Desa VMH26NRB, EFS26NRA, EFS26PRA, VMH26PRB installation manual Safety Information

Page 3

SAFETY INFORMATION

WARNING: This product con- tains and/or generates chemi- cals known to the State of Cali- fornia to cause cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate, or service this fireplace. Im- proper use of this fireplace can cause serious injury or death from burns, fire, explosion, elec- trical shock, and carbon mon- oxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of car- bon monoxide poisoning resemble the flu, with head- aches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/ LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warn- ings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger in- sert, or other accessory not ap- proved for use with this fireplace.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out of traffic and away from furni- ture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen be- come very hot when running heater. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace withthefireplacescreeninplace. Make sure fireplace screen is closed before running fireplace.

Keep the appliance area clear and free from combustible ma- terials, gasoline, and other flam- mable vapors and liquids.

113110-01A

www.desatech.com

3

Image 3
Contents REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRA Shown with optional cabinet mantel/hearth base accessoryTable of Contents Safety Information Provide adequate clearances around air openings Product IdentificationLocal Codes Optional Remote Control AccessoriesProduct Features AssemblyAssembly AIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Determining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Confined and Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Installation ItemsCheck GAS Type Minimum 16 inches from Side Wall BUILT-IN Fireplace InstallationFireplace Clearances Minimum Clearance to Combustible MaterialsRough Opening for Installing Wall Mantel Clearances for Built-In Installation Optional Mantel InstallationInstalling Optional Blower Accessory GA3450T Removing Upper Louver Assembly and Branch SupportAssemblingTrimTrimshippedwithmantel Installing Blower Accessory For Built-In Installation Test to make sure the blower is working properlyExtension Cord External Regulator With Vent Pointing Down Connecting to GAS SupplyConnecting Fireplace to GAS Supply Installation Items NeededPropane/LP Pressure Testing gas Supply Piping System Checking GAS ConnectionsCorrect all leaks at once Installing Receiver Pressure Testing Fireplace Gas ConnectionsOptional Wall Mounted Wire harness provided in the fireplace hard- ware packInstalling 9-Volt Battery in Hand-Held Remote Control Unit Remove battery cover on back of remote con- trol unitOptional Wall Switch GWMS2 Installing LOG SET and ScreenInstall the base onto the wall with the pro- vided screws Operating Fireplace For Your Safety Read Before LightingSelector Switch OFF Position Control Knob Ignitor Button Flame Adjustment KnobShutting Off Fireplace Manual Lighting ProcedureTo Turn OFF GAS To Appliance Optional HAND-HELD Remote OperationThermostat Series Model Ghrctb ON/OFF Series Model GhrcbOperating Blower Optional GWMS2 Wall Mounted Switch OptionalInspecting Burners GWMT1 Wall Mounted Thermostat OptionalCleaning Maintenance Burner Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Air Passageways Wiring DiagramLOG SET CabinetIgnitor cable dry TroubleshootingObserved Problem Possible Cause Remedy Replace pilot assemblyPressed Safety interlock system hasLow gas pressure ODS/pilot assembly Or improperly connected Diagram,Hours of operation Bris. If found, clean burnerResidues from manufactur Tial operationGas leak. See Warning Remote-Ready Models SpecificationsParts Under Warranty Replacement PartsService Hints Technical ServiceIllustrated Parts Breakdown REMOTE-READY Models Parts ListTHERMOSTAT-CONTROLLED Blower KIT GA3450T AccessoriesEquipment Shutoff Valve GA5010 Perimeter Trim KIT GA6095Information Video Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb Cabinet Mantel and Full Hearth BasePage Page Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Compact Classic Hearth Fireplace