Desa EFS26NRA, EFS26PRA, VMH26PRB, VMH26NRB installation manual Specifications, Remote-Ready Models

Page 32

SPECIFICATIONS

 

Remote-Ready Models

Remote-Ready Models

 

VMH26PRB, EFS26PRA

VMH26NRB, EFS26NRA

Btu/Hr

14,000/26,000

14,000/26,000

Type Gas

Propane/LP Gas Only

Natural Gas Only

Ignition

Piezo

Piezo

Manifold Pressure

8" W.C.

3.5" W.C.

Inlet Gas Pressure

 

 

(in. of water)

 

 

Maximum

14"

10.5"

Minimum*

11"

5"

Dimensions, inches (HxWxD)

 

 

Fireplace

25 7/8 x 26 13/16 x 9 3/8

25 7/8 x 26 13/16 x 9 3/8

(including hood

 

 

and screws)

 

 

Carton

32 5/8 x 27 13/16 x 11 5/8

32 5/8 x 27 13/16 x 11 5/8

Weight, pounds

 

 

Fireplace

44 1/2 lbs.

44 1/2 lbs.

Shipping

48 lbs.

48 lbs.

* For purpose of input adjustment

32

www.desatech.com

113110-01A

Image 32
Contents Shown with optional cabinet mantel/hearth base accessory REMOTE-READY Models VMH26PRB, VMH26NRB, EFS26NRA, EFS26PRATable of Contents Safety Information Product Identification Provide adequate clearances around air openingsOptional Remote Control Accessories Product FeaturesAssembly Local CodesUnusually Tight Construction Assembly AIR for Combustion VentilationProviding Adequate Ventilation AIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationConfined and Unconfined Space Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Items BUILT-IN Fireplace Installation Fireplace ClearancesMinimum Clearance to Combustible Materials Minimum 16 inches from Side WallRough Opening for Installing Wall Optional Mantel Installation Mantel Clearances for Built-In InstallationAssemblingTrimTrimshippedwithmantel Installing Optional Blower Accessory GA3450TRemoving Upper Louver Assembly and Branch Support Installing Blower Accessory Extension Cord For Built-In InstallationTest to make sure the blower is working properly Connecting to GAS Supply External Regulator With Vent Pointing DownPropane/LP Connecting Fireplace to GAS SupplyInstallation Items Needed Correct all leaks at once Pressure Testing gas Supply Piping SystemChecking GAS Connections Pressure Testing Fireplace Gas Connections Installing ReceiverWire harness provided in the fireplace hard- ware pack Installing 9-Volt Battery in Hand-Held Remote Control UnitRemove battery cover on back of remote con- trol unit Optional Wall MountedInstall the base onto the wall with the pro- vided screws Optional Wall Switch GWMS2Installing LOG SET and Screen For Your Safety Read Before Lighting Selector Switch OFF Position Control KnobIgnitor Button Flame Adjustment Knob Operating FireplaceManual Lighting Procedure To Turn OFF GAS To ApplianceOptional HAND-HELD Remote Operation Shutting Off FireplaceON/OFF Series Model Ghrcb Thermostat Series Model GhrctbGWMS2 Wall Mounted Switch Optional Inspecting BurnersGWMT1 Wall Mounted Thermostat Optional Operating Blower OptionalBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Flame Pattern Wiring Diagram LOG SETCabinet Air PassagewaysTroubleshooting Observed Problem Possible Cause RemedyReplace pilot assembly Ignitor cable drySafety interlock system has Low gas pressure ODS/pilot assemblyOr improperly connected Diagram, PressedBris. If found, clean burner Residues from manufacturTial operation Hours of operationGas leak. See Warning Specifications Remote-Ready ModelsReplacement Parts Service HintsTechnical Service Parts Under WarrantyIllustrated Parts Breakdown Parts List REMOTE-READY ModelsAccessories Equipment Shutoff Valve GA5010Perimeter Trim KIT GA6095 THERMOSTAT-CONTROLLED Blower KIT GA3450TReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbCabinet Mantel and Full Hearth Base Information VideoPage Page Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty InformationKeep this Warranty