Desa VMH26NRB, EFS26NRA, EFS26PRA, VMH26PRB installation manual Parts List, REMOTE-READY Models

Page 35

PARTS LIST

REMOTE-READY MODELS

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual.

 

PART NUMBERS

 

 

 

KEY

VMH26PRB

VMH26NRB

 

 

 

NO.

EFS26PRA

EFS26NRA

 

DESCRIPTION

QTY.

1

102633-02

102633-02

 

Outer Casing Top

1

2

102624-02

102624-02

 

Outer Casing

1

3

099230-02

099230-02

 

Shoulder Screw

14

4

098304-01

098304-01

 

Screw, #10 x 3/8"

13

5

109824-05

109824-05

 

Burner

1

6

098304-02

098304-06

 

Screw, PPH AB 6-20 x .38

4

7

102635-02

102635-02

 

Left and Right Side Front

2

8

103209-05

103209-05

 

Louver

2

9

104281-02CK

104281-02CK

 

Firebox Hood

1

10

102638-01

102638-01

 

Firebox Top

1

11

103778-01

103779-01

 

ODS/Pilot Assembly

1

12

**

**

 

Firebox Wrapper

1

13

104322-01

104322-01

 

Burner Tube

1

14

104335-01CK

104335-01CK

 

Outer Shell Base

1

15

102649-02

102649-02

 

Branch Support

1

16

102445-01

102445-01

 

Piezo Ignitor

1

17

099918-02

 

Regulator, Pilot

1

18

098271-10

098271-10

 

Ignitor Cable

1

19

107186-01

107186-02

 

Injector

1

20

M11084-26

M11084-26

 

Screw, Hex Head, #10 x 3/8"

25

21

098249-01

098249-01

 

Nut, M5

6

22

103781-02

103781-01

 

Gas Valve

1

23

102639-01

102639-01

 

Baffle

1

24

101628-01

101628-01

 

Flexible Connector

1

25

104305-01

104305-01

 

Control Shield

1

26

103295-03CK

103295-03CK

 

Screen Assembly

1

27

107153-01

107153-01

 

Log Set Assembly Kit

1

28

104313-01

104313-01

 

Right Hinge

1

29

104313-02

104313-02

 

Left Hinge

1

30

M10908-2

M10908-2

 

Hinge Screws

4

31

103734-01

103734-01

 

Burner Support

2

32

101006-02

101006-02

 

Pilot Bracket

1

33

097809-02

097809-02

 

Connector, Male

1

34

101629-01

101629-01

 

Bushing

1

35

101629-02

101629-02

 

Bushing

1

36

M12461-26

M12461-26

 

Gas Valve Screws

4

37

103587-02

103587-02

 

Plate, Switch

1

38

099998-01

099998-01

 

Switch, Fan

1

39

098264-02

098264-02

 

Connector, Male

1

40

103284-03

103284-03

 

Wire Harness

1

41

099387-14

 

Pilot Tube to Regulator

1

42

099387-13

099387-15

 

Pilot Tube to Control Valve

1

43

___

107634-02

 

NG Conversion Plate

1

44

M10908-75

M10908-75

 

Hex Wsr Head Tapping Screw

1

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

103877-01

103877-01

 

Lighting Instructions Plate

1

 

100563-01

100563-01

 

Warning Plate

1

 

103470-02

103470-02

 

Hardware Package

1

 

 

 

 

 

 

** Part not available for field replacement.

113110-01A

www.desatech.com

35

Image 35
Contents REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRA Shown with optional cabinet mantel/hearth base accessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationLocal Codes Optional Remote Control AccessoriesProduct Features AssemblyUnusually Tight Construction Assembly AIR for Combustion VentilationProviding Adequate Ventilation Determining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Confined and Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items Minimum 16 inches from Side Wall BUILT-IN Fireplace InstallationFireplace Clearances Minimum Clearance to Combustible MaterialsRough Opening for Installing Wall Mantel Clearances for Built-In Installation Optional Mantel InstallationAssemblingTrimTrimshippedwithmantel Installing Optional Blower Accessory GA3450TRemoving Upper Louver Assembly and Branch Support Installing Blower Accessory Extension Cord For Built-In InstallationTest to make sure the blower is working properly External Regulator With Vent Pointing Down Connecting to GAS SupplyPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Correct all leaks at once Pressure Testing gas Supply Piping SystemChecking GAS Connections Installing Receiver Pressure Testing Fireplace Gas ConnectionsOptional Wall Mounted Wire harness provided in the fireplace hard- ware packInstalling 9-Volt Battery in Hand-Held Remote Control Unit Remove battery cover on back of remote con- trol unitInstall the base onto the wall with the pro- vided screws Optional Wall Switch GWMS2Installing LOG SET and Screen Operating Fireplace For Your Safety Read Before LightingSelector Switch OFF Position Control Knob Ignitor Button Flame Adjustment KnobShutting Off Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationThermostat Series Model Ghrctb ON/OFF Series Model GhrcbOperating Blower Optional GWMS2 Wall Mounted Switch OptionalInspecting Burners GWMT1 Wall Mounted Thermostat OptionalBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Air Passageways Wiring DiagramLOG SET CabinetIgnitor cable dry TroubleshootingObserved Problem Possible Cause Remedy Replace pilot assemblyPressed Safety interlock system hasLow gas pressure ODS/pilot assembly Or improperly connected Diagram,Hours of operation Bris. If found, clean burnerResidues from manufactur Tial operationGas leak. See Warning Remote-Ready Models SpecificationsParts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown REMOTE-READY Models Parts ListTHERMOSTAT-CONTROLLED Blower KIT GA3450T AccessoriesEquipment Shutoff Valve GA5010 Perimeter Trim KIT GA6095Information Video Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb Cabinet Mantel and Full Hearth BasePage Page Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty InformationKeep this Warranty