Desa EFS26NRA, EFS26PRA, VMH26PRB, VMH26NRB Optional Wall Mounted, Thermostat GWMT1

Page 20

INSTALLATION

OPTIONAL WALL MOUNTED

Continued

THERMOSTAT - GWMT1

 

Remote Receiver

 

Red Wire

Black Wire

 

Wire Harness*

 

Wires from

Red

Valve

Wire

 

Black

Wire

Figure 29 - Installing Remote Receiver

*Wire harness provided in the fireplace hard- ware pack.

Installing 9-Volt Battery in Hand-Held Remote Control Unit

1.Remove battery cover on back of remote con- trol unit.

2.Attach terminal wires to the battery (not in- cluded). Place battery into the battery housing.

3.Replace battery cover onto remote control unit.

Terminal

Battery Cover

 

Wires

 

9-Volt

 

Battery

 

 

Remote

 

Control

 

Battery Unit

 

Housing

Figure 30 - Installing Battery in Hand-Held

Remote Control Unit (GHRCB Series)

Terminal

9-Volt Wires

Battery

WARNING: Read and follow installation instructions. Instal- lation should be done by a quali- fied installer familiar with low- voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 32).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the positions on your unit as pictured in Figure 32. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace, or heat and air con- ditioning ducts.

4.Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base.

5.Feed the electrical wires through the rectan- gular slots on each side of the base (see Fig- ure 33, page 22).

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Switch on Gas

Control

Fireplace

Valve

 

 

Remote

AUTO

 

 

Control

OFF

 

 

ON

 

Battery

Unit

One terminal

 

Housing

Battery Cover

To Wall Thermostat

 

of 25 ft. wire

Figure 321- Installing Battery in Hand-Held

 

or Switch

Figure 32 - Connecting Wire Terminals

Remote Control Unit (GHRCTB Series)

20

www.desatech.com

113110-01A

Image 20
Contents Shown with optional cabinet mantel/hearth base accessory REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRATable of Contents Safety Information Product Identification Provide adequate clearances around air openingsOptional Remote Control Accessories Product FeaturesAssembly Local CodesUnusually Tight Construction Assembly AIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items BUILT-IN Fireplace Installation Fireplace ClearancesMinimum Clearance to Combustible Materials Minimum 16 inches from Side WallRough Opening for Installing Wall Optional Mantel Installation Mantel Clearances for Built-In InstallationAssemblingTrimTrimshippedwithmantel Installing Optional Blower Accessory GA3450TRemoving Upper Louver Assembly and Branch Support Installing Blower Accessory Extension Cord For Built-In InstallationTest to make sure the blower is working properly Connecting to GAS Supply External Regulator With Vent Pointing DownPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Correct all leaks at once Pressure Testing gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing ReceiverWire harness provided in the fireplace hard- ware pack Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove battery cover on back of remote con- trol unit Optional Wall MountedInstall the base onto the wall with the pro- vided screws Optional Wall Switch GWMS2Installing LOG SET and Screen For Your Safety Read Before Lighting Selector Switch OFF Position Control KnobIgnitor Button Flame Adjustment Knob Operating FireplaceManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off FireplaceON/OFF Series Model Ghrcb Thermostat Series Model GhrctbGWMS2 Wall Mounted Switch Optional Inspecting BurnersGWMT1 Wall Mounted Thermostat Optional Operating Blower OptionalBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Wiring Diagram LOG SETCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyReplace pilot assembly Ignitor cable drySafety interlock system has Low gas pressure ODS/pilot assemblyOr improperly connected Diagram, PressedBris. If found, clean burner Residues from manufacturTial operation Hours of operationGas leak. See Warning Specifications Remote-Ready ModelsReplacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List REMOTE-READY ModelsAccessories Equipment Shutoff Valve GA5010Perimeter Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbCabinet Mantel and Full Hearth Base Information VideoPage Page Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty InformationKeep this Warranty