, plug extension cord into one of the outlet receptacles on the outlet box. Plug receiver unit into extension cord and the ignition module into receiver unit (see Figure 40, page 23).

4.Replace louvered access panel by following reverse steps on page 21.

5.Activate handset battery by removing insulat- ing tab on back (see Figure 41, page 23).

22

www.desatech.com

56131-F

Image 22
Contents Peninsula Models VDVF36 Peninsula Model ShownTable of Contents Safety InformationSafety Information High traffic areas Dimensions Right Side Front ViewClearances Pre-Installation PreparationLocation and space requirements Mantel ClearancesFraming Rough Opening for Installing General Venting Vent Termination ClearancesMinimum Clearances for Vent Terminations Installation Precautions Venting Installation InstructionsInstallation Planning Snorkel 90º Minimum 12 Minimum 45º Installation for horizontal terminationInstalling Vent System in a Chase SnorkelMale Slots Female Locking Lugs Rigid Vent Pipe Vent Cap Wood ScrewConnecting Vent Cap with Horizontal Vent Pipe Venting with Two 90 Elbows Installation for vertical TerminationHorizontal Venting Clearance Flat Ceiling InstallationLowest Listed Discharge Vent Cap Opening Minimum Gas Min. Height from RoofCathedral Ceiling Installation Cathedral Ceiling Support Box InstallationVenting with One 90 Elbow Vertical V Horizontal H 1 +Min Max 20 max Starter Elbow Vertical V Horizontal H Min Max 20 max Starter ElbowVertical Venting High altitude installationParts list for Desa venting kits and components Desa 5/8 Pipe & Vent Kits Number Description01492 Dura Vent 5/8 Pipe & Vent Kits Number DescriptionScrews Wall Switch Installation InstallationElectrical Hookup for optional blower accessory Red White Optional Wireless hand-held Remote Control InstallationFor Optional Fan Kit From Blower Assembly To ThermopoileGAS Line HOOK-UP Gas Supply Testing Installing Log SetOpen Close Left Back Front RightDecorative Facing Pilot/Electrode Assembly AdjustmentBurner Flame Adjustment Burner RemovalGlass Door Hearth Pan Operating Guidlines Maintenance InstructionsLouver Assembly LogsGlass Assembly Frame Retainer Screws Louver Assembly Cleaning and Replacing Glass DoorFor Your Safety Read Before Lighting Operating FireplaceTo Turn OFF GAS To Appliance Position Indicator Flame Adjustment KnobLighting Instructions Gas Control KnobTechnical Service SpecificationsService Hints Parts Under WarrantyProblem Possible Cause Remedy TroubleshootingParts Not Under Warranty Millivolt systemTroubleshooting Electronic ignition systemWiring Diagrams GAS ValveSkytech Remote Control KIT Pilot AssemblyReceiver and HAND-HELD Replacement Parts Accessories High Voltage CableKeep this Warranty Warranty InformationLimited Warranty DIRECT-VENT Fireplace