Desa EFS26PRA Optional Remote Control Accessories, Local Codes, Product Features, Unpacking

Page 5

OPTIONAL REMOTE

CONTROL ACCESSORIES

There are four optional remote controls that can be purchased separately:

wall switch

hand-held ON/OFF remote

wall thermostat

hand-held thermostat remote See Accessories, pages 36 and 37.

LOCAL CODES

Install and use fireplace with care. Follow all lo- cal codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

SAFETY PILOT

This fireplace has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system re- quires no matches, batteries, or other sources to light fireplace.

UNPACKING

1.Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not re- move at this time.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hard- ware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, promptly inform dealer where you bought fireplace.

ASSEMBLY

WARNING: Always have branch support and screen in place before operating fireplace. This prevents excessive tem- peratures on fireplace surfaces.

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury.

ASSEMBLING FIREPLACE

Tools Required:

Phillips screwdriver

5/16" hex wrench

slotted screwdriver

scissors

1.Remove two screws that hold fireplace screen in place for shipping. These screws are located near top of screen. Discard screws. Lift fireplace screen up and pull out to remove. Set screen aside until installation has been completed.

2.Cut two plastic straps to remove the log from the firebox cavity.

3.An optional blower is available. See Acces- sories, pages 36 and 37. Install optional blower now. Follow installation instructions provided with blower or (see page 14).

Shoulder

Screw

Burner Support

With Log

Locator Tabs

Screen

Branch

Support

Figure 2 - Removing Screen

113110-01A

www.desatech.com

5

Image 5
Contents REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRA Shown with optional cabinet mantel/hearth base accessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationProduct Features Optional Remote Control AccessoriesAssembly Local CodesUnusually Tight Construction Assembly AIR for Combustion VentilationProviding Adequate Ventilation Determining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Fireplace Clearances BUILT-IN Fireplace InstallationMinimum Clearance to Combustible Materials Minimum 16 inches from Side WallRough Opening for Installing Wall Mantel Clearances for Built-In Installation Optional Mantel InstallationAssemblingTrimTrimshippedwithmantel Installing Optional Blower Accessory GA3450TRemoving Upper Louver Assembly and Branch Support Installing Blower Accessory Extension Cord For Built-In InstallationTest to make sure the blower is working properly External Regulator With Vent Pointing Down Connecting to GAS SupplyPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Correct all leaks at once Pressure Testing gas Supply Piping SystemChecking GAS Connections Installing Receiver Pressure Testing Fireplace Gas ConnectionsInstalling 9-Volt Battery in Hand-Held Remote Control Unit Wire harness provided in the fireplace hard- ware packRemove battery cover on back of remote con- trol unit Optional Wall MountedInstall the base onto the wall with the pro- vided screws Optional Wall Switch GWMS2Installing LOG SET and Screen Selector Switch OFF Position Control Knob For Your Safety Read Before LightingIgnitor Button Flame Adjustment Knob Operating FireplaceTo Turn OFF GAS To Appliance Manual Lighting ProcedureOptional HAND-HELD Remote Operation Shutting Off FireplaceThermostat Series Model Ghrctb ON/OFF Series Model GhrcbInspecting Burners GWMS2 Wall Mounted Switch OptionalGWMT1 Wall Mounted Thermostat Optional Operating Blower OptionalBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern LOG SET Wiring DiagramCabinet Air PassagewaysObserved Problem Possible Cause Remedy TroubleshootingReplace pilot assembly Ignitor cable dryLow gas pressure ODS/pilot assembly Safety interlock system hasOr improperly connected Diagram, PressedResidues from manufactur Bris. If found, clean burnerTial operation Hours of operationGas leak. See Warning Remote-Ready Models SpecificationsService Hints Replacement PartsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown REMOTE-READY Models Parts ListEquipment Shutoff Valve GA5010 AccessoriesPerimeter Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TReceiver and HAND-HELD Remote Control KIT Ghrcb Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbCabinet Mantel and Full Hearth Base Information VideoPage Page Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty InformationKeep this Warranty